Vikram Solar SOMERA VSM7236005 is a 360.0 W STC (330.9 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.15% efficiency, 48.1 V Voc at 25 C, and 53.2 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 330.9 W
- Voc @ 25C
- 48.1 V
- Efficiency
- 19.15%
How Does Vikram Solar SOMERA VSM7236005 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Vikram Solar SOMERA VSM7236005 (Mono-c-Si) residential solar systems.
Vikram Solar SOMERA VSM7236005 delivers 191.5 W/m2 (0.76 percentage points below 19.91% CEC median) and strong 91.9% PTC-to-STC heat retention (#14,464 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (465 sq ft). At -4 F (-20 C), string voltage climbs to 54.66 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Advance Power API-M360 (360.0 W).
Where Does Vikram Solar SOMERA VSM7236005 Fall Across Listed CEC Models?
Comparison of Vikram Solar SOMERA VSM7236005 (360.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Vikram Solar SOMERA VSM7236005?
Relative ranking of Vikram Solar SOMERA VSM7236005 across nameplate watts, 91.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Vikram Solar SOMERA VSM7236005?
Summary of Vikram Solar SOMERA VSM7236005 output rank, 8 kW array size (23 panels), efficiency rating, and 600 V string limit.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.15% Aperture Efficiency
Power density 191.5 W/m2 (0.76 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.2 V at -10 C (585.2 V string) and 54.66 V at -20 C (10 max).
23 Panels = 8,280 W STC
Occupies 43.2 m2 (465 sq ft) producing 7,611 W PTC; NEC 690.8 OCPD floor is 15.04 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.1 * (1 + (-0.303/100) * (-10 - 25)) = 53.2 V | OCPD = 1.56 * 9.64 = 15.04 A
Inputs from CEC Modules.csv for Vikram Solar SOMERA VSM7236005: Voc=48.1 V, beta_Voc=-0.303%/C, Isc=9.64 A, STC=360.0 W, Area=1.88 m2.
Result: 11 panels max on 600 V (585.2 V); 23 panels for 8 kW (465 sq ft).
What Are the Published CEC Specifications for Vikram Solar SOMERA VSM7236005?
Complete CEC test sheet for Vikram Solar SOMERA VSM7236005 including Isc (9.64 A), Voc (48.1 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 330.9 W (91.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.73 V / 9.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.15% (1.88 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vikram Solar SOMERA VSM7236005 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Vikram Solar SOMERA VSM7236005.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 344 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 465 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 567 sq ft | $2,523 | $4,266 |
How Many Vikram Solar SOMERA VSM7236005 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Vikram Solar SOMERA VSM7236005 (48.1 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.66 V | 10 panels | 546.6 V | 18 panels |
| -10 C (14 F) | 53.2 V | 11 panels | 585.2 V | 18 panels |
| 0 C (32 F) | 51.74 V | 11 panels | 569.1 V | 19 panels |
| 25 C (77 F STC) | 48.1 V | 12 panels | 577.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSM7236005?
Four comparable CEC modules such as Advance Power API-M360 (360.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-M360 Advance Power |
360.0 W | Tie (0 W) | 47.56 V | 18.56% | 91.7% |
| Auxin Solar AXN6M612T360 Auxin Solar |
360.0 W | Tie (0 W) | 47.56 V | 18.55% | 91.7% |
| Boviet Solar Technology Co Ltd BVM6612M-360 Boviet Solar Technology Co Ltd |
360.0 W | Tie (0 W) | 47.5 V | 18.56% | 92.3% |
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSM7236005?
Evaluate Vikram Solar SOMERA VSM7236005 (360.0 W STC, 48.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSM7236005 reaches 54.66 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 465 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (465 sq ft).
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSM7236005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar SOMERA VSM7236005 8 kW Residential Fit
Needs 23 modules (465 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Advance Power API-M360.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 330.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar SOMERA VSM7236005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Vikram Solar SOMERA VSM7236005 panels fit on a 600 V winter solar string?
At -10 C (14 F), Vikram Solar SOMERA VSM7236005 cold Voc rises from 48.1 V to 53.2 V (beta_Voc -0.303%/C), capping a 600 V string at 11 panels (585.2 V).
How much roof area does an 8 kW array of Vikram Solar SOMERA VSM7236005 need?
An 8 kW DC system uses 23 Vikram Solar SOMERA VSM7236005 modules (8,280 W STC / 7,611 W PTC), covering roughly 465 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does Vikram Solar SOMERA VSM7236005 compare against Advance Power API-M360?
Vikram Solar SOMERA VSM7236005 outputs 360.0 W STC (48.1 V Voc, rank #12,385 of 21,677), while Advance Power API-M360 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)