Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-360DE14A(II) is a 360.0 W STC (324.9 W PTC) Multi-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.55% efficiency, 47.2 V Voc at 25 C, and 52.93 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
324.9 W
Voc @ 25C
47.2 V
Efficiency
18.55%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-360DE14A(II) Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-360DE14A(II) handles rooftop heat (324.9 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-360DE14A(II) (Multi-c-Si) as a compact residential or specialty off-grid module delivering 185.6 W/m2 (1.36 percentage points below 19.91% CEC median). Compared against CertainTeed CT360M11-03 (360.0 W), this model holds typical 90.2% PTC-to-STC thermal output (324.9 W real-world rating). Mid-range 47.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.27 A overcurrent floor served by a 20 A breaker.

Where Does Trina Solar TSM-360DE14A(II) Fall Across Listed CEC Models?

Where Trina Solar TSM-360DE14A(II) (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-360DE14A(II) (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-36: 360.0 W

What Dataset Percentiles Define Trina Solar TSM-360DE14A(II)?

Percentile placement of Trina Solar TSM-360DE14A(II) across power density (185.6 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-360DE14A(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-360DE14A(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention90.2%Module Efficiency18.55%

What Do the Dataset Ranks Show for Trina Solar TSM-360DE14A(II)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-360DE14A(II) specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #14,270

18.55% Aperture Efficiency

Power density 185.6 W/m2 (1.36 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.93 V at -10 C (582.2 V string) and 54.57 V at -20 C (10 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 44.6 m2 (480 sq ft) producing 7,473 W PTC; NEC 690.8 OCPD floor is 15.27 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.2 * (1 + (-0.347/100) * (-10 - 25)) = 52.93 V | OCPD = 1.56 * 9.79 = 15.27 A

Inputs from CEC Modules.csv for Trina Solar TSM-360DE14A(II): Voc=47.2 V, beta_Voc=-0.347%/C, Isc=9.79 A, STC=360.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (582.2 V); 23 panels for 8 kW (480 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-360DE14A(II)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-360DE14A(II).

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-360DE14A(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 324.9 W (90.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.79 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.9 V / 9.26 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.347 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.55% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-360DE14A(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-360DE14A(II) (360.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 355 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 480 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 585 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-360DE14A(II) architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Trina Solar TSM-360DE14A(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-350DE14A(II) 350.0 W 315.5 W 46.9 V 38.5 V 18.04%
Trina Solar TSM-355DE14A(II) 355.0 W 320.2 W 47.0 V 38.7 V 18.3%
Trina Solar TSM-360DE14A(II) 360.0 W 324.9 W 47.2 V 38.9 V 18.55%
Trina Solar TSM-365DE14A(II) 365.0 W 339.3 W 48.0 V 39.3 V 19.01%
Trina Solar TSM-370DE14A(II) 370.0 W 344.0 W 48.3 V 39.7 V 19.27%

How Many Trina Solar TSM-360DE14A(II) Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-360DE14A(II) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.2V and beta_Voc=-0.347%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.57 V 10 panels 545.7 V 18 panels
-10 C (14 F) 52.93 V 11 panels 582.2 V 18 panels
0 C (32 F) 51.29 V 11 panels 564.2 V 19 panels
25 C (77 F STC) 47.2 V 12 panels 566.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-360DE14A(II)?

Alternative CEC solar modules from competing brands near Trina Solar TSM-360DE14A(II) (360.0 W), including CertainTeed CT360M11-03. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CT360M11-03
CertainTeed
360.0 W Tie (0 W) 47.4 V 18.72% 92.3%
CSI Solar Co Ltd CS3U-360MS
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.76% 93.0%
CSI Solar Co Ltd CS3U-360MS-AG
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.75% 92.2%
CSI Solar Co Ltd CS3U-360P
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.75% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-360DE14A(II)?

Evaluate Trina Solar TSM-360DE14A(II) (360.0 W STC, 47.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-360DE14A(II) reaches 54.57 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 480 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (480 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-360DE14A(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-360DE14A(II) 8 kW Residential Fit

Needs 23 modules (480 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CertainTeed CT360M11-03.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 324.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-360DE14A(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-360DE14A(II)?

Multiplying Trina Solar TSM-360DE14A(II)'s 9.79 A short-circuit current by 1.56 equals 15.27 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Trina Solar TSM-360DE14A(II) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.93 V cold Voc at 14 F and handles 9.79 A Isc; string inverters cap Trina Solar TSM-360DE14A(II) at 11 panels on 600 V.

Is Trina Solar TSM-360DE14A(II) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-360DE14A(II) rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.