TSEC TS54-BMH-395 H1 — CEC Solar Module Specifications

Manufacturer: TSEC Registry: CEC Verified Engineering Specification

TSEC TS54-BMH-395 H1 is a 395.0 W STC (365.9 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.36% efficiency, 36.9 V Voc at 25 C, and 40.65 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
365.9 W
Voc @ 25C
36.9 V
Efficiency
20.36%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does TSEC TS54-BMH-395 H1 Compare Against Peer CEC Listings?

Engineering position of TSEC TS54-BMH-395 H1 (395.0 W STC) vs. BYD Company Limited BYD395MLK-27 across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, TSEC TS54-BMH-395 H1 pairs strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677) with 36.9 V nominal Voc. An 8 kW residential build (8,295 W DC, 7,684 W PTC) saves ~$2,075/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer BYD Company Limited BYD395MLK-27 offers a 395.0 W alternative.

Where Does TSEC TS54-BMH-395 H1 Fall Across Listed CEC Models?

Plots TSEC TS54-BMH-395 H1 at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where TSEC TS54-BMH-395 H1 (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTSEC TS54-BMH-395 : 395.0 W

What Dataset Percentiles Define TSEC TS54-BMH-395 H1?

Benchmarks TSEC TS54-BMH-395 H1 on STC wattage, thermal PTC/STC retention, and 20.36 aperture conversion efficiency against CEC peers.

TSEC TS54-BMH-395 H1 Engineering BenchmarksPercentile comparison of TSEC TS54-BMH-395 H1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention92.6%Module Efficiency20.36%

What Do the Dataset Ranks Show for TSEC TS54-BMH-395 H1?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for TSEC TS54-BMH-395 H1 by TSEC.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,064

20.36% Aperture Efficiency

Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.65 V at -10 C (569.1 V string) and 41.72 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 40.7 m2 (439 sq ft) producing 7,684 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.9 * (1 + (-0.29/100) * (-10 - 25)) = 40.65 V | OCPD = 1.56 * 13.71 = 21.39 A

Inputs from CEC Modules.csv for TSEC TS54-BMH-395 H1: Voc=36.9 V, beta_Voc=-0.29%/C, Isc=13.71 A, STC=395.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (569.1 V); 21 panels for 8 kW (439 sq ft).

What Are the Published CEC Specifications for TSEC TS54-BMH-395 H1?

Laboratory test ratings recorded for TSEC TS54-BMH-395 H1 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for TSEC TS54-BMH-395 H1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 365.9 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.32 V / 13.03 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.29 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.36% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many TSEC TS54-BMH-395 H1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (439 sq ft at 8 kW), and estimated Year-1 electric bill offset for TSEC TS54-BMH-395 H1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 334 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 439 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 543 sq ft $2,570 $4,347

Which Sibling Wattage & Trim Variants Belong to This TSEC Series?

Sibling wattage bins and frame colors grouped with TSEC TS54-BMH-395 H1 under TSEC to prevent duplicate spec pages.

Sibling CEC listings grouped into the TSEC TS54-BMH-395 H1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
TSEC TS54-BMH-390 H1 390.0 W 361.1 W 36.82 V 30.22 V 20.1%
TSEC TS54-BMH-395 H1 395.0 W 365.9 W 36.9 V 30.32 V 20.36%

How Many TSEC TS54-BMH-395 H1 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for TSEC TS54-BMH-395 H1 (beta_Voc -0.29%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.9V and beta_Voc=-0.29%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.72 V 14 panels 584.1 V 23 panels
-10 C (14 F) 40.65 V 14 panels 569.1 V 24 panels
0 C (32 F) 39.58 V 15 panels 593.7 V 25 panels
25 C (77 F STC) 36.9 V 16 panels 590.4 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to TSEC TS54-BMH-395 H1?

Closest cross-brand CEC competitors to TSEC TS54-BMH-395 H1 matched near 395.0 W STC and 36.9 V Voc, led by BYD Company Limited BYD395MLK-27.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD395MLK-27
BYD Company Limited
395.0 W Tie (0 W) 36.9 V 20.36% 92.6%
Energate Energy Inc EG-108L395W
Energate Energy Inc
395.0 W Tie (0 W) 36.9 V 20.36% 93.6%
Energate Enerji retim San A EG-108L395W
Energate Enerji retim San A
395.0 W Tie (0 W) 36.9 V 20.36% 93.6%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
395.0 W Tie (0 W) 36.94 V 20.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for TSEC TS54-BMH-395 H1?

Evaluate TSEC TS54-BMH-395 H1 (395.0 W STC, 36.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), TSEC TS54-BMH-395 H1 reaches 41.72 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of TSEC TS54-BMH-395 H1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

TSEC TS54-BMH-395 H1 8 kW Residential Fit

Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD395MLK-27.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for TSEC TS54-BMH-395 H1 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for TSEC TS54-BMH-395 H1?

Multiplying TSEC TS54-BMH-395 H1's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can TSEC TS54-BMH-395 H1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.65 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap TSEC TS54-BMH-395 H1 at 14 panels on 600 V.

Is TSEC TS54-BMH-395 H1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of TSEC TS54-BMH-395 H1 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls