Skip to main content
WireAndSun
Calculators
CEC PV Module

Vikram Solar SOMERA VSMDT7238505 — CEC Solar Module Specifications

Manufacturer: Vikram Solar Registry: CEC Verified Engineering Specification

Vikram Solar SOMERA VSMDT7238505 is a 385.0 W STC (355.4 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.06% efficiency, 47.3 V Voc at 25 C, and 51.79 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
355.4 W
Voc @ 25C
47.3 V
Efficiency
19.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Vikram Solar SOMERA VSMDT7238505 Compare Against Peer CEC Listings?

How Vikram Solar Vikram Solar SOMERA VSMDT7238505 handles rooftop heat (355.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Vikram Solar SOMERA VSMDT7238505 exhibits 10.19 A short-circuit current, requiring a 15.9 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #10,723 of 21,677 (25.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 42.4 m2 for an 8 kW system (26 panels for 10 kW). Mid-range 47.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Vikram Solar SOMERA VSMDT7238505 Fall Across Listed CEC Models?

Where Vikram Solar SOMERA VSMDT7238505 (385.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Vikram Solar SOMERA VSMDT7238505 (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVikram Solar SOMER: 385.0 W

What Dataset Percentiles Define Vikram Solar SOMERA VSMDT7238505?

Percentile placement of Vikram Solar SOMERA VSMDT7238505 across power density (190.6 W/m2), thermal retention, and nameplate STC wattage.

Vikram Solar SOMERA VSMDT7238505 Engineering BenchmarksPercentile comparison of Vikram Solar SOMERA VSMDT7238505 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention92.3%Module Efficiency19.06%

What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMDT7238505?

Four critical engineering numbers homeowners and solar installers check first when reviewing Vikram Solar SOMERA VSMDT7238505 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,297

19.06% Aperture Efficiency

Power density 190.6 W/m2 (0.85 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.79 V at -10 C (569.7 V string) and 53.07 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 42.4 m2 (457 sq ft) producing 7,463 W PTC; NEC 690.8 OCPD floor is 15.9 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.3 * (1 + (-0.271/100) * (-10 - 25)) = 51.79 V | OCPD = 1.56 * 10.19 = 15.9 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMDT7238505: Voc=47.3 V, beta_Voc=-0.271%/C, Isc=10.19 A, STC=385.0 W, Area=2.02 m2.

Result: 11 panels max on 600 V (569.7 V); 21 panels for 8 kW (457 sq ft).

What Are the Published CEC Specifications for Vikram Solar SOMERA VSMDT7238505?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Vikram Solar SOMERA VSMDT7238505.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSMDT7238505.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 355.4 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.19 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.4 V / 9.53 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.06% (2.02 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Vikram Solar SOMERA VSMDT7238505 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Vikram Solar SOMERA VSMDT7238505 (385.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 348 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 457 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 565 sq ft $2,505 $4,236

How Many Vikram Solar SOMERA VSMDT7238505 Modules Fit in a Cold-Weather String?

Maximum series module counts for Vikram Solar SOMERA VSMDT7238505 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.3V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.07 V 11 panels 583.8 V 18 panels
-10 C (14 F) 51.79 V 11 panels 569.7 V 19 panels
0 C (32 F) 50.5 V 11 panels 555.5 V 19 panels
25 C (77 F STC) 47.3 V 12 panels 567.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMDT7238505?

Alternative CEC solar modules from competing brands near Vikram Solar SOMERA VSMDT7238505 (385.0 W), including CSI Solar Co Ltd CS3U-385MB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-385MB-AG
CSI Solar Co Ltd
385.0 W Tie (0 W) 48.0 V 19.85% 93.9%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.15% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.06% 93.6%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 18.78% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMDT7238505?

Evaluate Vikram Solar SOMERA VSMDT7238505 (385.0 W STC, 47.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMDT7238505 reaches 53.07 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 457 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (457 sq ft).
  • 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMDT7238505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Vikram Solar SOMERA VSMDT7238505 8 kW Residential Fit

Needs 21 modules (457 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-385MB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 355.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSMDT7238505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Vikram Solar SOMERA VSMDT7238505 PTC wattage (355.4 W) lower than STC (385.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 355.4 W PTC (92.3% retention) across Vikram Solar SOMERA VSMDT7238505's 2.02 m2 aperture.

Who should skip Vikram Solar SOMERA VSMDT7238505 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Vikram Solar SOMERA VSMDT7238505 panels (457 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-385MB-AG.

What is the 1,000 V commercial string limit for Vikram Solar SOMERA VSMDT7238505?

On 1,000 V commercial inverters at -10 C (51.79 V cold Voc), Vikram Solar SOMERA VSMDT7238505 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Vikram Solar SOMERA VSMDT7238505.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.