Manufacturer: TSEC Registry: CEC Verified Engineering Specification

TSEC TS72-AMH-440 H1 is a 440.0 W STC (408.5 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.37% efficiency, 48.9 V Voc at 25 C, and 54.21 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
408.5 W
Voc @ 25C
48.9 V
Efficiency
20.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does TSEC TS72-AMH-440 H1 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for TSEC TS72-AMH-440 H1 (Mono-c-Si) residential solar systems.

Homeowners evaluating TSEC TS72-AMH-440 H1 need 14 panels for 6 kW or 19 panels (442 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.31%/C) pushes open-circuit voltage to 54.21 V at 14 F and 55.72 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does TSEC TS72-AMH-440 H1 Fall Across Listed CEC Models?

Comparison of TSEC TS72-AMH-440 H1 (440.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where TSEC TS72-AMH-440 H1 (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTSEC TS72-AMH-440 : 440.0 W

What Dataset Percentiles Define TSEC TS72-AMH-440 H1?

Relative ranking of TSEC TS72-AMH-440 H1 across nameplate watts, 92.8% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

TSEC TS72-AMH-440 H1 Engineering BenchmarksPercentile comparison of TSEC TS72-AMH-440 H1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention92.8%Module Efficiency20.37%

What Do the Dataset Ranks Show for TSEC TS72-AMH-440 H1?

Summary of TSEC TS72-AMH-440 H1 output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,017

20.37% Aperture Efficiency

Power density 203.7 W/m2 (0.46 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.21 V at -10 C (596.3 V string) and 55.72 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 41.0 m2 (442 sq ft) producing 7,762 W PTC; NEC 690.8 OCPD floor is 17.88 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.9 * (1 + (-0.31/100) * (-10 - 25)) = 54.21 V | OCPD = 1.56 * 11.46 = 17.88 A

Inputs from CEC Modules.csv for TSEC TS72-AMH-440 H1: Voc=48.9 V, beta_Voc=-0.31%/C, Isc=11.46 A, STC=440.0 W, Area=2.16 m2.

Result: 11 panels max on 600 V (596.3 V); 19 panels for 8 kW (442 sq ft).

What Are the Published CEC Specifications for TSEC TS72-AMH-440 H1?

Complete CEC test sheet for TSEC TS72-AMH-440 H1 including Isc (11.46 A), Voc (48.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for TSEC TS72-AMH-440 H1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 408.5 W (92.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.1 V / 10.71 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.37% (2.16 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many TSEC TS72-AMH-440 H1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using TSEC TS72-AMH-440 H1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 326 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 442 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 535 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This TSEC Series?

Related TSEC power steps and black/silver trims consolidated into this TSEC TS72-AMH-440 H1 series guide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the TSEC TS72-AMH-440 H1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
TSEC TS72-AMH-435 H1 435.0 W 403.8 W 48.7 V 40.9 V 20.14%
TSEC TS72-AMH-440 H1 440.0 W 408.5 W 48.9 V 41.1 V 20.37%
TSEC TS72-AMH-445 H1 445.0 W 413.3 W 49.1 V 41.3 V 20.6%

How Many TSEC TS72-AMH-440 H1 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for TSEC TS72-AMH-440 H1 (48.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.9V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.72 V 10 panels 557.2 V 17 panels
-10 C (14 F) 54.21 V 11 panels 596.3 V 18 panels
0 C (32 F) 52.69 V 11 panels 579.6 V 18 panels
25 C (77 F STC) 48.9 V 12 panels 586.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to TSEC TS72-AMH-440 H1?

Four comparable CEC modules such as ELITE Solar ET-M672BH440WW (440.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ELITE Solar ET-M672BH440WW
ELITE Solar
440.0 W Tie (0 W) 48.9 V 20.47% 93.5%
CSI Solar Co Ltd CS3W-440MS
CSI Solar Co Ltd
440.0 W Tie (0 W) 48.7 V 20.56% 93.1%
Apollo Renewables Inc Apollo-M672BH-440TW
Apollo Renewables Inc
440.0 W Tie (0 W) 49.2 V 20.47% 93.4%
Bluesun Solar CoLtd BSM440M-72HPH
Bluesun Solar CoLtd
440.0 W Tie (0 W) 49.2 V 20.28% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for TSEC TS72-AMH-440 H1?

Evaluate TSEC TS72-AMH-440 H1 (440.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), TSEC TS72-AMH-440 H1 reaches 55.72 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of TSEC TS72-AMH-440 H1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

TSEC TS72-AMH-440 H1 8 kW Residential Fit

Needs 19 modules (442 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-M672BH440WW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 408.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for TSEC TS72-AMH-440 H1 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is TSEC TS72-AMH-440 H1 PTC wattage (408.5 W) lower than STC (440.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 408.5 W PTC (92.8% retention) across TSEC TS72-AMH-440 H1's 2.16 m2 aperture.

Who should skip TSEC TS72-AMH-440 H1 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 TSEC TS72-AMH-440 H1 panels (442 sq ft) leave unusable roof gaps vs. ELITE Solar ET-M672BH440WW.

What is the 1,000 V commercial string limit for TSEC TS72-AMH-440 H1?

On 1,000 V commercial inverters at -10 C (54.21 V cold Voc), TSEC TS72-AMH-440 H1 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting TSEC TS72-AMH-440 H1.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.