Skip to main content
WireAndSun
Calculators
CEC PV Module

Venus Energy Limited VE-455-60IIMJ — CEC Solar Module Specifications

Manufacturer: Venus Energy Limited Registry: CEC Verified Engineering Specification

Venus Energy Limited VE-455-60IIMJ is a 455.0 W STC (428.1 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 20.97% efficiency, 41.38 V Voc at 25 C, and 45.06 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
428.1 W
Voc @ 25C
41.38 V
Efficiency
20.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Venus Energy Limited VE-455-60IIMJ Compare Against Peer CEC Listings?

Engineering position of Venus Energy Limited VE-455-60IIMJ (455.0 W STC) vs. CertainTeed CTM10455HC11-06 across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, Venus Energy Limited VE-455-60IIMJ pairs strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677) with 41.38 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,706 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CertainTeed CTM10455HC11-06 offers a 455.0 W alternative.

Where Does Venus Energy Limited VE-455-60IIMJ Fall Across Listed CEC Models?

Plots Venus Energy Limited VE-455-60IIMJ at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Venus Energy Limited VE-455-60IIMJ (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVenus Energy Limit: 455.0 W

What Dataset Percentiles Define Venus Energy Limited VE-455-60IIMJ?

Benchmarks Venus Energy Limited VE-455-60IIMJ on STC wattage, thermal PTC/STC retention, and 20.97 aperture conversion efficiency against CEC peers.

Venus Energy Limited VE-455-60IIMJ Engineering BenchmarksPercentile comparison of Venus Energy Limited VE-455-60IIMJ wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention94.1%Module Efficiency20.97%

What Do the Dataset Ranks Show for Venus Energy Limited VE-455-60IIMJ?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Venus Energy Limited VE-455-60IIMJ by Venus Energy Limited.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,536

20.97% Aperture Efficiency

Power density 209.7 W/m2 (1.06 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.06 V at -10 C (585.8 V string) and 46.11 V at -20 C (13 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 39.1 m2 (420 sq ft) producing 7,706 W PTC; NEC 690.8 OCPD floor is 21.72 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.38 * (1 + (-0.254/100) * (-10 - 25)) = 45.06 V | OCPD = 1.56 * 13.92 = 21.72 A

Inputs from CEC Modules.csv for Venus Energy Limited VE-455-60IIMJ: Voc=41.38 V, beta_Voc=-0.254%/C, Isc=13.92 A, STC=455.0 W, Area=2.17 m2.

Result: 13 panels max on 600 V (585.8 V); 18 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for Venus Energy Limited VE-455-60IIMJ?

Laboratory test ratings recorded for Venus Energy Limited VE-455-60IIMJ (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Venus Energy Limited VE-455-60IIMJ.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 428.1 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.38 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.56 V / 13.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.254 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.97% (2.17 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Venus Energy Limited VE-455-60IIMJ Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (420 sq ft at 8 kW), and estimated Year-1 electric bill offset for Venus Energy Limited VE-455-60IIMJ.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 327 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 420 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 514 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Venus Energy Limited Series?

Sibling wattage bins and frame colors grouped with Venus Energy Limited VE-455-60IIMJ under Venus Energy Limited to prevent duplicate spec pages.

Sibling CEC listings grouped into the Venus Energy Limited VE-455-60IIMJ wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Venus Energy Limited VE-450-60IIMJ 450.0 W 423.2 W 41.13 V 34.38 V 20.74%
Venus Energy Limited VE-455-60IIMJ 455.0 W 428.1 W 41.38 V 34.56 V 20.97%
Venus Energy Limited VE-460-60IIMJ 460.0 W 432.9 W 41.61 V 34.82 V 21.2%

How Many Venus Energy Limited VE-455-60IIMJ Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Venus Energy Limited VE-455-60IIMJ (beta_Voc -0.254%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=41.38V and beta_Voc=-0.254%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.11 V 13 panels 599.4 V 21 panels
-10 C (14 F) 45.06 V 13 panels 585.8 V 22 panels
0 C (32 F) 44.01 V 13 panels 572.1 V 22 panels
25 C (77 F STC) 41.38 V 14 panels 579.3 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Venus Energy Limited VE-455-60IIMJ?

Closest cross-brand CEC competitors to Venus Energy Limited VE-455-60IIMJ matched near 455.0 W STC and 41.38 V Voc, led by CertainTeed CTM10455HC11-06.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10455HC11-06
CertainTeed
455.0 W Tie (0 W) 41.33 V 21.06% 93.8%
Energate Energy Inc EG-120L455W
Energate Energy Inc
455.0 W Tie (0 W) 41.33 V 21.26% 93.8%
Energate Enerji retim San A EG-120L455W
Energate Enerji retim San A
455.0 W Tie (0 W) 41.33 V 21.26% 93.8%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.3 V 21.26% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Venus Energy Limited VE-455-60IIMJ?

Evaluate Venus Energy Limited VE-455-60IIMJ (455.0 W STC, 41.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Venus Energy Limited VE-455-60IIMJ reaches 46.11 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Venus Energy Limited VE-455-60IIMJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Venus Energy Limited VE-455-60IIMJ 8 kW Residential Fit

Needs 18 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CTM10455HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 428.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Venus Energy Limited VE-455-60IIMJ by Venus Energy Limited grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Venus Energy Limited VE-455-60IIMJ?

Multiplying Venus Energy Limited VE-455-60IIMJ's 13.92 A short-circuit current by 1.56 equals 21.72 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Venus Energy Limited VE-455-60IIMJ pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.06 V cold Voc at 14 F and handles 13.92 A Isc; string inverters cap Venus Energy Limited VE-455-60IIMJ at 13 panels on 600 V.

Is Venus Energy Limited VE-455-60IIMJ eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Venus Energy Limited VE-455-60IIMJ rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.