Trina Solar TSM-410NE09RC05 is a 410.0 W STC (385.7 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.71% efficiency, 50.1 V Voc at 25 C, and 54.52 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 385.7 W
- Voc @ 25C
- 50.1 V
- Efficiency
- 20.71%
How Does Trina Solar TSM-410NE09RC05 Compare Against Peer CEC Listings?
How Trina Solar Trina Solar TSM-410NE09RC05 handles rooftop heat (385.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Trina Solar TSM-410NE09RC05 exhibits 10.37 A short-circuit current, requiring a 16.18 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #8,539 of 21,677 (equal to the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.6 m2 for an 8 kW system (25 panels for 10 kW). Higher 50.1 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Trina Solar TSM-410NE09RC05 Fall Across Listed CEC Models?
Where Trina Solar TSM-410NE09RC05 (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Trina Solar TSM-410NE09RC05?
Percentile placement of Trina Solar TSM-410NE09RC05 across power density (207.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Trina Solar TSM-410NE09RC05?
Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-410NE09RC05 specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.71% Aperture Efficiency
Power density 207.1 W/m2 (0.80 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.52 V at -10 C (599.7 V string) and 55.78 V at -20 C (10 max).
20 Panels = 8,200 W STC
Occupies 39.6 m2 (426 sq ft) producing 7,714 W PTC; NEC 690.8 OCPD floor is 16.18 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.1 * (1 + (-0.252/100) * (-10 - 25)) = 54.52 V | OCPD = 1.56 * 10.37 = 16.18 A
Inputs from CEC Modules.csv for Trina Solar TSM-410NE09RC05: Voc=50.1 V, beta_Voc=-0.252%/C, Isc=10.37 A, STC=410.0 W, Area=1.98 m2.
Result: 11 panels max on 600 V (599.7 V); 20 panels for 8 kW (426 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-410NE09RC05?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-410NE09RC05.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 385.7 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.1 V / 9.73 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.252 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.71% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-410NE09RC05 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-410NE09RC05 (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 320 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 426 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 533 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-410NE09RC05 architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-400NE09RC05 | 400.0 W | 376.1 W | 49.2 V | 41.3 V | 20.2% |
| Trina Solar TSM-405NE09RC05 | 405.0 W | 380.9 W | 49.6 V | 41.7 V | 20.45% |
| Trina Solar TSM-410NE09RC05 | 410.0 W | 385.7 W | 50.1 V | 42.1 V | 20.71% |
| Trina Solar TSM-415NE09RC05 | 415.0 W | 390.5 W | 50.5 V | 42.5 V | 20.96% |
| Trina Solar TSM-420NE09RC05 | 420.0 W | 395.4 W | 50.9 V | 42.8 V | 21.21% |
How Many Trina Solar TSM-410NE09RC05 Modules Fit in a Cold-Weather String?
Maximum series module counts for Trina Solar TSM-410NE09RC05 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.78 V | 10 panels | 557.8 V | 17 panels |
| -10 C (14 F) | 54.52 V | 11 panels | 599.7 V | 18 panels |
| 0 C (32 F) | 53.26 V | 11 panels | 585.9 V | 18 panels |
| 25 C (77 F STC) | 50.1 V | 11 panels | 551.1 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-410NE09RC05?
Alternative CEC solar modules from competing brands near Trina Solar TSM-410NE09RC05 (410.0 W), including Auxin Solar AXNG1M410B. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
| AXITEC AC-410MB/144V AXITEC |
410.0 W | Tie (0 W) | 49.3 V | 21.03% | 93.0% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-410NE09RC05?
Evaluate Trina Solar TSM-410NE09RC05 (410.0 W STC, 50.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-410NE09RC05 reaches 55.78 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-410NE09RC05 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-410NE09RC05 8 kW Residential Fit
Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXNG1M410B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 385.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-410NE09RC05 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Trina Solar TSM-410NE09RC05 PTC wattage (385.7 W) lower than STC (410.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 385.7 W PTC (94.1% retention) across Trina Solar TSM-410NE09RC05's 1.98 m2 aperture.
Who should skip Trina Solar TSM-410NE09RC05 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Trina Solar TSM-410NE09RC05 panels (426 sq ft) leave unusable roof gaps vs. Auxin Solar AXNG1M410B.
What is the 1,000 V commercial string limit for Trina Solar TSM-410NE09RC05?
On 1,000 V commercial inverters at -10 C (54.52 V cold Voc), Trina Solar TSM-410NE09RC05 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-410NE09RC05.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)