TSEC TS60-AMH-380 H2 is a 380.0 W STC (352.1 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.99% efficiency, 41.3 V Voc at 25 C, and 45.64 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 352.1 W
- Voc @ 25C
- 41.3 V
- Efficiency
- 20.99%
How Does TSEC TS60-AMH-380 H2 Compare Against Peer CEC Listings?
Solar engineering breakdown for TSEC TS60-AMH-380 H2: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Measured at 380.0 W STC and 352.1 W PTC, TSEC TS60-AMH-380 H2 sits -5.0 W vs all-CEC median (below all-CEC median; higher than 47.6% of peers) among 21,677 listed modules. Power density reaches 209.9 W/m2 (1.08 percentage points above 19.91% CEC median). Mid-range 41.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 21 panels in series. Alternative peer DualSun SAS DualSun 380M-120-01 rates 380.0 W.
Where Does TSEC TS60-AMH-380 H2 Fall Across Listed CEC Models?
Distribution marker showing TSEC TS60-AMH-380 H2 (380.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define TSEC TS60-AMH-380 H2?
Dataset percentiles tracking TSEC TS60-AMH-380 H2 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for TSEC TS60-AMH-380 H2?
Benchmark highlights for TSEC TS60-AMH-380 H2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.99% Aperture Efficiency
Power density 209.9 W/m2 (1.08 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.64 V at -10 C (593.3 V string) and 46.88 V at -20 C (12 max).
22 Panels = 8,360 W STC
Occupies 39.8 m2 (429 sq ft) producing 7,746 W PTC; NEC 690.8 OCPD floor is 18.24 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.3 * (1 + (-0.3/100) * (-10 - 25)) = 45.64 V | OCPD = 1.56 * 11.69 = 18.24 A
Inputs from CEC Modules.csv for TSEC TS60-AMH-380 H2: Voc=41.3 V, beta_Voc=-0.3%/C, Isc=11.69 A, STC=380.0 W, Area=1.81 m2.
Result: 13 panels max on 600 V (593.3 V); 22 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for TSEC TS60-AMH-380 H2?
Official CEC datasheet figures for TSEC TS60-AMH-380 H2 (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 352.1 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.8 V / 10.92 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.3 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.99% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many TSEC TS60-AMH-380 H2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many TSEC TS60-AMH-380 H2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 312 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 429 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 526 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This TSEC Series?
Consolidated TSEC wattage variants sharing the TSEC TS60-AMH-380 H2 mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| TSEC TS60-AMH-375 H2 | 375.0 W | 347.3 W | 41.1 V | 34.6 V | 20.72% |
| TSEC TS60-AMH-380 H2 | 380.0 W | 352.1 W | 41.3 V | 34.8 V | 20.99% |
How Many TSEC TS60-AMH-380 H2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on TSEC TS60-AMH-380 H2 (45.64 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.88 V | 12 panels | 562.6 V | 21 panels |
| -10 C (14 F) | 45.64 V | 13 panels | 593.3 V | 21 panels |
| 0 C (32 F) | 44.4 V | 13 panels | 577.2 V | 22 panels |
| 25 C (77 F STC) | 41.3 V | 14 panels | 578.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to TSEC TS60-AMH-380 H2?
Competing CEC solar panels closest to TSEC TS60-AMH-380 H2 in nameplate wattage and Voc, starting with DualSun SAS DualSun 380M-120-01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 380M-120-01 DualSun SAS |
380.0 W | Tie (0 W) | 41.3 V | 21.47% | 93.9% |
| Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC Boviet Solar Technology Co Ltd |
380.0 W | Tie (0 W) | 40.94 V | 20.54% | 94.2% |
| CSI Solar Co Ltd CS3L-375P CSI Solar Co Ltd |
375.0 W | -5.0 W | 41.2 V | 20.95% | 92.5% |
| CSI Solar Co Ltd CS3L-385MS CSI Solar Co Ltd |
385.0 W | +5.0 W | 41.4 V | 21.51% | 93.2% |
What Are the Design Limits and Best-Fit Uses for TSEC TS60-AMH-380 H2?
Evaluate TSEC TS60-AMH-380 H2 (380.0 W STC, 41.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), TSEC TS60-AMH-380 H2 reaches 46.88 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
- 2026 tax credit baseline: cash residential installs of TSEC TS60-AMH-380 H2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
TSEC TS60-AMH-380 H2 8 kW Residential Fit
Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 380M-120-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 352.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for TSEC TS60-AMH-380 H2 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many TSEC TS60-AMH-380 H2 panels fit on a 600 V winter solar string?
At -10 C (14 F), TSEC TS60-AMH-380 H2 cold Voc rises from 41.3 V to 45.64 V (beta_Voc -0.3%/C), capping a 600 V string at 13 panels (593.3 V).
How much roof area does an 8 kW array of TSEC TS60-AMH-380 H2 need?
An 8 kW DC system uses 22 TSEC TS60-AMH-380 H2 modules (8,360 W STC / 7,746 W PTC), covering roughly 429 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does TSEC TS60-AMH-380 H2 compare against DualSun SAS DualSun 380M-120-01?
TSEC TS60-AMH-380 H2 outputs 380.0 W STC (41.3 V Voc, rank #11,043 of 21,677), while DualSun SAS DualSun 380M-120-01 delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)