Skip to main content
WireAndSun
Calculators
CEC PV Module

United Renewable Energy Co Ltd F6K370H4G-BW — CEC Solar Module Specifications

Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd F6K370H4G-BW is a 370.0 W STC (342.6 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 19.28% efficiency, 48.1 V Voc at 25 C, and 52.65 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
342.6 W
Voc @ 25C
48.1 V
Efficiency
19.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd F6K370H4G-BW Compare Against Peer CEC Listings?

How United Renewable Energy Co Ltd United Renewable Energy Co Ltd F6K370H4G-BW handles rooftop heat (342.6 W PTC), 8 kW sizing, and cold winter string voltage.

United Renewable Energy Co Ltd builds the United Renewable Energy Co Ltd F6K370H4G-BW (Mono-c-Si) as a compact residential or specialty off-grid module delivering 192.8 W/m2 (0.63 percentage points below 19.91% CEC median). Compared against Bluesun Solar Energy Tech CoLtd BSM370M-72 (370.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Higher 48.1 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 15.33 A overcurrent floor served by a 20 A breaker.

Where Does United Renewable Energy Co Ltd F6K370H4G-BW Fall Across Listed CEC Models?

Where United Renewable Energy Co Ltd F6K370H4G-BW (370.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd F6K370H4G-BW (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 370.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd F6K370H4G-BW?

Percentile placement of United Renewable Energy Co Ltd F6K370H4G-BW across power density (192.8 W/m2), thermal retention, and nameplate STC wattage.

United Renewable Energy Co Ltd F6K370H4G-BW Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd F6K370H4G-BW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention92.6%Module Efficiency19.28%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F6K370H4G-BW?

Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd F6K370H4G-BW specifications.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,777

19.28% Aperture Efficiency

Power density 192.8 W/m2 (0.63 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.65 V at -10 C (579.1 V string) and 53.94 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 42.2 m2 (454 sq ft) producing 7,537 W PTC; NEC 690.8 OCPD floor is 15.33 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.1 * (1 + (-0.27/100) * (-10 - 25)) = 52.65 V | OCPD = 1.56 * 9.83 = 15.33 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F6K370H4G-BW: Voc=48.1 V, beta_Voc=-0.27%/C, Isc=9.83 A, STC=370.0 W, Area=1.919 m2.

Result: 11 panels max on 600 V (579.1 V); 22 panels for 8 kW (454 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd F6K370H4G-BW?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd F6K370H4G-BW.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd F6K370H4G-BW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 342.6 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.83 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.6 V / 9.35 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.27 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.28% (1.919 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd F6K370H4G-BW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd F6K370H4G-BW (370.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 351 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 454 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 578 sq ft $2,593 $4,385

How Many United Renewable Energy Co Ltd F6K370H4G-BW Modules Fit in a Cold-Weather String?

Maximum series module counts for United Renewable Energy Co Ltd F6K370H4G-BW from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.1V and beta_Voc=-0.27%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.94 V 11 panels 593.3 V 18 panels
-10 C (14 F) 52.65 V 11 panels 579.1 V 18 panels
0 C (32 F) 51.35 V 11 panels 564.9 V 19 panels
25 C (77 F STC) 48.1 V 12 panels 577.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F6K370H4G-BW?

Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd F6K370H4G-BW (370.0 W), including Bluesun Solar Energy Tech CoLtd BSM370M-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM370M-72
Bluesun Solar Energy Tech CoLtd
370.0 W Tie (0 W) 48.23 V 19.07% 91.9%
CertainTeed CT370M00-04
CertainTeed
370.0 W Tie (0 W) 47.9 V 19.66% 93.2%
Caterpillar Inc PVC370MP03H
Caterpillar Inc
370.0 W Tie (0 W) 48.6 V 19.11% 94.1%
Caterpillar Inc PVC365MP03
Caterpillar Inc
365.0 W -5.0 W 48.13 V 19.41% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F6K370H4G-BW?

Evaluate United Renewable Energy Co Ltd F6K370H4G-BW (370.0 W STC, 48.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F6K370H4G-BW reaches 53.94 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 454 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (454 sq ft).
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F6K370H4G-BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd F6K370H4G-BW 8 kW Residential Fit

Needs 22 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM370M-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 342.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd F6K370H4G-BW by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for United Renewable Energy Co Ltd F6K370H4G-BW?

Multiplying United Renewable Energy Co Ltd F6K370H4G-BW's 9.83 A short-circuit current by 1.56 equals 15.33 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can United Renewable Energy Co Ltd F6K370H4G-BW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.65 V cold Voc at 14 F and handles 9.83 A Isc; string inverters cap United Renewable Energy Co Ltd F6K370H4G-BW at 11 panels on 600 V.

Is United Renewable Energy Co Ltd F6K370H4G-BW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of United Renewable Energy Co Ltd F6K370H4G-BW rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.