Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-335DD14A(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-335DD14A(II) is a 335.0 W STC (308.0 W PTC) Mono-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.26% efficiency, 46.3 V Voc at 25 C, and 51.1 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
308.0 W
Voc @ 25C
46.3 V
Efficiency
17.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-335DD14A(II) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-335DD14A(II) (Mono-c-Si) residential solar systems.

Homeowners evaluating Trina Solar TSM-335DD14A(II) need 18 panels for 6 kW or 24 panels (501 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft). Under NEC 690.7(A), beta_Voc (-0.296%/C) pushes open-circuit voltage to 51.1 V at 14 F and 52.47 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-335DD14A(II) Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-335DD14A(II) (335.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-335DD14A(II) (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-33: 335.0 W

What Dataset Percentiles Define Trina Solar TSM-335DD14A(II)?

Relative ranking of Trina Solar TSM-335DD14A(II) across nameplate watts, 91.9% PTC thermal ratio, and module aperture efficiency.

Trina Solar TSM-335DD14A(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-335DD14A(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention91.9%Module Efficiency17.26%

What Do the Dataset Ranks Show for Trina Solar TSM-335DD14A(II)?

Summary of Trina Solar TSM-335DD14A(II) output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,118

17.26% Aperture Efficiency

Power density 172.7 W/m2 (2.65 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.1 V at -10 C (562.1 V string) and 52.47 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 46.6 m2 (501 sq ft) producing 7,392 W PTC; NEC 690.8 OCPD floor is 14.6 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.3 * (1 + (-0.296/100) * (-10 - 25)) = 51.1 V | OCPD = 1.56 * 9.36 = 14.6 A

Inputs from CEC Modules.csv for Trina Solar TSM-335DD14A(II): Voc=46.3 V, beta_Voc=-0.296%/C, Isc=9.36 A, STC=335.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (562.1 V); 24 panels for 8 kW (501 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-335DD14A(II)?

Complete CEC test sheet for Trina Solar TSM-335DD14A(II) including Isc (9.36 A), Voc (46.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-335DD14A(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 308.0 W (91.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.36 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.0 V / 8.86 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.296 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.26% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-335DD14A(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-335DD14A(II).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 376 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 501 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 626 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-335DD14A(II) series guide.

Sibling CEC listings grouped into the Trina Solar TSM-335DD14A(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-325DD14A(II) 325.0 W 298.5 W 46.0 V 37.6 V 16.75%
Trina Solar TSM-330DD14A(II) 330.0 W 303.2 W 46.2 V 37.8 V 17.01%
Trina Solar TSM-335DD14A(II) 335.0 W 308.0 W 46.3 V 38.0 V 17.26%
Trina Solar TSM-340DD14A(II) 340.0 W 312.7 W 46.5 V 38.2 V 17.52%
Trina Solar TSM-345DD14A(II) 345.0 W 317.4 W 46.8 V 38.4 V 17.78%

How Many Trina Solar TSM-335DD14A(II) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-335DD14A(II) (46.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=46.3V and beta_Voc=-0.296%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.47 V 11 panels 577.2 V 19 panels
-10 C (14 F) 51.1 V 11 panels 562.1 V 19 panels
0 C (32 F) 49.73 V 12 panels 596.8 V 20 panels
25 C (77 F STC) 46.3 V 12 panels 555.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-335DD14A(II)?

Four comparable CEC modules such as AXITEC AC-335P/156-72S (335.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-335P/156-72S
AXITEC
335.0 W Tie (0 W) 46.2 V 17.26% 91.0%
Flextronics FXS-335BB-SAD1W
Flextronics
335.0 W Tie (0 W) 46.2 V 17.13% 91.2%
Boviet Solar Technology Co Ltd BVM6612M-335
Boviet Solar Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 91.7%
GCL System Integration Technology Co Ltd GCL-M6/72335
GCL System Integration Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-335DD14A(II)?

Evaluate Trina Solar TSM-335DD14A(II) (335.0 W STC, 46.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-335DD14A(II) reaches 52.47 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-335DD14A(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-335DD14A(II) 8 kW Residential Fit

Needs 24 modules (501 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-335P/156-72S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 308.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-335DD14A(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-335DD14A(II) PTC wattage (308.0 W) lower than STC (335.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 308.0 W PTC (91.9% retention) across Trina Solar TSM-335DD14A(II)'s 1.94 m2 aperture.

Who should skip Trina Solar TSM-335DD14A(II) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Trina Solar TSM-335DD14A(II) panels (501 sq ft) leave unusable roof gaps vs. AXITEC AC-335P/156-72S.

What is the 1,000 V commercial string limit for Trina Solar TSM-335DD14A(II)?

On 1,000 V commercial inverters at -10 C (51.1 V cold Voc), Trina Solar TSM-335DD14A(II) fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-335DD14A(II).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.