TSEC TS60-AMH-380 H2 — CEC Solar Module Specifications

Manufacturer: TSEC Registry: CEC Verified Engineering Specification

TSEC TS60-AMH-380 H2 is a 380.0 W STC (352.1 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.99% efficiency, 41.3 V Voc at 25 C, and 45.64 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
352.1 W
Voc @ 25C
41.3 V
Efficiency
20.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does TSEC TS60-AMH-380 H2 Compare Against Peer CEC Listings?

Solar engineering breakdown for TSEC TS60-AMH-380 H2: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Measured at 380.0 W STC and 352.1 W PTC, TSEC TS60-AMH-380 H2 sits -5.0 W vs all-CEC median (below all-CEC median; higher than 47.6% of peers) among 21,677 listed modules. Power density reaches 209.9 W/m2 (1.08 percentage points above 19.91% CEC median). Mid-range 41.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 21 panels in series. Alternative peer DualSun SAS DualSun 380M-120-01 rates 380.0 W.

Where Does TSEC TS60-AMH-380 H2 Fall Across Listed CEC Models?

Distribution marker showing TSEC TS60-AMH-380 H2 (380.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where TSEC TS60-AMH-380 H2 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTSEC TS60-AMH-380 : 380.0 W

What Dataset Percentiles Define TSEC TS60-AMH-380 H2?

Dataset percentiles tracking TSEC TS60-AMH-380 H2 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

TSEC TS60-AMH-380 H2 Engineering BenchmarksPercentile comparison of TSEC TS60-AMH-380 H2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention92.7%Module Efficiency20.99%

What Do the Dataset Ranks Show for TSEC TS60-AMH-380 H2?

Benchmark highlights for TSEC TS60-AMH-380 H2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,482

20.99% Aperture Efficiency

Power density 209.9 W/m2 (1.08 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.64 V at -10 C (593.3 V string) and 46.88 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 39.8 m2 (429 sq ft) producing 7,746 W PTC; NEC 690.8 OCPD floor is 18.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.3 * (1 + (-0.3/100) * (-10 - 25)) = 45.64 V | OCPD = 1.56 * 11.69 = 18.24 A

Inputs from CEC Modules.csv for TSEC TS60-AMH-380 H2: Voc=41.3 V, beta_Voc=-0.3%/C, Isc=11.69 A, STC=380.0 W, Area=1.81 m2.

Result: 13 panels max on 600 V (593.3 V); 22 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for TSEC TS60-AMH-380 H2?

Official CEC datasheet figures for TSEC TS60-AMH-380 H2 (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for TSEC TS60-AMH-380 H2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 352.1 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.69 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.8 V / 10.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.99% (1.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many TSEC TS60-AMH-380 H2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many TSEC TS60-AMH-380 H2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 312 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 429 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 526 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This TSEC Series?

Consolidated TSEC wattage variants sharing the TSEC TS60-AMH-380 H2 mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the TSEC TS60-AMH-380 H2 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
TSEC TS60-AMH-375 H2 375.0 W 347.3 W 41.1 V 34.6 V 20.72%
TSEC TS60-AMH-380 H2 380.0 W 352.1 W 41.3 V 34.8 V 20.99%

How Many TSEC TS60-AMH-380 H2 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on TSEC TS60-AMH-380 H2 (45.64 V at 14 F).

Computed from Voc=41.3V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.88 V 12 panels 562.6 V 21 panels
-10 C (14 F) 45.64 V 13 panels 593.3 V 21 panels
0 C (32 F) 44.4 V 13 panels 577.2 V 22 panels
25 C (77 F STC) 41.3 V 14 panels 578.2 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to TSEC TS60-AMH-380 H2?

Competing CEC solar panels closest to TSEC TS60-AMH-380 H2 in nameplate wattage and Voc, starting with DualSun SAS DualSun 380M-120-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 380M-120-01
DualSun SAS
380.0 W Tie (0 W) 41.3 V 21.47% 93.9%
Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC
Boviet Solar Technology Co Ltd
380.0 W Tie (0 W) 40.94 V 20.54% 94.2%
CSI Solar Co Ltd CS3L-375P
CSI Solar Co Ltd
375.0 W -5.0 W 41.2 V 20.95% 92.5%
CSI Solar Co Ltd CS3L-385MS
CSI Solar Co Ltd
385.0 W +5.0 W 41.4 V 21.51% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for TSEC TS60-AMH-380 H2?

Evaluate TSEC TS60-AMH-380 H2 (380.0 W STC, 41.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), TSEC TS60-AMH-380 H2 reaches 46.88 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
  • 2026 tax credit baseline: cash residential installs of TSEC TS60-AMH-380 H2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

TSEC TS60-AMH-380 H2 8 kW Residential Fit

Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 380M-120-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 352.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for TSEC TS60-AMH-380 H2 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many TSEC TS60-AMH-380 H2 panels fit on a 600 V winter solar string?

At -10 C (14 F), TSEC TS60-AMH-380 H2 cold Voc rises from 41.3 V to 45.64 V (beta_Voc -0.3%/C), capping a 600 V string at 13 panels (593.3 V).

How much roof area does an 8 kW array of TSEC TS60-AMH-380 H2 need?

An 8 kW DC system uses 22 TSEC TS60-AMH-380 H2 modules (8,360 W STC / 7,746 W PTC), covering roughly 429 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does TSEC TS60-AMH-380 H2 compare against DualSun SAS DualSun 380M-120-01?

TSEC TS60-AMH-380 H2 outputs 380.0 W STC (41.3 V Voc, rank #11,043 of 21,677), while DualSun SAS DualSun 380M-120-01 delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?