Venus Energy Limited VE-560-60IIMK is a 560.0 W STC (524.7 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 19.72% efficiency, 40.41 V Voc at 25 C, and 44.04 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 560.0 W
- PTC Wattage
- 524.7 W
- Voc @ 25C
- 40.41 V
- Efficiency
- 19.72%
How Does Venus Energy Limited VE-560-60IIMK Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Venus Energy Limited VE-560-60IIMK (Mono-c-Si) residential solar systems.
Homeowners evaluating Venus Energy Limited VE-560-60IIMK need 11 panels for 6 kW or 15 panels (459 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.257%/C) pushes open-circuit voltage to 44.04 V at 14 F and 45.08 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Venus Energy Limited VE-560-60IIMK Fall Across Listed CEC Models?
Comparison of Venus Energy Limited VE-560-60IIMK (560.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Venus Energy Limited VE-560-60IIMK?
Relative ranking of Venus Energy Limited VE-560-60IIMK across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Venus Energy Limited VE-560-60IIMK?
Summary of Venus Energy Limited VE-560-60IIMK output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.
Top 11.8% STC Output
560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.72% Aperture Efficiency
Power density 197.2 W/m2 (0.19 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.04 V at -10 C (572.5 V string) and 45.08 V at -20 C (13 max).
15 Panels = 8,400 W STC
Occupies 42.6 m2 (459 sq ft) producing 7,870 W PTC; NEC 690.8 OCPD floor is 27.24 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.41 * (1 + (-0.257/100) * (-10 - 25)) = 44.04 V | OCPD = 1.56 * 17.46 = 27.24 A
Inputs from CEC Modules.csv for Venus Energy Limited VE-560-60IIMK: Voc=40.41 V, beta_Voc=-0.257%/C, Isc=17.46 A, STC=560.0 W, Area=2.84 m2.
Result: 13 panels max on 600 V (572.5 V); 15 panels for 8 kW (459 sq ft).
What Are the Published CEC Specifications for Venus Energy Limited VE-560-60IIMK?
Complete CEC test sheet for Venus Energy Limited VE-560-60IIMK including Isc (17.46 A), Voc (40.41 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 524.7 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.41 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 17.46 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.68 V / 16.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.257 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.72% (2.84 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Venus Energy Limited VE-560-60IIMK Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Venus Energy Limited VE-560-60IIMK.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.16 kW | 336 sq ft | $1,542 | $2,607 |
| 8 kW Class | 15 | 8.4 kW | 459 sq ft | $2,102 | $3,555 |
| 10 kW Class | 18 | 10.08 kW | 550 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Venus Energy Limited Series?
Related Venus Energy Limited power steps and black/silver trims consolidated into this Venus Energy Limited VE-560-60IIMK series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Venus Energy Limited VE-550-60IIMK | 550.0 W | 515.2 W | 40.06 V | 33.39 V | 19.37% |
| Venus Energy Limited VE-555-60IIMK | 555.0 W | 519.9 W | 40.24 V | 33.54 V | 19.54% |
| Venus Energy Limited VE-560-60IIMK | 560.0 W | 524.7 W | 40.41 V | 33.68 V | 19.72% |
| Venus Energy Limited VE-565-60IIMK | 565.0 W | 529.5 W | 40.58 V | 33.82 V | 19.89% |
| Venus Energy Limited VE-570-60IIMK | 570.0 W | 534.3 W | 40.76 V | 33.97 V | 20.07% |
How Many Venus Energy Limited VE-560-60IIMK Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Venus Energy Limited VE-560-60IIMK (40.41 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.08 V | 13 panels | 586.0 V | 22 panels |
| -10 C (14 F) | 44.04 V | 13 panels | 572.5 V | 22 panels |
| 0 C (32 F) | 43.01 V | 13 panels | 559.1 V | 23 panels |
| 25 C (77 F STC) | 40.41 V | 14 panels | 565.7 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Venus Energy Limited VE-560-60IIMK?
Four comparable CEC modules such as CSI Solar Co Ltd CS7L-585MS-R (585.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS7L-585MS-R CSI Solar Co Ltd |
585.0 W | +25.0 W | 40.7 V | 20.89% | 94.0% |
| Elin Energy (Sirius PV) ELNSM72M-HC-560 Elin Energy (Sirius PV) |
560.0 W | Tie (0 W) | 49.9 V | 21.88% | 94.4% |
| Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 Elin Energy (Sirius PV) |
560.0 W | Tie (0 W) | 49.9 V | 21.88% | 94.4% |
| G-Star Pte Ltd GSD8J60M-595BT G-Star Pte Ltd |
595.0 W | +35.0 W | 41.4 V | 21.17% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Venus Energy Limited VE-560-60IIMK?
Evaluate Venus Energy Limited VE-560-60IIMK (560.0 W STC, 40.41 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Venus Energy Limited VE-560-60IIMK reaches 45.08 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 459 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Venus Energy Limited VE-560-60IIMK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Venus Energy Limited VE-560-60IIMK 8 kW Residential Fit
Needs 15 modules (459 sq ft) with a 30 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS7L-585MS-R.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 524.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Venus Energy Limited VE-560-60IIMK by Venus Energy Limited grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Venus Energy Limited VE-560-60IIMK PTC wattage (524.7 W) lower than STC (560.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 524.7 W PTC (93.7% retention) across Venus Energy Limited VE-560-60IIMK's 2.84 m2 aperture.
Who should skip Venus Energy Limited VE-560-60IIMK on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Venus Energy Limited VE-560-60IIMK panels (459 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS7L-585MS-R.
What is the 1,000 V commercial string limit for Venus Energy Limited VE-560-60IIMK?
On 1,000 V commercial inverters at -10 C (44.04 V cold Voc), Venus Energy Limited VE-560-60IIMK fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Venus Energy Limited VE-560-60IIMK.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)