Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW is a 405.0 W STC (375.5 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.35% efficiency, 49.1 V Voc at 25 C, and 53.55 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 375.5 W
- Voc @ 25C
- 49.1 V
- Efficiency
- 20.35%
How Does Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW Compare Against Peer CEC Listings?
Solar engineering breakdown for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Vietnam Sunergy Joint Stock Company and peers, Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW stands 5.0 W below the 410.0 W Mono-c-Si median and strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,522-$2,533/yr in baseline US bill offset. Higher 49.1 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW Fall Across Listed CEC Models?
Distribution marker showing Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW (405.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW?
Dataset percentiles tracking Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW?
Benchmark highlights for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.35% Aperture Efficiency
Power density 203.5 W/m2 (0.44 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.55 V at -10 C (589.0 V string) and 54.82 V at -20 C (10 max).
20 Panels = 8,100 W STC
Occupies 39.8 m2 (428 sq ft) producing 7,510 W PTC; NEC 690.8 OCPD floor is 16.35 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.1 * (1 + (-0.259/100) * (-10 - 25)) = 53.55 V | OCPD = 1.56 * 10.48 = 16.35 A
Inputs from CEC Modules.csv for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW: Voc=49.1 V, beta_Voc=-0.259%/C, Isc=10.48 A, STC=405.0 W, Area=1.99 m2.
Result: 11 panels max on 600 V (589.0 V); 20 panels for 8 kW (428 sq ft).
What Are the Published CEC Specifications for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW?
Official CEC datasheet figures for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 375.5 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.9 V / 9.91 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.259 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.35% (1.99 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 321 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 428 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 536 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Vietnam Sunergy Joint Stock Company Series?
Consolidated Vietnam Sunergy Joint Stock Company wattage variants sharing the Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Vietnam Sunergy Joint Stock Company VSUN400-144MH-BW | 400.0 W | 370.7 W | 48.9 V | 40.7 V | 20.1% |
| Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW | 405.0 W | 375.5 W | 49.1 V | 40.9 V | 20.35% |
How Many Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW (53.55 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.82 V | 10 panels | 548.2 V | 18 panels |
| -10 C (14 F) | 53.55 V | 11 panels | 589.0 V | 18 panels |
| 0 C (32 F) | 52.28 V | 11 panels | 575.1 V | 19 panels |
| 25 C (77 F STC) | 49.1 V | 12 panels | 589.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW?
Competing CEC solar panels closest to Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
405.0 W | Tie (0 W) | 49.1 V | 20.77% | 93.0% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872F 405W Dehui Solar Power (Vietnam) CoLtd |
405.0 W | Tie (0 W) | 49.1 V | 20.77% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
405.0 W | Tie (0 W) | 49.2 V | 21.2% | 92.6% |
| CSI Solar Co Ltd CS3U-405MS CSI Solar Co Ltd |
405.0 W | Tie (0 W) | 49.3 V | 21.09% | 93.0% |
What Are the Design Limits and Best-Fit Uses for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW?
Evaluate Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW (405.0 W STC, 49.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW reaches 54.82 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 428 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (428 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW 8 kW Residential Fit
Needs 20 modules (428 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 375.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW by Vietnam Sunergy Joint Stock Company grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW?
Multiplying Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW's 10.48 A short-circuit current by 1.56 equals 16.35 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.55 V cold Voc at 14 F and handles 10.48 A Isc; string inverters cap Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW at 11 panels on 600 V.
Is Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)