Vikram Solar PREXOS VSMDHT6037505 is a 375.0 W STC (335.7 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.16% efficiency, 41.1 V Voc at 25 C, and 46.51 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 335.7 W
- Voc @ 25C
- 41.1 V
- Efficiency
- 20.16%
How Does Vikram Solar PREXOS VSMDHT6037505 Compare Against Peer CEC Listings?
Solar engineering breakdown for Vikram Solar PREXOS VSMDHT6037505: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 375.0 W STC and 335.7 W PTC, Vikram Solar PREXOS VSMDHT6037505 sits -10.0 W vs all-CEC median (below all-CEC median; higher than 46.0% of peers) among 21,677 listed modules. Power density reaches 201.6 W/m2 (0.25 percentage points above 19.91% CEC median). Mid-range 41.1 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 21 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF rates 380.0 W.
Where Does Vikram Solar PREXOS VSMDHT6037505 Fall Across Listed CEC Models?
Distribution marker showing Vikram Solar PREXOS VSMDHT6037505 (375.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Vikram Solar PREXOS VSMDHT6037505?
Dataset percentiles tracking Vikram Solar PREXOS VSMDHT6037505 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Vikram Solar PREXOS VSMDHT6037505?
Benchmark highlights for Vikram Solar PREXOS VSMDHT6037505 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.16% Aperture Efficiency
Power density 201.6 W/m2 (0.25 percentage points above 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.51 V at -10 C (558.1 V string) and 48.05 V at -20 C (12 max).
22 Panels = 8,250 W STC
Occupies 40.9 m2 (440 sq ft) producing 7,385 W PTC; NEC 690.8 OCPD floor is 18.17 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.1 * (1 + (-0.376/100) * (-10 - 25)) = 46.51 V | OCPD = 1.56 * 11.65 = 18.17 A
Inputs from CEC Modules.csv for Vikram Solar PREXOS VSMDHT6037505: Voc=41.1 V, beta_Voc=-0.376%/C, Isc=11.65 A, STC=375.0 W, Area=1.86 m2.
Result: 12 panels max on 600 V (558.1 V); 22 panels for 8 kW (440 sq ft).
What Are the Published CEC Specifications for Vikram Solar PREXOS VSMDHT6037505?
Official CEC datasheet figures for Vikram Solar PREXOS VSMDHT6037505 (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 335.7 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.9 V / 10.75 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.376 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.16% (1.86 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Vikram Solar PREXOS VSMDHT6037505 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Vikram Solar PREXOS VSMDHT6037505 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 320 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 440 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 541 sq ft | $2,533 | $4,283 |
How Many Vikram Solar PREXOS VSMDHT6037505 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Vikram Solar PREXOS VSMDHT6037505 (46.51 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.05 V | 12 panels | 576.6 V | 20 panels |
| -10 C (14 F) | 46.51 V | 12 panels | 558.1 V | 21 panels |
| 0 C (32 F) | 44.96 V | 13 panels | 584.5 V | 22 panels |
| 25 C (77 F STC) | 41.1 V | 14 panels | 575.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar PREXOS VSMDHT6037505?
Competing CEC solar panels closest to Vikram Solar PREXOS VSMDHT6037505 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF Boviet Solar Technology Co Ltd |
380.0 W | +5.0 W | 40.94 V | 20.32% | 94.1% |
| Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF-DG Boviet Solar Technology Co Ltd |
380.0 W | +5.0 W | 40.94 V | 20.32% | 94.3% |
| Aptos Solar Technology LLC DNA-120-BF26-365W Aptos Solar Technology LLC |
365.0 W | -10.0 W | 40.59 V | 20.74% | 92.2% |
| Boviet Solar Technology Co Ltd BVM6610M-365S-H-HC-BF Boviet Solar Technology Co Ltd |
365.0 W | -10.0 W | 40.38 V | 19.52% | 94.0% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar PREXOS VSMDHT6037505?
Evaluate Vikram Solar PREXOS VSMDHT6037505 (375.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar PREXOS VSMDHT6037505 reaches 48.05 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 440 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (440 sq ft).
- 2026 tax credit baseline: cash residential installs of Vikram Solar PREXOS VSMDHT6037505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar PREXOS VSMDHT6037505 8 kW Residential Fit
Needs 22 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 335.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar PREXOS VSMDHT6037505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Vikram Solar PREXOS VSMDHT6037505 panels fit on a 600 V winter solar string?
At -10 C (14 F), Vikram Solar PREXOS VSMDHT6037505 cold Voc rises from 41.1 V to 46.51 V (beta_Voc -0.376%/C), capping a 600 V string at 12 panels (558.1 V).
How much roof area does an 8 kW array of Vikram Solar PREXOS VSMDHT6037505 need?
An 8 kW DC system uses 22 Vikram Solar PREXOS VSMDHT6037505 modules (8,250 W STC / 7,385 W PTC), covering roughly 440 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does Vikram Solar PREXOS VSMDHT6037505 compare against Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF?
Vikram Solar PREXOS VSMDHT6037505 outputs 375.0 W STC (41.1 V Voc, rank #11,367 of 21,677), while Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)