Vikram Solar SOMERA VSM7236505 is a 365.0 W STC (335.7 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 19.41% efficiency, 48.3 V Voc at 25 C, and 53.42 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 335.7 W
- Voc @ 25C
- 48.3 V
- Efficiency
- 19.41%
How Does Vikram Solar SOMERA VSM7236505 Compare Against Peer CEC Listings?
Solar engineering breakdown for Vikram Solar SOMERA VSM7236505: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 365.0 W STC and 335.7 W PTC, Vikram Solar SOMERA VSM7236505 sits -20.0 W vs all-CEC median (below all-CEC median; higher than 42.9% of peers) among 21,677 listed modules. Power density reaches 194.1 W/m2 (0.50 percentage points below 19.91% CEC median). Higher 48.3 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Caterpillar Inc PVC365MP03 rates 365.0 W.
Where Does Vikram Solar SOMERA VSM7236505 Fall Across Listed CEC Models?
Distribution marker showing Vikram Solar SOMERA VSM7236505 (365.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Vikram Solar SOMERA VSM7236505?
Dataset percentiles tracking Vikram Solar SOMERA VSM7236505 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Vikram Solar SOMERA VSM7236505?
Benchmark highlights for Vikram Solar SOMERA VSM7236505 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.41% Aperture Efficiency
Power density 194.1 W/m2 (0.50 percentage points below 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.42 V at -10 C (587.6 V string) and 54.89 V at -20 C (10 max).
22 Panels = 8,030 W STC
Occupies 41.4 m2 (445 sq ft) producing 7,385 W PTC; NEC 690.8 OCPD floor is 15.19 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.3 * (1 + (-0.303/100) * (-10 - 25)) = 53.42 V | OCPD = 1.56 * 9.74 = 15.19 A
Inputs from CEC Modules.csv for Vikram Solar SOMERA VSM7236505: Voc=48.3 V, beta_Voc=-0.303%/C, Isc=9.74 A, STC=365.0 W, Area=1.88 m2.
Result: 11 panels max on 600 V (587.6 V); 22 panels for 8 kW (445 sq ft).
What Are the Published CEC Specifications for Vikram Solar SOMERA VSM7236505?
Official CEC datasheet figures for Vikram Solar SOMERA VSM7236505 (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 335.7 W (92.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.86 V / 9.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.41% (1.88 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vikram Solar SOMERA VSM7236505 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Vikram Solar SOMERA VSM7236505 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 344 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 445 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 567 sq ft | $2,558 | $4,325 |
How Many Vikram Solar SOMERA VSM7236505 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Vikram Solar SOMERA VSM7236505 (53.42 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.89 V | 10 panels | 548.9 V | 18 panels |
| -10 C (14 F) | 53.42 V | 11 panels | 587.6 V | 18 panels |
| 0 C (32 F) | 51.96 V | 11 panels | 571.6 V | 19 panels |
| 25 C (77 F STC) | 48.3 V | 12 panels | 579.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSM7236505?
Competing CEC solar panels closest to Vikram Solar SOMERA VSM7236505 in nameplate wattage and Voc, starting with Caterpillar Inc PVC365MP03.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVC365MP03 Caterpillar Inc |
365.0 W | Tie (0 W) | 48.13 V | 19.41% | 93.4% |
| CertainTeed CT365M10-03 CertainTeed |
365.0 W | Tie (0 W) | 47.8 V | 18.98% | 91.6% |
| CertainTeed CT365M10-02 CertainTeed |
365.0 W | Tie (0 W) | 47.66 V | 19.39% | 91.9% |
| CertainTeed CT365M11-02 CertainTeed |
365.0 W | Tie (0 W) | 47.66 V | 19.39% | 91.4% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSM7236505?
Evaluate Vikram Solar SOMERA VSM7236505 (365.0 W STC, 48.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSM7236505 reaches 54.89 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (445 sq ft).
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSM7236505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar SOMERA VSM7236505 8 kW Residential Fit
Needs 22 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC365MP03.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 335.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar SOMERA VSM7236505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Vikram Solar SOMERA VSM7236505 panels fit on a 600 V winter solar string?
At -10 C (14 F), Vikram Solar SOMERA VSM7236505 cold Voc rises from 48.3 V to 53.42 V (beta_Voc -0.303%/C), capping a 600 V string at 11 panels (587.6 V).
How much roof area does an 8 kW array of Vikram Solar SOMERA VSM7236505 need?
An 8 kW DC system uses 22 Vikram Solar SOMERA VSM7236505 modules (8,030 W STC / 7,385 W PTC), covering roughly 445 sq ft and saving ~$2,010/yr at 18.54 c/kWh.
How does Vikram Solar SOMERA VSM7236505 compare against Caterpillar Inc PVC365MP03?
Vikram Solar SOMERA VSM7236505 outputs 365.0 W STC (48.3 V Voc, rank #12,044 of 21,677), while Caterpillar Inc PVC365MP03 delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)