Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-340DE151MT8(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-340DE151MT8(II) is a 340.0 W STC (315.7 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.62% efficiency, 41.1 V Voc at 25 C, and 45.03 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
315.7 W
Voc @ 25C
41.1 V
Efficiency
17.62%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-340DE151MT8(II) Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-340DE151MT8(II) handles rooftop heat (315.7 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-340DE151MT8(II) (Mono-c-Si) as a compact residential or specialty off-grid module delivering 176.2 W/m2 (2.29 percentage points below 19.91% CEC median). Compared against DualSun SAS DualSun 340M-120-00 (340.0 W), this model holds strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 16.46 A overcurrent floor served by a 20 A breaker.

Where Does Trina Solar TSM-340DE151MT8(II) Fall Across Listed CEC Models?

Where Trina Solar TSM-340DE151MT8(II) (340.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-340DE151MT8(II) (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-34: 340.0 W

What Dataset Percentiles Define Trina Solar TSM-340DE151MT8(II)?

Percentile placement of Trina Solar TSM-340DE151MT8(II) across power density (176.2 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-340DE151MT8(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-340DE151MT8(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention92.9%Module Efficiency17.62%

What Do the Dataset Ranks Show for Trina Solar TSM-340DE151MT8(II)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-340DE151MT8(II) specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,620

17.62% Aperture Efficiency

Power density 176.2 W/m2 (2.29 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.03 V at -10 C (585.4 V string) and 46.15 V at -20 C (13 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 46.3 m2 (499 sq ft) producing 7,577 W PTC; NEC 690.8 OCPD floor is 16.46 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.1 * (1 + (-0.273/100) * (-10 - 25)) = 45.03 V | OCPD = 1.56 * 10.55 = 16.46 A

Inputs from CEC Modules.csv for Trina Solar TSM-340DE151MT8(II): Voc=41.1 V, beta_Voc=-0.273%/C, Isc=10.55 A, STC=340.0 W, Area=1.93 m2.

Result: 13 panels max on 600 V (585.4 V); 24 panels for 8 kW (499 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-340DE151MT8(II)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-340DE151MT8(II).

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-340DE151MT8(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 315.7 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.2 V / 9.94 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.273 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.62% (1.93 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-340DE151MT8(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-340DE151MT8(II) (340.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 374 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 499 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 623 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-340DE151MT8(II) architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Trina Solar TSM-340DE151MT8(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-330DE151MT8(II) 330.0 W 306.2 W 40.6 V 33.8 V 17.1%
Trina Solar TSM-335DE151MT8(II) 335.0 W 311.0 W 40.7 V 34.0 V 17.36%
Trina Solar TSM-340DE151MT8(II) 340.0 W 315.7 W 41.1 V 34.2 V 17.62%
Trina Solar TSM-345DE151MT8(II) 345.0 W 320.5 W 41.2 V 34.5 V 17.88%

How Many Trina Solar TSM-340DE151MT8(II) Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-340DE151MT8(II) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.1V and beta_Voc=-0.273%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.15 V 13 panels 599.9 V 21 panels
-10 C (14 F) 45.03 V 13 panels 585.4 V 22 panels
0 C (32 F) 43.91 V 13 panels 570.8 V 22 panels
25 C (77 F STC) 41.1 V 14 panels 575.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-340DE151MT8(II)?

Alternative CEC solar modules from competing brands near Trina Solar TSM-340DE151MT8(II) (340.0 W), including DualSun SAS DualSun 340M-120-00.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 340M-120-00
DualSun SAS
340.0 W Tie (0 W) 40.1 V 18.78% 93.2%
Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W
Dehui Solar Power (Vietnam) CoLtd
335.0 W -5.0 W 40.8 V 20.81% 93.0%
Auxin Solar AXNG1M335B
Auxin Solar
335.0 W -5.0 W 40.75 V 20.43% 93.2%
Dehui Solar Power (Vietnam) CoLtd DH-M860W 335W
Dehui Solar Power (Vietnam) CoLtd
335.0 W -5.0 W 40.7 V 21.07% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-340DE151MT8(II)?

Evaluate Trina Solar TSM-340DE151MT8(II) (340.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-340DE151MT8(II) reaches 46.15 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 499 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (499 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-340DE151MT8(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-340DE151MT8(II) 8 kW Residential Fit

Needs 24 modules (499 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 340M-120-00.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 315.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-340DE151MT8(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-340DE151MT8(II)?

Multiplying Trina Solar TSM-340DE151MT8(II)'s 10.55 A short-circuit current by 1.56 equals 16.46 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Trina Solar TSM-340DE151MT8(II) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.03 V cold Voc at 14 F and handles 10.55 A Isc; string inverters cap Trina Solar TSM-340DE151MT8(II) at 13 panels on 600 V.

Is Trina Solar TSM-340DE151MT8(II) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-340DE151MT8(II) rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.