Trina Solar TSM-360DEG14C27(II) is a 360.0 W STC (334.8 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.37% efficiency, 48.0 V Voc at 25 C, and 52.7 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
334.8 W
Voc @ 25C
48.0 V
Efficiency
18.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-360DEG14C27(II) Compare Against Peer CEC Listings?

Solar engineering breakdown for Trina Solar TSM-360DEG14C27(II): PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 360.0 W STC and 334.8 W PTC, Trina Solar TSM-360DEG14C27(II) sits -25.0 W vs all-CEC median (below all-CEC median; higher than 41.3% of peers) among 21,677 listed modules. Power density reaches 183.7 W/m2 (1.54 percentage points below 19.91% CEC median). Higher 48.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Auxin Solar AXN6M612B360 rates 360.0 W.

Where Does Trina Solar TSM-360DEG14C27(II) Fall Across Listed CEC Models?

Distribution marker showing Trina Solar TSM-360DEG14C27(II) (360.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-360DEG14C27(II) (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-36: 360.0 W

What Dataset Percentiles Define Trina Solar TSM-360DEG14C27(II)?

Dataset percentiles tracking Trina Solar TSM-360DEG14C27(II) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Trina Solar TSM-360DEG14C27(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-360DEG14C27(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention93.0%Module Efficiency18.37%

What Do the Dataset Ranks Show for Trina Solar TSM-360DEG14C27(II)?

Benchmark highlights for Trina Solar TSM-360DEG14C27(II) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,557

18.37% Aperture Efficiency

Power density 183.7 W/m2 (1.54 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.7 V at -10 C (579.7 V string) and 54.05 V at -20 C (11 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 45.1 m2 (485 sq ft) producing 7,700 W PTC; NEC 690.8 OCPD floor is 15.1 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.0 * (1 + (-0.28/100) * (-10 - 25)) = 52.7 V | OCPD = 1.56 * 9.68 = 15.1 A

Inputs from CEC Modules.csv for Trina Solar TSM-360DEG14C27(II): Voc=48.0 V, beta_Voc=-0.28%/C, Isc=9.68 A, STC=360.0 W, Area=1.96 m2.

Result: 11 panels max on 600 V (579.7 V); 23 panels for 8 kW (485 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-360DEG14C27(II)?

Official CEC datasheet figures for Trina Solar TSM-360DEG14C27(II) (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-360DEG14C27(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 334.8 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.68 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.6 V / 9.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.28 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.37% (1.96 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Trina Solar TSM-360DEG14C27(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Trina Solar TSM-360DEG14C27(II) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 359 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 485 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 591 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-360DEG14C27(II) mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Trina Solar TSM-360DEG14C27(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-350DEG14C27(II) 350.0 W 325.3 W 47.6 V 39.2 V 17.86%
Trina Solar TSM-355DEG14C27(II) 355.0 W 330.0 W 47.8 V 39.4 V 18.11%
Trina Solar TSM-360DEG14C27(II) 360.0 W 334.8 W 48.0 V 39.6 V 18.37%
Trina Solar TSM-365DEG14C27(II) 365.0 W 339.6 W 48.2 V 39.8 V 18.62%

How Many Trina Solar TSM-360DEG14C27(II) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-360DEG14C27(II) (52.7 V at 14 F).

Computed from Voc=48.0V and beta_Voc=-0.28%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.05 V 11 panels 594.5 V 18 panels
-10 C (14 F) 52.7 V 11 panels 579.7 V 18 panels
0 C (32 F) 51.36 V 11 panels 565.0 V 19 panels
25 C (77 F STC) 48.0 V 12 panels 576.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-360DEG14C27(II)?

Competing CEC solar panels closest to Trina Solar TSM-360DEG14C27(II) in nameplate wattage and Voc, starting with Auxin Solar AXN6M612B360.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612B360
Auxin Solar
360.0 W Tie (0 W) 47.56 V 18.28% 93.0%
CSI Solar Co Ltd CS3U-360MB-AG
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.56% 93.8%
CSI Solar Co Ltd CS3U-360PB-AG
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.56% 92.5%
Auxin Solar AXN6M612B380
Auxin Solar
380.0 W +20.0 W 47.94 V 19.3% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-360DEG14C27(II)?

Evaluate Trina Solar TSM-360DEG14C27(II) (360.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-360DEG14C27(II) reaches 54.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 485 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (485 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-360DEG14C27(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-360DEG14C27(II) 8 kW Residential Fit

Needs 23 modules (485 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612B360.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 334.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-360DEG14C27(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-360DEG14C27(II) panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-360DEG14C27(II) cold Voc rises from 48.0 V to 52.7 V (beta_Voc -0.28%/C), capping a 600 V string at 11 panels (579.7 V).

How much roof area does an 8 kW array of Trina Solar TSM-360DEG14C27(II) need?

An 8 kW DC system uses 23 Trina Solar TSM-360DEG14C27(II) modules (8,280 W STC / 7,700 W PTC), covering roughly 485 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does Trina Solar TSM-360DEG14C27(II) compare against Auxin Solar AXN6M612B360?

Trina Solar TSM-360DEG14C27(II) outputs 360.0 W STC (48.0 V Voc, rank #12,385 of 21,677), while Auxin Solar AXN6M612B360 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.