Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd F2K405H8G is a 405.0 W STC (375.5 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.35% efficiency, 49.1 V Voc at 25 C, and 53.55 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
375.5 W
Voc @ 25C
49.1 V
Efficiency
20.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd F2K405H8G Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd F2K405H8G (Mono-c-Si) residential solar systems.

Homeowners evaluating United Renewable Energy Co Ltd F2K405H8G need 15 panels for 6 kW or 20 panels (428 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (428 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.259%/C) pushes open-circuit voltage to 53.55 V at 14 F and 54.82 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does United Renewable Energy Co Ltd F2K405H8G Fall Across Listed CEC Models?

Comparison of United Renewable Energy Co Ltd F2K405H8G (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd F2K405H8G (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 405.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd F2K405H8G?

Relative ranking of United Renewable Energy Co Ltd F2K405H8G across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency.

United Renewable Energy Co Ltd F2K405H8G Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd F2K405H8G wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention92.7%Module Efficiency20.35%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F2K405H8G?

Summary of United Renewable Energy Co Ltd F2K405H8G output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,131

20.35% Aperture Efficiency

Power density 203.5 W/m2 (0.44 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.55 V at -10 C (589.0 V string) and 54.82 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 39.8 m2 (428 sq ft) producing 7,510 W PTC; NEC 690.8 OCPD floor is 16.35 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.1 * (1 + (-0.259/100) * (-10 - 25)) = 53.55 V | OCPD = 1.56 * 10.48 = 16.35 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F2K405H8G: Voc=49.1 V, beta_Voc=-0.259%/C, Isc=10.48 A, STC=405.0 W, Area=1.99 m2.

Result: 11 panels max on 600 V (589.0 V); 20 panels for 8 kW (428 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd F2K405H8G?

Complete CEC test sheet for United Renewable Energy Co Ltd F2K405H8G including Isc (10.48 A), Voc (49.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd F2K405H8G.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 375.5 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.48 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.9 V / 9.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.259 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.35% (1.99 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd F2K405H8G Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd F2K405H8G.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 321 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 428 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 536 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

Related United Renewable Energy Co Ltd power steps and black/silver trims consolidated into this United Renewable Energy Co Ltd F2K405H8G series guide.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd F2K405H8G wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
United Renewable Energy Co Ltd F2K400H8G 400.0 W 370.7 W 48.9 V 40.7 V 20.1%
United Renewable Energy Co Ltd F2K405H8G 405.0 W 375.5 W 49.1 V 40.9 V 20.35%

How Many United Renewable Energy Co Ltd F2K405H8G Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for United Renewable Energy Co Ltd F2K405H8G (49.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.1V and beta_Voc=-0.259%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.82 V 10 panels 548.2 V 18 panels
-10 C (14 F) 53.55 V 11 panels 589.0 V 18 panels
0 C (32 F) 52.28 V 11 panels 575.1 V 19 panels
25 C (77 F STC) 49.1 V 12 panels 589.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F2K405H8G?

Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W (405.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
405.0 W Tie (0 W) 49.1 V 20.77% 93.0%
Dehui Solar Power (Vietnam) CoLtd DH-M872F 405W
Dehui Solar Power (Vietnam) CoLtd
405.0 W Tie (0 W) 49.1 V 20.77% 93.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
405.0 W Tie (0 W) 49.2 V 21.2% 92.6%
CSI Solar Co Ltd CS3U-405MS
CSI Solar Co Ltd
405.0 W Tie (0 W) 49.3 V 21.09% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F2K405H8G?

Evaluate United Renewable Energy Co Ltd F2K405H8G (405.0 W STC, 49.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F2K405H8G reaches 54.82 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 428 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (428 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F2K405H8G carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd F2K405H8G 8 kW Residential Fit

Needs 20 modules (428 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 375.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd F2K405H8G by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is United Renewable Energy Co Ltd F2K405H8G PTC wattage (375.5 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 375.5 W PTC (92.7% retention) across United Renewable Energy Co Ltd F2K405H8G's 1.99 m2 aperture.

Who should skip United Renewable Energy Co Ltd F2K405H8G on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 United Renewable Energy Co Ltd F2K405H8G panels (428 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W.

What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd F2K405H8G?

On 1,000 V commercial inverters at -10 C (53.55 V cold Voc), United Renewable Energy Co Ltd F2K405H8G fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.