Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-380DEG14HC27(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-380DEG14HC27(II) is a 380.0 W STC (354.8 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.19% efficiency, 49.2 V Voc at 25 C, and 54.14 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
354.8 W
Voc @ 25C
49.2 V
Efficiency
19.19%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-380DEG14HC27(II) Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-380DEG14HC27(II) handles rooftop heat (354.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Trina Solar TSM-380DEG14HC27(II) exhibits 9.99 A short-circuit current, requiring a 15.58 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,043 of 21,677 (30.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 43.6 m2 for an 8 kW system (27 panels for 10 kW). Higher 49.2 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Trina Solar TSM-380DEG14HC27(II) Fall Across Listed CEC Models?

Where Trina Solar TSM-380DEG14HC27(II) (380.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-380DEG14HC27(II) (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-38: 380.0 W

What Dataset Percentiles Define Trina Solar TSM-380DEG14HC27(II)?

Percentile placement of Trina Solar TSM-380DEG14HC27(II) across power density (191.9 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-380DEG14HC27(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-380DEG14HC27(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention93.4%Module Efficiency19.19%

What Do the Dataset Ranks Show for Trina Solar TSM-380DEG14HC27(II)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-380DEG14HC27(II) specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,008

19.19% Aperture Efficiency

Power density 191.9 W/m2 (0.72 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.14 V at -10 C (595.5 V string) and 55.55 V at -20 C (10 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 43.6 m2 (469 sq ft) producing 7,806 W PTC; NEC 690.8 OCPD floor is 15.58 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.2 * (1 + (-0.287/100) * (-10 - 25)) = 54.14 V | OCPD = 1.56 * 9.99 = 15.58 A

Inputs from CEC Modules.csv for Trina Solar TSM-380DEG14HC27(II): Voc=49.2 V, beta_Voc=-0.287%/C, Isc=9.99 A, STC=380.0 W, Area=1.98 m2.

Result: 11 panels max on 600 V (595.5 V); 22 panels for 8 kW (469 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-380DEG14HC27(II)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-380DEG14HC27(II).

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-380DEG14HC27(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 354.8 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.99 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.3 V / 9.43 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.287 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.19% (1.98 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Bifacial glass-glass

How Many Trina Solar TSM-380DEG14HC27(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-380DEG14HC27(II) (380.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 341 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 469 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 575 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-380DEG14HC27(II) architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Trina Solar TSM-380DEG14HC27(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-375DEG14HC27(II) 375.0 W 350.1 W 49.0 V 40.2 V 18.94%
Trina Solar TSM-380DEG14HC27(II) 380.0 W 354.8 W 49.2 V 40.3 V 19.19%

How Many Trina Solar TSM-380DEG14HC27(II) Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-380DEG14HC27(II) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.2V and beta_Voc=-0.287%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.55 V 10 panels 555.5 V 18 panels
-10 C (14 F) 54.14 V 11 panels 595.5 V 18 panels
0 C (32 F) 52.73 V 11 panels 580.0 V 18 panels
25 C (77 F STC) 49.2 V 12 panels 590.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-380DEG14HC27(II)?

Alternative CEC solar modules from competing brands near Trina Solar TSM-380DEG14HC27(II) (380.0 W), including Auxin Solar AXN6M612B380.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612B380
Auxin Solar
380.0 W Tie (0 W) 47.94 V 19.3% 93.1%
CSI Solar Co Ltd CS3U-380PB-AG
CSI Solar Co Ltd
380.0 W Tie (0 W) 47.8 V 19.29% 93.5%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.15% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.06% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-380DEG14HC27(II)?

Evaluate Trina Solar TSM-380DEG14HC27(II) (380.0 W STC, 49.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-380DEG14HC27(II) reaches 55.55 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 469 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (469 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-380DEG14HC27(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-380DEG14HC27(II) 8 kW Residential Fit

Needs 22 modules (469 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXN6M612B380.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 354.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-380DEG14HC27(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-380DEG14HC27(II) PTC wattage (354.8 W) lower than STC (380.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 354.8 W PTC (93.4% retention) across Trina Solar TSM-380DEG14HC27(II)'s 1.98 m2 aperture.

Who should skip Trina Solar TSM-380DEG14HC27(II) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Trina Solar TSM-380DEG14HC27(II) panels (469 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M612B380.

What is the 1,000 V commercial string limit for Trina Solar TSM-380DEG14HC27(II)?

On 1,000 V commercial inverters at -10 C (54.14 V cold Voc), Trina Solar TSM-380DEG14HC27(II) fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-380DEG14HC27(II).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.