Vikram Solar SOMERA VSMHBB6037005 — CEC Solar Module Specifications

Manufacturer: Vikram Solar Registry: CEC Verified Engineering Specification

Vikram Solar SOMERA VSMHBB6037005 is a 370.0 W STC (341.9 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 19.89% efficiency, 41.1 V Voc at 25 C, and 45.24 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
341.9 W
Voc @ 25C
41.1 V
Efficiency
19.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Vikram Solar SOMERA VSMHBB6037005 Compare Against Peer CEC Listings?

Engineering position of Vikram Solar SOMERA VSMHBB6037005 (370.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W across 5,889 CEC Mono-c-Si solar modules.

Ranking #11,697 across 21,677 CEC solar panels (below all-CEC median; higher than 44.4% of peers), Vikram Solar SOMERA VSMHBB6037005 operates as a compact residential or specialty off-grid module sitting 40.0 W below the 410.0 W Mono-c-Si median. Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677), 22 panels occupy 440 sq ft and offset roughly $2,037/yr at average US rates (or $3,445/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Vikram Solar SOMERA VSMHBB6037005 Fall Across Listed CEC Models?

Plots Vikram Solar SOMERA VSMHBB6037005 at 370.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Vikram Solar SOMERA VSMHBB6037005 (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVikram Solar SOMER: 370.0 W

What Dataset Percentiles Define Vikram Solar SOMERA VSMHBB6037005?

Benchmarks Vikram Solar SOMERA VSMHBB6037005 on STC wattage, thermal PTC/STC retention, and 19.89 aperture conversion efficiency against CEC peers.

Vikram Solar SOMERA VSMHBB6037005 Engineering BenchmarksPercentile comparison of Vikram Solar SOMERA VSMHBB6037005 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention92.4%Module Efficiency19.89%

What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMHBB6037005?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Vikram Solar SOMERA VSMHBB6037005 by Vikram Solar.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,917

19.89% Aperture Efficiency

Power density 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.24 V at -10 C (588.1 V string) and 46.43 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,522 W PTC; NEC 690.8 OCPD floor is 18.02 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.1 * (1 + (-0.288/100) * (-10 - 25)) = 45.24 V | OCPD = 1.56 * 11.55 = 18.02 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMHBB6037005: Voc=41.1 V, beta_Voc=-0.288%/C, Isc=11.55 A, STC=370.0 W, Area=1.86 m2.

Result: 13 panels max on 600 V (588.1 V); 22 panels for 8 kW (440 sq ft).

What Are the Published CEC Specifications for Vikram Solar SOMERA VSMHBB6037005?

Laboratory test ratings recorded for Vikram Solar SOMERA VSMHBB6037005 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSMHBB6037005.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 341.9 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.9 V / 10.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.288 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.89% (1.86 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Vikram Solar SOMERA VSMHBB6037005 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (440 sq ft at 8 kW), and estimated Year-1 electric bill offset for Vikram Solar SOMERA VSMHBB6037005.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 340 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 440 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 561 sq ft $2,593 $4,385

How Many Vikram Solar SOMERA VSMHBB6037005 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Vikram Solar SOMERA VSMHBB6037005 (beta_Voc -0.288%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=41.1V and beta_Voc=-0.288%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.43 V 12 panels 557.2 V 21 panels
-10 C (14 F) 45.24 V 13 panels 588.1 V 22 panels
0 C (32 F) 44.06 V 13 panels 572.8 V 22 panels
25 C (77 F STC) 41.1 V 14 panels 575.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMHBB6037005?

Closest cross-brand CEC competitors to Vikram Solar SOMERA VSMHBB6037005 matched near 370.0 W STC and 41.1 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W +5.0 W 41.1 V 21.07% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W +5.0 W 41.1 V 20.72% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W +5.0 W 41.1 V 20.49% 93.4%
AXITEC AC-375MH/120V
AXITEC
375.0 W +5.0 W 41.1 V 20.72% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMHBB6037005?

Evaluate Vikram Solar SOMERA VSMHBB6037005 (370.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMHBB6037005 reaches 46.43 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 440 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (440 sq ft).
  • 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMHBB6037005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Vikram Solar SOMERA VSMHBB6037005 8 kW Residential Fit

Needs 22 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 341.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSMHBB6037005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Vikram Solar SOMERA VSMHBB6037005 panels fit on a 600 V winter solar string?

At -10 C (14 F), Vikram Solar SOMERA VSMHBB6037005 cold Voc rises from 41.1 V to 45.24 V (beta_Voc -0.288%/C), capping a 600 V string at 13 panels (588.1 V).

How much roof area does an 8 kW array of Vikram Solar SOMERA VSMHBB6037005 need?

An 8 kW DC system uses 22 Vikram Solar SOMERA VSMHBB6037005 modules (8,140 W STC / 7,522 W PTC), covering roughly 440 sq ft and saving ~$2,037/yr at 18.54 c/kWh.

How does Vikram Solar SOMERA VSMHBB6037005 compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W?

Vikram Solar SOMERA VSMHBB6037005 outputs 370.0 W STC (41.1 V Voc, rank #11,697 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W delivers 375.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.