Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 is a 560.0 W STC (528.5 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.88% efficiency, 49.9 V Voc at 25 C, and 53.99 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 560.0 W
- PTC Wattage
- 528.5 W
- Voc @ 25C
- 49.9 V
- Efficiency
- 21.88%
How Does Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 Compare Against Peer CEC Listings?
Solar engineering breakdown for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Elin Energy (Sirius PV) and peers, Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 stands 150.0 W above the 410.0 W Mono-c-Si median and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Sizing 6 kW (11 panels) to 10 kW (18 panels) yields $1,542-$2,523/yr in baseline US bill offset. Higher 49.9 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 Fall Across Listed CEC Models?
Distribution marker showing Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 (560.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM72M-HC-LV-560?
Dataset percentiles tracking Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560?
Benchmark highlights for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 11.8% STC Output
560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.88% Aperture Efficiency
Power density 218.8 W/m2 (1.97 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.99 V at -10 C (593.9 V string) and 55.15 V at -20 C (10 max).
15 Panels = 8,400 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,928 W PTC; NEC 690.8 OCPD floor is 22.15 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.9 * (1 + (-0.234/100) * (-10 - 25)) = 53.99 V | OCPD = 1.56 * 14.2 = 22.15 A
Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560: Voc=49.9 V, beta_Voc=-0.234%/C, Isc=14.2 A, STC=560.0 W, Area=2.56 m2.
Result: 11 panels max on 600 V (593.9 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560?
Official CEC datasheet figures for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 528.5 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.56 V / 13.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.234 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.88% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.16 kW | 303 sq ft | $1,542 | $2,607 |
| 8 kW Class | 15 | 8.4 kW | 413 sq ft | $2,102 | $3,555 |
| 10 kW Class | 18 | 10.08 kW | 496 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?
Consolidated Elin Energy (Sirius PV) wattage variants sharing the Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM72M-HC-LV-550 | 550.0 W | 518.8 W | 49.7 V | 42.05 V | 21.48% |
| Elin Energy (Sirius PV) ELNSM72M-HC-LV-555 | 555.0 W | 523.6 W | 49.8 V | 42.31 V | 21.68% |
| Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 | 560.0 W | 528.5 W | 49.9 V | 42.56 V | 21.88% |
| Elin Energy (Sirius PV) ELNSM72M-HC-LV-565 | 565.0 W | 533.3 W | 50.0 V | 42.81 V | 22.07% |
| Elin Energy (Sirius PV) ELNSM72M-HC-LV-570 | 570.0 W | 538.1 W | 50.1 V | 43.06 V | 22.27% |
How Many Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 (53.99 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.15 V | 10 panels | 551.5 V | 18 panels |
| -10 C (14 F) | 53.99 V | 11 panels | 593.9 V | 18 panels |
| 0 C (32 F) | 52.82 V | 11 panels | 581.0 V | 18 panels |
| 25 C (77 F STC) | 49.9 V | 12 panels | 598.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM72M-HC-LV-560?
Competing CEC solar panels closest to Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 in nameplate wattage and Voc, starting with Chint New Energy Technology Co Ltd CHSM72N-HC-560.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM72N-HC-560 Chint New Energy Technology Co Ltd |
560.0 W | Tie (0 W) | 50.55 V | 21.71% | 94.6% |
| AIMS Power PV555MONO AIMS Power |
555.0 W | -5.0 W | 49.9 V | 21.26% | 94.1% |
| Global Power Services LLC GP555-72G-182BPM Global Power Services LLC |
555.0 W | -5.0 W | 49.95 V | 21.6% | 94.3% |
| Aptos Solar Technology LLC DNA-144-BF10-555W-DG Aptos Solar Technology LLC |
555.0 W | -5.0 W | 50.0 V | 21.6% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560?
Evaluate Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 (560.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 reaches 55.15 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72N-HC-560.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 528.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Elin Energy (Sirius PV) ELNSM72M-HC-LV-560?
Multiplying Elin Energy (Sirius PV) ELNSM72M-HC-LV-560's 14.2 A short-circuit current by 1.56 equals 22.15 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.99 V cold Voc at 14 F and handles 14.2 A Isc; string inverters cap Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 at 11 panels on 600 V.
Is Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Elin Energy (Sirius PV) ELNSM72M-HC-LV-560 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)