Skip to main content
WireAndSun
Calculators
CEC PV Module

Vikram Solar SOMERA VSM7236505 — CEC Solar Module Specifications

Manufacturer: Vikram Solar Registry: CEC Verified Engineering Specification

Vikram Solar SOMERA VSM7236505 is a 365.0 W STC (335.7 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 19.41% efficiency, 48.3 V Voc at 25 C, and 53.42 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
335.7 W
Voc @ 25C
48.3 V
Efficiency
19.41%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Vikram Solar SOMERA VSM7236505 Compare Against Peer CEC Listings?

Solar engineering breakdown for Vikram Solar SOMERA VSM7236505: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 365.0 W STC and 335.7 W PTC, Vikram Solar SOMERA VSM7236505 sits -20.0 W vs all-CEC median (below all-CEC median; higher than 42.9% of peers) among 21,677 listed modules. Power density reaches 194.1 W/m2 (0.50 percentage points below 19.91% CEC median). Higher 48.3 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Caterpillar Inc PVC365MP03 rates 365.0 W.

Where Does Vikram Solar SOMERA VSM7236505 Fall Across Listed CEC Models?

Distribution marker showing Vikram Solar SOMERA VSM7236505 (365.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Vikram Solar SOMERA VSM7236505 (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVikram Solar SOMER: 365.0 W

What Dataset Percentiles Define Vikram Solar SOMERA VSM7236505?

Dataset percentiles tracking Vikram Solar SOMERA VSM7236505 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Vikram Solar SOMERA VSM7236505 Engineering BenchmarksPercentile comparison of Vikram Solar SOMERA VSM7236505 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention92.0%Module Efficiency19.41%

What Do the Dataset Ranks Show for Vikram Solar SOMERA VSM7236505?

Benchmark highlights for Vikram Solar SOMERA VSM7236505 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,393

19.41% Aperture Efficiency

Power density 194.1 W/m2 (0.50 percentage points below 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.42 V at -10 C (587.6 V string) and 54.89 V at -20 C (10 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 41.4 m2 (445 sq ft) producing 7,385 W PTC; NEC 690.8 OCPD floor is 15.19 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.3 * (1 + (-0.303/100) * (-10 - 25)) = 53.42 V | OCPD = 1.56 * 9.74 = 15.19 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSM7236505: Voc=48.3 V, beta_Voc=-0.303%/C, Isc=9.74 A, STC=365.0 W, Area=1.88 m2.

Result: 11 panels max on 600 V (587.6 V); 22 panels for 8 kW (445 sq ft).

What Are the Published CEC Specifications for Vikram Solar SOMERA VSM7236505?

Official CEC datasheet figures for Vikram Solar SOMERA VSM7236505 (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSM7236505.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 335.7 W (92.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.74 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.86 V / 9.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.303 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.41% (1.88 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Vikram Solar SOMERA VSM7236505 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Vikram Solar SOMERA VSM7236505 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 344 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 445 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 567 sq ft $2,558 $4,325

How Many Vikram Solar SOMERA VSM7236505 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Vikram Solar SOMERA VSM7236505 (53.42 V at 14 F).

Computed from Voc=48.3V and beta_Voc=-0.303%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.89 V 10 panels 548.9 V 18 panels
-10 C (14 F) 53.42 V 11 panels 587.6 V 18 panels
0 C (32 F) 51.96 V 11 panels 571.6 V 19 panels
25 C (77 F STC) 48.3 V 12 panels 579.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSM7236505?

Competing CEC solar panels closest to Vikram Solar SOMERA VSM7236505 in nameplate wattage and Voc, starting with Caterpillar Inc PVC365MP03.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC365MP03
Caterpillar Inc
365.0 W Tie (0 W) 48.13 V 19.41% 93.4%
CertainTeed CT365M10-03
CertainTeed
365.0 W Tie (0 W) 47.8 V 18.98% 91.6%
CertainTeed CT365M10-02
CertainTeed
365.0 W Tie (0 W) 47.66 V 19.39% 91.9%
CertainTeed CT365M11-02
CertainTeed
365.0 W Tie (0 W) 47.66 V 19.39% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSM7236505?

Evaluate Vikram Solar SOMERA VSM7236505 (365.0 W STC, 48.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSM7236505 reaches 54.89 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (445 sq ft).
  • 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSM7236505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Vikram Solar SOMERA VSM7236505 8 kW Residential Fit

Needs 22 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC365MP03.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 335.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSM7236505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Vikram Solar SOMERA VSM7236505 panels fit on a 600 V winter solar string?

At -10 C (14 F), Vikram Solar SOMERA VSM7236505 cold Voc rises from 48.3 V to 53.42 V (beta_Voc -0.303%/C), capping a 600 V string at 11 panels (587.6 V).

How much roof area does an 8 kW array of Vikram Solar SOMERA VSM7236505 need?

An 8 kW DC system uses 22 Vikram Solar SOMERA VSM7236505 modules (8,030 W STC / 7,385 W PTC), covering roughly 445 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

How does Vikram Solar SOMERA VSM7236505 compare against Caterpillar Inc PVC365MP03?

Vikram Solar SOMERA VSM7236505 outputs 365.0 W STC (48.3 V Voc, rank #12,044 of 21,677), while Caterpillar Inc PVC365MP03 delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.