Venus Energy Limited VE-390-54IIMJ is a 390.0 W STC (366.5 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.0% efficiency, 36.34 V Voc at 25 C, and 39.57 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 366.5 W
- Voc @ 25C
- 36.34 V
- Efficiency
- 20.0%
How Does Venus Energy Limited VE-390-54IIMJ Compare Against Peer CEC Listings?
How Venus Energy Limited Venus Energy Limited VE-390-54IIMJ handles rooftop heat (366.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Venus Energy Limited VE-390-54IIMJ exhibits 13.65 A short-circuit current, requiring a 21.29 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #10,321 of 21,677 (20.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.9 m2 for an 8 kW system (26 panels for 10 kW). Lower 36.34 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.
Where Does Venus Energy Limited VE-390-54IIMJ Fall Across Listed CEC Models?
Where Venus Energy Limited VE-390-54IIMJ (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Venus Energy Limited VE-390-54IIMJ?
Percentile placement of Venus Energy Limited VE-390-54IIMJ across power density (200.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Venus Energy Limited VE-390-54IIMJ?
Four critical engineering numbers homeowners and solar installers check first when reviewing Venus Energy Limited VE-390-54IIMJ specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.0% Aperture Efficiency
Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 39.57 V at -10 C (593.5 V string) and 40.49 V at -20 C (14 max).
21 Panels = 8,190 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,696 W PTC; NEC 690.8 OCPD floor is 21.29 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.34 * (1 + (-0.254/100) * (-10 - 25)) = 39.57 V | OCPD = 1.56 * 13.65 = 21.29 A
Inputs from CEC Modules.csv for Venus Energy Limited VE-390-54IIMJ: Voc=36.34 V, beta_Voc=-0.254%/C, Isc=13.65 A, STC=390.0 W, Area=1.95 m2.
Result: 15 panels max on 600 V (593.5 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for Venus Energy Limited VE-390-54IIMJ?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Venus Energy Limited VE-390-54IIMJ.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 366.5 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.34 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.28 V / 12.88 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.254 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.0% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Venus Energy Limited VE-390-54IIMJ Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Venus Energy Limited VE-390-54IIMJ (390.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 336 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 441 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 546 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Venus Energy Limited Series?
All closely matched Venus Energy Limited wattages and cosmetic trims sharing the Venus Energy Limited VE-390-54IIMJ architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Venus Energy Limited VE-380-54IIMJ | 380.0 W | 356.9 W | 36.05 V | 30.04 V | 19.49% |
| Venus Energy Limited VE-385-54IIMJ | 385.0 W | 361.7 W | 36.19 V | 30.16 V | 19.74% |
| Venus Energy Limited VE-390-54IIMJ | 390.0 W | 366.5 W | 36.34 V | 30.28 V | 20.0% |
| Venus Energy Limited VE-395-54IIMJ | 395.0 W | 371.3 W | 36.51 V | 30.42 V | 20.26% |
How Many Venus Energy Limited VE-390-54IIMJ Modules Fit in a Cold-Weather String?
Maximum series module counts for Venus Energy Limited VE-390-54IIMJ from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 40.49 V | 14 panels | 566.9 V | 24 panels |
| -10 C (14 F) | 39.57 V | 15 panels | 593.5 V | 25 panels |
| 0 C (32 F) | 38.65 V | 15 panels | 579.8 V | 25 panels |
| 25 C (77 F STC) | 36.34 V | 16 panels | 581.4 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Venus Energy Limited VE-390-54IIMJ?
Alternative CEC solar modules from competing brands near Venus Energy Limited VE-390-54IIMJ (390.0 W), including CSI Solar Co Ltd CS6R-390MS-HL {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6R-390MS-HL {Blk} CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 36.4 V | 20.0% | 94.1% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
390.0 W | Tie (0 W) | 36.45 V | 20.53% | 94.4% |
| Apollo Renewables Inc Apollo-M754BH-390BB Apollo Renewables Inc |
390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| AXITEC AC-390MH/108VB AXITEC |
390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
What Are the Design Limits and Best-Fit Uses for Venus Energy Limited VE-390-54IIMJ?
Evaluate Venus Energy Limited VE-390-54IIMJ (390.0 W STC, 36.34 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Venus Energy Limited VE-390-54IIMJ reaches 40.49 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Venus Energy Limited VE-390-54IIMJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Venus Energy Limited VE-390-54IIMJ 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6R-390MS-HL {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Venus Energy Limited VE-390-54IIMJ by Venus Energy Limited grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Venus Energy Limited VE-390-54IIMJ PTC wattage (366.5 W) lower than STC (390.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 366.5 W PTC (94.0% retention) across Venus Energy Limited VE-390-54IIMJ's 1.95 m2 aperture.
Who should skip Venus Energy Limited VE-390-54IIMJ on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Venus Energy Limited VE-390-54IIMJ panels (441 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6R-390MS-HL {Blk}.
What is the 1,000 V commercial string limit for Venus Energy Limited VE-390-54IIMJ?
On 1,000 V commercial inverters at -10 C (39.57 V cold Voc), Venus Energy Limited VE-390-54IIMJ fits up to 25 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Venus Energy Limited VE-390-54IIMJ.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)