Manufacturer: ZNSHINE PV-TECH Co Ltd Registry: CEC Verified Engineering Specification

ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M is a 290.0 W STC (268.8 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 17.68% efficiency, 38.86 V Voc at 25 C, and 42.49 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
268.8 W
Voc @ 25C
38.86 V
Efficiency
17.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M (Mono-c-Si) residential solar systems.

Homeowners evaluating ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M need 21 panels for 6 kW or 28 panels (494 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (494 sq ft). Under NEC 690.7(A), beta_Voc (-0.267%/C) pushes open-circuit voltage to 42.49 V at 14 F and 43.53 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M Fall Across Listed CEC Models?

Comparison of ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZNSHINE PV-TECH Co: 290.0 W

What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M?

Relative ranking of ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency.

ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M Engineering BenchmarksPercentile comparison of ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention92.7%Module Efficiency17.68%

What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M?

Summary of ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,541

17.68% Aperture Efficiency

Power density 176.8 W/m2 (2.23 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.49 V at -10 C (594.9 V string) and 43.53 V at -20 C (13 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 45.9 m2 (494 sq ft) producing 7,526 W PTC; NEC 690.8 OCPD floor is 15.07 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.86 * (1 + (-0.267/100) * (-10 - 25)) = 42.49 V | OCPD = 1.56 * 9.66 = 15.07 A

Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M: Voc=38.86 V, beta_Voc=-0.267%/C, Isc=9.66 A, STC=290.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (594.9 V); 28 panels for 8 kW (494 sq ft).

What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M?

Complete CEC test sheet for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M including Isc (9.66 A), Voc (38.86 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 268.8 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.86 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.66 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.16 V / 9.02 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.267 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.68% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 371 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 494 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 618 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This ZNSHINE PV-TECH Co Ltd Series?

Related ZNSHINE PV-TECH Co Ltd power steps and black/silver trims consolidated into this ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M series guide.

Sibling CEC listings grouped into the ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
ZNSHINE PV-TECH Co Ltd ZXM6-60-285/M 285.0 W 264.1 W 38.59 V 31.85 V 17.38%
ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M 290.0 W 268.8 W 38.86 V 32.16 V 17.68%
ZNSHINE PV-TECH Co Ltd ZXM6-60-295/M 295.0 W 271.4 W 39.5 V 32.3 V 17.88%

How Many ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M (38.86 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.86V and beta_Voc=-0.267%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.53 V 13 panels 565.9 V 22 panels
-10 C (14 F) 42.49 V 14 panels 594.9 V 23 panels
0 C (32 F) 41.45 V 14 panels 580.3 V 24 panels
25 C (77 F STC) 38.86 V 15 panels 582.9 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M?

Four comparable CEC modules such as CertainTeed CT290M10-01 (290.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CT290M10-01
CertainTeed
290.0 W Tie (0 W) 38.8 V 17.72% 90.9%
CertainTeed CT290M11-01
CertainTeed
290.0 W Tie (0 W) 38.8 V 17.72% 90.6%
GCL System Integration Technology Co Ltd GCL-M6/60290
GCL System Integration Technology Co Ltd
290.0 W Tie (0 W) 39.1 V 17.79% 90.2%
GCL System Integration Technology Co Ltd GCL-P6/60290
GCL System Integration Technology Co Ltd
290.0 W Tie (0 W) 39.1 V 17.79% 90.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M?

Evaluate ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M (290.0 W STC, 38.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M reaches 43.53 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 494 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (494 sq ft).
  • 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M 8 kW Residential Fit

Needs 28 modules (494 sq ft) with a 20 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CT290M10-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 268.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M PTC wattage (268.8 W) lower than STC (290.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 268.8 W PTC (92.7% retention) across ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M's 1.64 m2 aperture.

Who should skip ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M panels (494 sq ft) leave unusable roof gaps vs. CertainTeed CT290M10-01.

What is the 1,000 V commercial string limit for ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M?

On 1,000 V commercial inverters at -10 C (42.49 V cold Voc), ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M fits up to 23 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.