United Renewable Energy Co Ltd D6L360L4A-P is a 360.0 W STC (335.0 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.09% efficiency, 47.26 V Voc at 25 C, and 51.11 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 335.0 W
- Voc @ 25C
- 47.26 V
- Efficiency
- 18.09%
How Does United Renewable Energy Co Ltd D6L360L4A-P Compare Against Peer CEC Listings?
Engineering position of United Renewable Energy Co Ltd D6L360L4A-P (360.0 W STC) vs. CertainTeed CT360M11-03 across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, United Renewable Energy Co Ltd D6L360L4A-P pairs strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677) with 47.26 V nominal Voc. An 8 kW residential build (8,280 W DC, 7,705 W PTC) saves ~$2,072/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CertainTeed CT360M11-03 offers a 360.0 W alternative.
Where Does United Renewable Energy Co Ltd D6L360L4A-P Fall Across Listed CEC Models?
Plots United Renewable Energy Co Ltd D6L360L4A-P at 360.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define United Renewable Energy Co Ltd D6L360L4A-P?
Benchmarks United Renewable Energy Co Ltd D6L360L4A-P on STC wattage, thermal PTC/STC retention, and 18.09 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for United Renewable Energy Co Ltd D6L360L4A-P?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for United Renewable Energy Co Ltd D6L360L4A-P by United Renewable Energy Co Ltd.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.09% Aperture Efficiency
Power density 180.9 W/m2 (1.82 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.11 V at -10 C (562.2 V string) and 52.22 V at -20 C (11 max).
23 Panels = 8,280 W STC
Occupies 45.8 m2 (493 sq ft) producing 7,705 W PTC; NEC 690.8 OCPD floor is 15.46 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.26 * (1 + (-0.233/100) * (-10 - 25)) = 51.11 V | OCPD = 1.56 * 9.91 = 15.46 A
Inputs from CEC Modules.csv for United Renewable Energy Co Ltd D6L360L4A-P: Voc=47.26 V, beta_Voc=-0.233%/C, Isc=9.91 A, STC=360.0 W, Area=1.99 m2.
Result: 11 panels max on 600 V (562.2 V); 23 panels for 8 kW (493 sq ft).
What Are the Published CEC Specifications for United Renewable Energy Co Ltd D6L360L4A-P?
Laboratory test ratings recorded for United Renewable Energy Co Ltd D6L360L4A-P (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 335.0 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.26 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.91 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.43 V / 9.37 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.09% (1.99 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many United Renewable Energy Co Ltd D6L360L4A-P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (493 sq ft at 8 kW), and estimated Year-1 electric bill offset for United Renewable Energy Co Ltd D6L360L4A-P.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 364 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 493 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 600 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?
Sibling wattage bins and frame colors grouped with United Renewable Energy Co Ltd D6L360L4A-P under United Renewable Energy Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| United Renewable Energy Co Ltd D6L350L4A-P | 350.0 W | 325.4 W | 47.06 V | 38.13 V | 17.59% |
| United Renewable Energy Co Ltd D6L355L4A-P | 355.0 W | 330.2 W | 47.16 V | 38.26 V | 17.84% |
| United Renewable Energy Co Ltd D6L360L4A-P | 360.0 W | 335.0 W | 47.26 V | 38.43 V | 18.09% |
| United Renewable Energy Co Ltd D6L365L4A-P | 365.0 W | 339.7 W | 47.36 V | 38.57 V | 18.34% |
| United Renewable Energy Co Ltd D6L370L4A-P | 370.0 W | 344.5 W | 47.46 V | 38.72 V | 18.59% |
How Many United Renewable Energy Co Ltd D6L360L4A-P Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for United Renewable Energy Co Ltd D6L360L4A-P (beta_Voc -0.233%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.22 V | 11 panels | 574.4 V | 19 panels |
| -10 C (14 F) | 51.11 V | 11 panels | 562.2 V | 19 panels |
| 0 C (32 F) | 50.01 V | 11 panels | 550.1 V | 19 panels |
| 25 C (77 F STC) | 47.26 V | 12 panels | 567.1 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd D6L360L4A-P?
Closest cross-brand CEC competitors to United Renewable Energy Co Ltd D6L360L4A-P matched near 360.0 W STC and 47.26 V Voc, led by CertainTeed CT360M11-03.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT360M11-03 CertainTeed |
360.0 W | Tie (0 W) | 47.4 V | 18.72% | 92.3% |
| AXITEC AC-360M/72S AXITEC |
360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| AXITEC AC-360M/72V AXITEC |
360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |
What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd D6L360L4A-P?
Evaluate United Renewable Energy Co Ltd D6L360L4A-P (360.0 W STC, 47.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd D6L360L4A-P reaches 52.22 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 493 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (493 sq ft).
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd D6L360L4A-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
United Renewable Energy Co Ltd D6L360L4A-P 8 kW Residential Fit
Needs 23 modules (493 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT360M11-03.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 335.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for United Renewable Energy Co Ltd D6L360L4A-P by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for United Renewable Energy Co Ltd D6L360L4A-P?
Multiplying United Renewable Energy Co Ltd D6L360L4A-P's 9.91 A short-circuit current by 1.56 equals 15.46 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can United Renewable Energy Co Ltd D6L360L4A-P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.11 V cold Voc at 14 F and handles 9.91 A Isc; string inverters cap United Renewable Energy Co Ltd D6L360L4A-P at 11 panels on 600 V.
Is United Renewable Energy Co Ltd D6L360L4A-P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of United Renewable Energy Co Ltd D6L360L4A-P rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)