Vietnam Sunergy Joint Stock Company VSUN395-108M-BB is a 395.0 W STC (363.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.36% efficiency, 37.03 V Voc at 25 C, and 41.07 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 363.1 W
- Voc @ 25C
- 37.03 V
- Efficiency
- 20.36%
How Does Vietnam Sunergy Joint Stock Company VSUN395-108M-BB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB (Mono-c-Si) residential solar systems.
Homeowners evaluating Vietnam Sunergy Joint Stock Company VSUN395-108M-BB need 16 panels for 6 kW or 21 panels (439 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.312%/C) pushes open-circuit voltage to 41.07 V at 14 F and 42.23 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Vietnam Sunergy Joint Stock Company VSUN395-108M-BB Fall Across Listed CEC Models?
Comparison of Vietnam Sunergy Joint Stock Company VSUN395-108M-BB (395.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Vietnam Sunergy Joint Stock Company VSUN395-108M-BB?
Relative ranking of Vietnam Sunergy Joint Stock Company VSUN395-108M-BB across nameplate watts, 91.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB?
Summary of Vietnam Sunergy Joint Stock Company VSUN395-108M-BB output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.36% Aperture Efficiency
Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.07 V at -10 C (575.0 V string) and 42.23 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.7 m2 (439 sq ft) producing 7,625 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.03 * (1 + (-0.312/100) * (-10 - 25)) = 41.07 V | OCPD = 1.56 * 13.59 = 21.2 A
Inputs from CEC Modules.csv for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB: Voc=37.03 V, beta_Voc=-0.312%/C, Isc=13.59 A, STC=395.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (575.0 V); 21 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB?
Complete CEC test sheet for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB including Isc (13.59 A), Voc (37.03 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 363.1 W (91.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.03 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.0 V / 12.75 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.36% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vietnam Sunergy Joint Stock Company VSUN395-108M-BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Vietnam Sunergy Joint Stock Company VSUN395-108M-BB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 334 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 439 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 543 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This Vietnam Sunergy Joint Stock Company Series?
Related Vietnam Sunergy Joint Stock Company power steps and black/silver trims consolidated into this Vietnam Sunergy Joint Stock Company VSUN395-108M-BB series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Vietnam Sunergy Joint Stock Company VSUN390-108M-BB | 390.0 W | 358.3 W | 36.84 V | 30.82 V | 20.1% |
| Vietnam Sunergy Joint Stock Company VSUN395-108M-BB | 395.0 W | 363.1 W | 37.03 V | 31.0 V | 20.36% |
How Many Vietnam Sunergy Joint Stock Company VSUN395-108M-BB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB (37.03 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.23 V | 14 panels | 591.2 V | 23 panels |
| -10 C (14 F) | 41.07 V | 14 panels | 575.0 V | 24 panels |
| 0 C (32 F) | 39.92 V | 15 panels | 598.8 V | 25 panels |
| 25 C (77 F STC) | 37.03 V | 16 panels | 592.5 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Vietnam Sunergy Joint Stock Company VSUN395-108M-BB?
Four comparable CEC modules such as Auxin Solar AXN10M395B (395.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M395B Auxin Solar |
395.0 W | Tie (0 W) | 37.03 V | 20.84% | 93.9% |
| Convalt Manufacturing LLC CVLT395-108M-BB Convalt Manufacturing LLC |
395.0 W | Tie (0 W) | 37.03 V | 20.36% | 91.9% |
| Elin Energy (Sirius PV) ELNSM54M-HC-395 Elin Energy (Sirius PV) |
395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.2% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-395 Elin Energy (Sirius PV) |
395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB?
Evaluate Vietnam Sunergy Joint Stock Company VSUN395-108M-BB (395.0 W STC, 37.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vietnam Sunergy Joint Stock Company VSUN395-108M-BB reaches 42.23 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vietnam Sunergy Joint Stock Company VSUN395-108M-BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vietnam Sunergy Joint Stock Company VSUN395-108M-BB 8 kW Residential Fit
Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M395B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 363.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB by Vietnam Sunergy Joint Stock Company grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Vietnam Sunergy Joint Stock Company VSUN395-108M-BB PTC wattage (363.1 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 363.1 W PTC (91.9% retention) across Vietnam Sunergy Joint Stock Company VSUN395-108M-BB's 1.94 m2 aperture.
Who should skip Vietnam Sunergy Joint Stock Company VSUN395-108M-BB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Vietnam Sunergy Joint Stock Company VSUN395-108M-BB panels (439 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M395B.
What is the 1,000 V commercial string limit for Vietnam Sunergy Joint Stock Company VSUN395-108M-BB?
On 1,000 V commercial inverters at -10 C (41.07 V cold Voc), Vietnam Sunergy Joint Stock Company VSUN395-108M-BB fits up to 24 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)