Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-550DEG19C20 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-550DEG19C20 is a 550.0 W STC (517.9 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.24% efficiency, 38.1 V Voc at 25 C, and 41.33 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
550.0 W
PTC Wattage
517.9 W
Voc @ 25C
38.1 V
Efficiency
21.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-550DEG19C20 Compare Against Peer CEC Listings?

Solar engineering breakdown for Trina Solar TSM-550DEG19C20: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Measured at 550.0 W STC and 517.9 W PTC, Trina Solar TSM-550DEG19C20 sits +165.0 W vs all-CEC median (top 13.8%; higher than 86.2% of peers) among 21,677 listed modules. Power density reaches 212.4 W/m2 (1.33 percentage points above 19.91% CEC median). Lower 38.1 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12 rates 550.0 W.

Where Does Trina Solar TSM-550DEG19C20 Fall Across Listed CEC Models?

Distribution marker showing Trina Solar TSM-550DEG19C20 (550.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-550DEG19C20 (550.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-55: 550.0 W

What Dataset Percentiles Define Trina Solar TSM-550DEG19C20?

Dataset percentiles tracking Trina Solar TSM-550DEG19C20 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Trina Solar TSM-550DEG19C20 Engineering BenchmarksPercentile comparison of Trina Solar TSM-550DEG19C20 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage550.0 WPTC/STC Retention94.2%Module Efficiency21.24%

What Do the Dataset Ranks Show for Trina Solar TSM-550DEG19C20?

Benchmark highlights for Trina Solar TSM-550DEG19C20 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #2,737 / 21,677

Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,440

21.24% Aperture Efficiency

Power density 212.4 W/m2 (1.33 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.33 V at -10 C (578.6 V string) and 42.25 V at -20 C (14 max).

8 kW Reference Array

15 Panels = 8,250 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,768 W PTC; NEC 690.8 OCPD floor is 28.69 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.1 * (1 + (-0.242/100) * (-10 - 25)) = 41.33 V | OCPD = 1.56 * 18.39 = 28.69 A

Inputs from CEC Modules.csv for Trina Solar TSM-550DEG19C20: Voc=38.1 V, beta_Voc=-0.242%/C, Isc=18.39 A, STC=550.0 W, Area=2.59 m2.

Result: 14 panels max on 600 V (578.6 V); 15 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-550DEG19C20?

Official CEC datasheet figures for Trina Solar TSM-550DEG19C20 (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-550DEG19C20.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 550.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 517.9 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.39 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.8 V / 17.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.242 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.24% (2.59 m2) Array roof footprint density
Cell Count & Technology 55 cells (Mono-c-Si) Bifacial glass-glass

How Many Trina Solar TSM-550DEG19C20 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Trina Solar TSM-550DEG19C20 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.05 kW 307 sq ft $1,514 $2,561
8 kW Class 15 8.25 kW 418 sq ft $2,065 $3,492
10 kW Class 19 10.45 kW 530 sq ft $2,616 $4,423

How Many Trina Solar TSM-550DEG19C20 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-550DEG19C20 (41.33 V at 14 F).

Computed from Voc=38.1V and beta_Voc=-0.242%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.25 V 14 panels 591.5 V 23 panels
-10 C (14 F) 41.33 V 14 panels 578.6 V 24 panels
0 C (32 F) 40.41 V 14 panels 565.7 V 24 panels
25 C (77 F STC) 38.1 V 15 panels 571.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-550DEG19C20?

Competing CEC solar panels closest to Trina Solar TSM-550DEG19C20 in nameplate wattage and Voc, starting with CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET
550.0 W Tie (0 W) 37.9 V 21.48% 93.7%
CSI Solar Co Ltd CS7L-570MB-AG
CSI Solar Co Ltd
570.0 W +20.0 W 40.1 V 26.64% 93.8%
AMPS Solar AMPS-550P-144SW
AMPS Solar
550.0 W Tie (0 W) 49.05 V 21.48% 94.3%
CSI Solar Co Ltd CS7L-585MB-AG
CSI Solar Co Ltd
585.0 W +35.0 W 40.7 V 27.34% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-550DEG19C20?

Evaluate Trina Solar TSM-550DEG19C20 (550.0 W STC, 38.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-550DEG19C20 reaches 42.25 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 418 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-550DEG19C20 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-550DEG19C20 8 kW Residential Fit

Needs 15 modules (418 sq ft) with a 30 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 517.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-550DEG19C20 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-550DEG19C20 panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-550DEG19C20 cold Voc rises from 38.1 V to 41.33 V (beta_Voc -0.242%/C), capping a 600 V string at 14 panels (578.6 V).

How much roof area does an 8 kW array of Trina Solar TSM-550DEG19C20 need?

An 8 kW DC system uses 15 Trina Solar TSM-550DEG19C20 modules (8,250 W STC / 7,768 W PTC), covering roughly 418 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does Trina Solar TSM-550DEG19C20 compare against CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12?

Trina Solar TSM-550DEG19C20 outputs 550.0 W STC (38.1 V Voc, rank #2,737 of 21,677), while CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12 delivers 550.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.