Vikram Solar SOMERA VSMH7244505 is a 445.0 W STC (411.8 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 20.23% efficiency, 48.9 V Voc at 25 C, and 51.26 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 445.0 W
- PTC Wattage
- 411.8 W
- Voc @ 25C
- 48.9 V
- Efficiency
- 20.23%
How Does Vikram Solar SOMERA VSMH7244505 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Vikram Solar SOMERA VSMH7244505 (Mono-c-Si) residential solar systems.
Homeowners evaluating Vikram Solar SOMERA VSMH7244505 need 14 panels for 6 kW or 18 panels (426 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (426 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.138%/C) pushes open-circuit voltage to 51.26 V at 14 F and 51.94 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Vikram Solar SOMERA VSMH7244505 Fall Across Listed CEC Models?
Comparison of Vikram Solar SOMERA VSMH7244505 (445.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Vikram Solar SOMERA VSMH7244505?
Relative ranking of Vikram Solar SOMERA VSMH7244505 across nameplate watts, 92.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMH7244505?
Summary of Vikram Solar SOMERA VSMH7244505 output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 29.6% STC Output
445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.23% Aperture Efficiency
Power density 202.3 W/m2 (0.32 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.26 V at -10 C (563.9 V string) and 51.94 V at -20 C (11 max).
18 Panels = 8,010 W STC
Occupies 39.6 m2 (426 sq ft) producing 7,412 W PTC; NEC 690.8 OCPD floor is 18.21 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.9 * (1 + (-0.138/100) * (-10 - 25)) = 51.26 V | OCPD = 1.56 * 11.67 = 18.21 A
Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMH7244505: Voc=48.9 V, beta_Voc=-0.138%/C, Isc=11.67 A, STC=445.0 W, Area=2.2 m2.
Result: 11 panels max on 600 V (563.9 V); 18 panels for 8 kW (426 sq ft).
What Are the Published CEC Specifications for Vikram Solar SOMERA VSMH7244505?
Complete CEC test sheet for Vikram Solar SOMERA VSMH7244505 including Isc (11.67 A), Voc (48.9 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 411.8 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.5 V / 10.72 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.138 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.23% (2.2 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vikram Solar SOMERA VSMH7244505 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Vikram Solar SOMERA VSMH7244505.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.23 kW | 332 sq ft | $1,559 | $2,637 |
| 8 kW Class | 18 | 8.01 kW | 426 sq ft | $2,005 | $3,390 |
| 10 kW Class | 23 | 10.23 kW | 545 sq ft | $2,560 | $4,330 |
How Many Vikram Solar SOMERA VSMH7244505 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Vikram Solar SOMERA VSMH7244505 (48.9 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.94 V | 11 panels | 571.3 V | 19 panels |
| -10 C (14 F) | 51.26 V | 11 panels | 563.9 V | 19 panels |
| 0 C (32 F) | 50.59 V | 11 panels | 556.5 V | 19 panels |
| 25 C (77 F STC) | 48.9 V | 12 panels | 586.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMH7244505?
Four comparable CEC modules such as ELITE Solar ET-M672BH440WW (440.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ELITE Solar ET-M672BH440WW ELITE Solar |
440.0 W | -5.0 W | 48.9 V | 20.47% | 93.5% |
| CSI Solar Co Ltd CS3W-440MS CSI Solar Co Ltd |
440.0 W | -5.0 W | 48.7 V | 20.56% | 93.1% |
| Apollo Renewables Inc Apollo-M672BH-440TW Apollo Renewables Inc |
440.0 W | -5.0 W | 49.2 V | 20.47% | 93.4% |
| Bluesun Solar CoLtd BSM440M-72HPH Bluesun Solar CoLtd |
440.0 W | -5.0 W | 49.2 V | 20.28% | 92.7% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMH7244505?
Evaluate Vikram Solar SOMERA VSMH7244505 (445.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMH7244505 reaches 51.94 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMH7244505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar SOMERA VSMH7244505 8 kW Residential Fit
Needs 18 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare ELITE Solar ET-M672BH440WW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 411.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar SOMERA VSMH7244505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Vikram Solar SOMERA VSMH7244505 PTC wattage (411.8 W) lower than STC (445.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 411.8 W PTC (92.5% retention) across Vikram Solar SOMERA VSMH7244505's 2.2 m2 aperture.
Who should skip Vikram Solar SOMERA VSMH7244505 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Vikram Solar SOMERA VSMH7244505 panels (426 sq ft) leave unusable roof gaps vs. ELITE Solar ET-M672BH440WW.
What is the 1,000 V commercial string limit for Vikram Solar SOMERA VSMH7244505?
On 1,000 V commercial inverters at -10 C (51.26 V cold Voc), Vikram Solar SOMERA VSMH7244505 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Vikram Solar SOMERA VSMH7244505.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)