TSEC TS54-BMH-395 H1 is a 395.0 W STC (365.9 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.36% efficiency, 36.9 V Voc at 25 C, and 40.65 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 365.9 W
- Voc @ 25C
- 36.9 V
- Efficiency
- 20.36%
How Does TSEC TS54-BMH-395 H1 Compare Against Peer CEC Listings?
Engineering position of TSEC TS54-BMH-395 H1 (395.0 W STC) vs. BYD Company Limited BYD395MLK-27 across 5,889 CEC Mono-c-Si solar modules.
Built with 54 Mono-c-Si cells, TSEC TS54-BMH-395 H1 pairs strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677) with 36.9 V nominal Voc. An 8 kW residential build (8,295 W DC, 7,684 W PTC) saves ~$2,075/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer BYD Company Limited BYD395MLK-27 offers a 395.0 W alternative.
Where Does TSEC TS54-BMH-395 H1 Fall Across Listed CEC Models?
Plots TSEC TS54-BMH-395 H1 at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define TSEC TS54-BMH-395 H1?
Benchmarks TSEC TS54-BMH-395 H1 on STC wattage, thermal PTC/STC retention, and 20.36 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for TSEC TS54-BMH-395 H1?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for TSEC TS54-BMH-395 H1 by TSEC.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.36% Aperture Efficiency
Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.65 V at -10 C (569.1 V string) and 41.72 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.7 m2 (439 sq ft) producing 7,684 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.9 * (1 + (-0.29/100) * (-10 - 25)) = 40.65 V | OCPD = 1.56 * 13.71 = 21.39 A
Inputs from CEC Modules.csv for TSEC TS54-BMH-395 H1: Voc=36.9 V, beta_Voc=-0.29%/C, Isc=13.71 A, STC=395.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (569.1 V); 21 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for TSEC TS54-BMH-395 H1?
Laboratory test ratings recorded for TSEC TS54-BMH-395 H1 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 365.9 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.32 V / 13.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.29 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.36% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many TSEC TS54-BMH-395 H1 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (439 sq ft at 8 kW), and estimated Year-1 electric bill offset for TSEC TS54-BMH-395 H1.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 334 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 439 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 543 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This TSEC Series?
Sibling wattage bins and frame colors grouped with TSEC TS54-BMH-395 H1 under TSEC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| TSEC TS54-BMH-390 H1 | 390.0 W | 361.1 W | 36.82 V | 30.22 V | 20.1% |
| TSEC TS54-BMH-395 H1 | 395.0 W | 365.9 W | 36.9 V | 30.32 V | 20.36% |
How Many TSEC TS54-BMH-395 H1 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for TSEC TS54-BMH-395 H1 (beta_Voc -0.29%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.72 V | 14 panels | 584.1 V | 23 panels |
| -10 C (14 F) | 40.65 V | 14 panels | 569.1 V | 24 panels |
| 0 C (32 F) | 39.58 V | 15 panels | 593.7 V | 25 panels |
| 25 C (77 F STC) | 36.9 V | 16 panels | 590.4 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to TSEC TS54-BMH-395 H1?
Closest cross-brand CEC competitors to TSEC TS54-BMH-395 H1 matched near 395.0 W STC and 36.9 V Voc, led by BYD Company Limited BYD395MLK-27.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD395MLK-27 BYD Company Limited |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.6% |
| Energate Energy Inc EG-108L395W Energate Energy Inc |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 93.6% |
| Energate Enerji retim San A EG-108L395W Energate Enerji retim San A |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 93.6% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
395.0 W | Tie (0 W) | 36.94 V | 20.47% | 92.6% |
What Are the Design Limits and Best-Fit Uses for TSEC TS54-BMH-395 H1?
Evaluate TSEC TS54-BMH-395 H1 (395.0 W STC, 36.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), TSEC TS54-BMH-395 H1 reaches 41.72 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of TSEC TS54-BMH-395 H1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
TSEC TS54-BMH-395 H1 8 kW Residential Fit
Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD395MLK-27.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for TSEC TS54-BMH-395 H1 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for TSEC TS54-BMH-395 H1?
Multiplying TSEC TS54-BMH-395 H1's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can TSEC TS54-BMH-395 H1 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.65 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap TSEC TS54-BMH-395 H1 at 14 panels on 600 V.
Is TSEC TS54-BMH-395 H1 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of TSEC TS54-BMH-395 H1 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)