United Renewable Energy Co Ltd FBF415DFG-BB is a 415.0 W STC (391.9 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.28% efficiency, 37.92 V Voc at 25 C, and 41.07 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 391.9 W
- Voc @ 25C
- 37.92 V
- Efficiency
- 21.28%
How Does United Renewable Energy Co Ltd FBF415DFG-BB Compare Against Peer CEC Listings?
How United Renewable Energy Co Ltd United Renewable Energy Co Ltd FBF415DFG-BB handles rooftop heat (391.9 W PTC), 8 kW sizing, and cold winter string voltage.
United Renewable Energy Co Ltd builds the United Renewable Energy Co Ltd FBF415DFG-BB (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF (415.0 W), this model holds strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Lower 37.92 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.82 A overcurrent floor served by a 25 A breaker.
Where Does United Renewable Energy Co Ltd FBF415DFG-BB Fall Across Listed CEC Models?
Where United Renewable Energy Co Ltd FBF415DFG-BB (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define United Renewable Energy Co Ltd FBF415DFG-BB?
Percentile placement of United Renewable Energy Co Ltd FBF415DFG-BB across power density (212.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for United Renewable Energy Co Ltd FBF415DFG-BB?
Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd FBF415DFG-BB specifications.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.28% Aperture Efficiency
Power density 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.07 V at -10 C (575.0 V string) and 41.96 V at -20 C (14 max).
20 Panels = 8,300 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,838 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.92 * (1 + (-0.237/100) * (-10 - 25)) = 41.07 V | OCPD = 1.56 * 13.99 = 21.82 A
Inputs from CEC Modules.csv for United Renewable Energy Co Ltd FBF415DFG-BB: Voc=37.92 V, beta_Voc=-0.237%/C, Isc=13.99 A, STC=415.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (575.0 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for United Renewable Energy Co Ltd FBF415DFG-BB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd FBF415DFG-BB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 391.9 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.92 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.33 V / 13.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.237 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.28% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many United Renewable Energy Co Ltd FBF415DFG-BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd FBF415DFG-BB (415.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 315 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 420 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 525 sq ft | $2,598 | $4,393 |
Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?
All closely matched United Renewable Energy Co Ltd wattages and cosmetic trims sharing the United Renewable Energy Co Ltd FBF415DFG-BB architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| United Renewable Energy Co Ltd FBF405DFG-BB | 405.0 W | 382.2 W | 37.68 V | 31.02 V | 20.77% |
| United Renewable Energy Co Ltd FBF410DFG-BB | 410.0 W | 387.0 W | 37.75 V | 31.14 V | 21.03% |
| United Renewable Energy Co Ltd FBF415DFG-BB | 415.0 W | 391.9 W | 37.92 V | 31.33 V | 21.28% |
| United Renewable Energy Co Ltd FBF420DFG-BB | 420.0 W | 396.7 W | 38.11 V | 31.52 V | 21.54% |
How Many United Renewable Energy Co Ltd FBF415DFG-BB Modules Fit in a Cold-Weather String?
Maximum series module counts for United Renewable Energy Co Ltd FBF415DFG-BB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.96 V | 14 panels | 587.4 V | 23 panels |
| -10 C (14 F) | 41.07 V | 14 panels | 575.0 V | 24 panels |
| 0 C (32 F) | 40.17 V | 14 panels | 562.4 V | 24 panels |
| 25 C (77 F STC) | 37.92 V | 15 panels | 568.8 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd FBF415DFG-BB?
Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd FBF415DFG-BB (415.0 W), including Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF Boviet Solar Technology Co Ltd |
415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF-DG Boviet Solar Technology Co Ltd |
415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| CSI Solar Co Ltd CS6R-410MB CSI Solar Co Ltd |
410.0 W | -5.0 W | 38.0 V | 21.69% | 94.2% |
| CSI Solar Co Ltd CS6R-410MB-HL CSI Solar Co Ltd |
410.0 W | -5.0 W | 38.0 V | 21.69% | 94.2% |
What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd FBF415DFG-BB?
Evaluate United Renewable Energy Co Ltd FBF415DFG-BB (415.0 W STC, 37.92 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd FBF415DFG-BB reaches 41.96 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd FBF415DFG-BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
United Renewable Energy Co Ltd FBF415DFG-BB 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 391.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for United Renewable Energy Co Ltd FBF415DFG-BB by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for United Renewable Energy Co Ltd FBF415DFG-BB?
Multiplying United Renewable Energy Co Ltd FBF415DFG-BB's 13.99 A short-circuit current by 1.56 equals 21.82 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can United Renewable Energy Co Ltd FBF415DFG-BB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.07 V cold Voc at 14 F and handles 13.99 A Isc; string inverters cap United Renewable Energy Co Ltd FBF415DFG-BB at 14 panels on 600 V.
Is United Renewable Energy Co Ltd FBF415DFG-BB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of United Renewable Energy Co Ltd FBF415DFG-BB rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)