CSI Solar Co Ltd CS3U-360MS-AG is a 360.0 W STC (331.8 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.75% efficiency, 47.0 V Voc at 25 C, and 51.82 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 331.8 W
- Voc @ 25C
- 47.0 V
- Efficiency
- 18.75%
How Does CSI Solar Co Ltd CS3U-360MS-AG Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS3U-360MS-AG: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 360.0 W STC and 331.8 W PTC, CSI Solar Co Ltd CS3U-360MS-AG sits -25.0 W vs all-CEC median (below all-CEC median; higher than 41.3% of peers) among 21,677 listed modules. Power density reaches 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). Mid-range 47.0 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer CertainTeed CT360M11-03 rates 360.0 W.
Where Does CSI Solar Co Ltd CS3U-360MS-AG Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS3U-360MS-AG (360.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS3U-360MS-AG?
Dataset percentiles tracking CSI Solar Co Ltd CS3U-360MS-AG power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3U-360MS-AG?
Benchmark highlights for CSI Solar Co Ltd CS3U-360MS-AG covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.75% Aperture Efficiency
Power density 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.82 V at -10 C (570.0 V string) and 53.2 V at -20 C (11 max).
23 Panels = 8,280 W STC
Occupies 44.2 m2 (475 sq ft) producing 7,631 W PTC; NEC 690.8 OCPD floor is 15.12 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.0 * (1 + (-0.293/100) * (-10 - 25)) = 51.82 V | OCPD = 1.56 * 9.69 = 15.12 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3U-360MS-AG: Voc=47.0 V, beta_Voc=-0.293%/C, Isc=9.69 A, STC=360.0 W, Area=1.92 m2.
Result: 11 panels max on 600 V (570.0 V); 23 panels for 8 kW (475 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3U-360MS-AG?
Official CEC datasheet figures for CSI Solar Co Ltd CS3U-360MS-AG (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 331.8 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.2 V / 9.19 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.293 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.75% (1.92 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3U-360MS-AG Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS3U-360MS-AG modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 351 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 475 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 579 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS3U-360MS-AG mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-350MS-AG | 350.0 W | 322.3 W | 46.6 V | 38.8 V | 18.23% |
| CSI Solar Co Ltd CS3U-355MS-AG | 355.0 W | 327.1 W | 46.8 V | 39.0 V | 18.49% |
| CSI Solar Co Ltd CS3U-360MS-AG | 360.0 W | 331.8 W | 47.0 V | 39.2 V | 18.75% |
| CSI Solar Co Ltd CS3U-365MS-AG | 365.0 W | 336.5 W | 47.2 V | 39.4 V | 19.01% |
| CSI Solar Co Ltd CS3U-370MS-AG | 370.0 W | 341.3 W | 47.4 V | 39.6 V | 19.27% |
How Many CSI Solar Co Ltd CS3U-360MS-AG Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS3U-360MS-AG (51.82 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.2 V | 11 panels | 585.2 V | 18 panels |
| -10 C (14 F) | 51.82 V | 11 panels | 570.0 V | 19 panels |
| 0 C (32 F) | 50.44 V | 11 panels | 554.8 V | 19 panels |
| 25 C (77 F STC) | 47.0 V | 12 panels | 564.0 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3U-360MS-AG?
Competing CEC solar panels closest to CSI Solar Co Ltd CS3U-360MS-AG in nameplate wattage and Voc, starting with CertainTeed CT360M11-03.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT360M11-03 CertainTeed |
360.0 W | Tie (0 W) | 47.4 V | 18.72% | 92.3% |
| AXITEC AC-360M/72S AXITEC |
360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| AXITEC AC-360M/72V AXITEC |
360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3U-360MS-AG?
Evaluate CSI Solar Co Ltd CS3U-360MS-AG (360.0 W STC, 47.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3U-360MS-AG reaches 53.2 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 475 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (475 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3U-360MS-AG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3U-360MS-AG 8 kW Residential Fit
Needs 23 modules (475 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT360M11-03.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 331.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3U-360MS-AG by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many CSI Solar Co Ltd CS3U-360MS-AG panels fit on a 600 V winter solar string?
At -10 C (14 F), CSI Solar Co Ltd CS3U-360MS-AG cold Voc rises from 47.0 V to 51.82 V (beta_Voc -0.293%/C), capping a 600 V string at 11 panels (570.0 V).
How much roof area does an 8 kW array of CSI Solar Co Ltd CS3U-360MS-AG need?
An 8 kW DC system uses 23 CSI Solar Co Ltd CS3U-360MS-AG modules (8,280 W STC / 7,631 W PTC), covering roughly 475 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does CSI Solar Co Ltd CS3U-360MS-AG compare against CertainTeed CT360M11-03?
CSI Solar Co Ltd CS3U-360MS-AG outputs 360.0 W STC (47.0 V Voc, rank #12,385 of 21,677), while CertainTeed CT360M11-03 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)