Trina Solar TSM-420NEG9RH25 is a 420.0 W STC (396.6 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.21% efficiency, 34.7 V Voc at 25 C, and 37.78 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 396.6 W
- Voc @ 25C
- 34.7 V
- Efficiency
- 21.21%
How Does Trina Solar TSM-420NEG9RH25 Compare Against Peer CEC Listings?
Engineering position of Trina Solar TSM-420NEG9RH25 (420.0 W STC) vs. Auxin Solar AXN10M420W across 5,889 CEC Mono-c-Si solar modules.
Built with 16 Mono-c-Si cells, Trina Solar TSM-420NEG9RH25 pairs strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677) with 34.7 V nominal Voc. An 8 kW residential build (8,400 W DC, 7,932 W PTC) saves ~$2,102/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Auxin Solar AXN10M420W offers a 420.0 W alternative.
Where Does Trina Solar TSM-420NEG9RH25 Fall Across Listed CEC Models?
Plots Trina Solar TSM-420NEG9RH25 at 420.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Trina Solar TSM-420NEG9RH25?
Benchmarks Trina Solar TSM-420NEG9RH25 on STC wattage, thermal PTC/STC retention, and 21.21 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Trina Solar TSM-420NEG9RH25?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-420NEG9RH25 by Trina Solar.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.21% Aperture Efficiency
Power density 212.1 W/m2 (1.30 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 37.78 V at -10 C (566.7 V string) and 38.67 V at -20 C (15 max).
20 Panels = 8,400 W STC
Occupies 39.6 m2 (426 sq ft) producing 7,932 W PTC; NEC 690.8 OCPD floor is 24.4 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 34.7 * (1 + (-0.254/100) * (-10 - 25)) = 37.78 V | OCPD = 1.56 * 15.64 = 24.4 A
Inputs from CEC Modules.csv for Trina Solar TSM-420NEG9RH25: Voc=34.7 V, beta_Voc=-0.254%/C, Isc=15.64 A, STC=420.0 W, Area=1.98 m2.
Result: 15 panels max on 600 V (566.7 V); 20 panels for 8 kW (426 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-420NEG9RH25?
Laboratory test ratings recorded for Trina Solar TSM-420NEG9RH25 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 396.6 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 34.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 28.4 V / 14.79 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.254 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.21% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 16 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-420NEG9RH25 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (426 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-420NEG9RH25.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 320 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 426 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 512 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Sibling wattage bins and frame colors grouped with Trina Solar TSM-420NEG9RH25 under Trina Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-415NEG9RH25 | 415.0 W | 391.8 W | 34.5 V | 28.1 V | 20.96% |
| Trina Solar TSM-420NEG9RH25 | 420.0 W | 396.6 W | 34.7 V | 28.4 V | 21.21% |
How Many Trina Solar TSM-420NEG9RH25 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Trina Solar TSM-420NEG9RH25 (beta_Voc -0.254%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 38.67 V | 15 panels | 580.1 V | 25 panels |
| -10 C (14 F) | 37.78 V | 15 panels | 566.7 V | 26 panels |
| 0 C (32 F) | 36.9 V | 16 panels | 590.4 V | 27 panels |
| 25 C (77 F STC) | 34.7 V | 17 panels | 589.9 V | 28 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-420NEG9RH25?
Closest cross-brand CEC competitors to Trina Solar TSM-420NEG9RH25 matched near 420.0 W STC and 34.7 V Voc, led by Auxin Solar AXN10M420W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M420W Auxin Solar |
420.0 W | Tie (0 W) | 38.26 V | 21.65% | 93.2% |
| Aptos Solar Technology LLC DNA-108-MFN10-420W Aptos Solar Technology LLC |
420.0 W | Tie (0 W) | 38.5 V | 21.65% | 95.0% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420 Elin Energy (Sirius PV) |
420.0 W | Tie (0 W) | 38.5 V | 21.65% | 94.9% |
| Elin Energy (Sirius PV) ELNSM54M-HC-N-420 Elin Energy (Sirius PV) |
420.0 W | Tie (0 W) | 38.5 V | 21.65% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-420NEG9RH25?
Evaluate Trina Solar TSM-420NEG9RH25 (420.0 W STC, 34.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-420NEG9RH25 reaches 38.67 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-420NEG9RH25 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-420NEG9RH25 8 kW Residential Fit
Needs 20 modules (426 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Auxin Solar AXN10M420W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 396.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-420NEG9RH25 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-420NEG9RH25?
Multiplying Trina Solar TSM-420NEG9RH25's 15.64 A short-circuit current by 1.56 equals 24.4 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Trina Solar TSM-420NEG9RH25 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 37.78 V cold Voc at 14 F and handles 15.64 A Isc; string inverters cap Trina Solar TSM-420NEG9RH25 at 15 panels on 600 V.
Is Trina Solar TSM-420NEG9RH25 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-420NEG9RH25 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)