Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-305DD05A18(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-305DD05A18(II) is a 305.0 W STC (279.3 W PTC) Mono-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 18.6% efficiency, 40.2 V Voc at 25 C, and 44.36 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
305.0 W
PTC Wattage
279.3 W
Voc @ 25C
40.2 V
Efficiency
18.6%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-305DD05A18(II) Compare Against Peer CEC Listings?

Engineering position of Trina Solar TSM-305DD05A18(II) (305.0 W STC) vs. Enphase Energy Inc XACM-IQ7-LR6-60PB-305M across 5,889 CEC Mono-c-Si solar modules.

Ranking #16,131 across 21,677 CEC solar panels (below all-CEC median; higher than 23.9% of peers), Trina Solar TSM-305DD05A18(II) operates as a compact residential or specialty off-grid module sitting 105.0 W below the 410.0 W Mono-c-Si median. Mid-range 40.2 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677), 27 panels occupy 477 sq ft and offset roughly $2,060/yr at average US rates (or $3,483/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-305DD05A18(II) Fall Across Listed CEC Models?

Plots Trina Solar TSM-305DD05A18(II) at 305.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-305DD05A18(II) (305.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-30: 305.0 W

What Dataset Percentiles Define Trina Solar TSM-305DD05A18(II)?

Benchmarks Trina Solar TSM-305DD05A18(II) on STC wattage, thermal PTC/STC retention, and 18.6 aperture conversion efficiency against CEC peers.

Trina Solar TSM-305DD05A18(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-305DD05A18(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage305.0 WPTC/STC Retention91.6%Module Efficiency18.6%

What Do the Dataset Ranks Show for Trina Solar TSM-305DD05A18(II)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-305DD05A18(II) by Trina Solar.

Rank #16,131 / 21,677

305.0 W STC · Higher Than 23.9%

305.0 W STC (-80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,181

18.6% Aperture Efficiency

Power density 186.0 W/m2 (1.31 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.36 V at -10 C (576.7 V string) and 45.55 V at -20 C (13 max).

8 kW Reference Array

27 Panels = 8,235 W STC

Occupies 44.3 m2 (477 sq ft) producing 7,541 W PTC; NEC 690.8 OCPD floor is 15.16 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.2 * (1 + (-0.296/100) * (-10 - 25)) = 44.36 V | OCPD = 1.56 * 9.72 = 15.16 A

Inputs from CEC Modules.csv for Trina Solar TSM-305DD05A18(II): Voc=40.2 V, beta_Voc=-0.296%/C, Isc=9.72 A, STC=305.0 W, Area=1.64 m2.

Result: 13 panels max on 600 V (576.7 V); 27 panels for 8 kW (477 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-305DD05A18(II)?

Laboratory test ratings recorded for Trina Solar TSM-305DD05A18(II) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-305DD05A18(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 305.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 279.3 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.72 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.9 V / 9.28 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.296 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.6% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-305DD05A18(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (477 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-305DD05A18(II).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.1 kW 353 sq ft $1,527 $2,582
8 kW Class 27 8.23 kW 477 sq ft $2,060 $3,483
10 kW Class 33 10.06 kW 583 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Sibling wattage bins and frame colors grouped with Trina Solar TSM-305DD05A18(II) under Trina Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Trina Solar TSM-305DD05A18(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-300DD05A18(II) 300.0 W 270.6 W 39.9 V 32.6 V 18.33%
Trina Solar TSM-305DD05A18(II) 305.0 W 279.3 W 40.2 V 32.9 V 18.6%

How Many Trina Solar TSM-305DD05A18(II) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Trina Solar TSM-305DD05A18(II) (beta_Voc -0.296%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.2V and beta_Voc=-0.296%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.55 V 13 panels 592.1 V 21 panels
-10 C (14 F) 44.36 V 13 panels 576.7 V 22 panels
0 C (32 F) 43.17 V 13 panels 561.2 V 23 panels
25 C (77 F STC) 40.2 V 14 panels 562.8 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-305DD05A18(II)?

Closest cross-brand CEC competitors to Trina Solar TSM-305DD05A18(II) matched near 305.0 W STC and 40.2 V Voc, led by Enphase Energy Inc XACM-IQ7-LR6-60PB-305M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Enphase Energy Inc XACM-IQ7-LR6-60PB-305M
Enphase Energy Inc
305.0 W Tie (0 W) 40.2 V 19.3% 91.4%
DEHUI SOLAR POWER INC DH-60M-305W
DEHUI SOLAR POWER INC
305.0 W Tie (0 W) 40.3 V 18.94% 91.4%
DuCal Solar Technology LLC DST305M-60
DuCal Solar Technology LLC
305.0 W Tie (0 W) 40.0 V 18.75% 90.3%
AXITEC AC-305M/60S
AXITEC
305.0 W Tie (0 W) 39.81 V 18.75% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-305DD05A18(II)?

Evaluate Trina Solar TSM-305DD05A18(II) (305.0 W STC, 40.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-305DD05A18(II) reaches 45.55 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 477 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (477 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-305DD05A18(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-305DD05A18(II) 8 kW Residential Fit

Needs 27 modules (477 sq ft) with a 20 A string OCPD, offsetting ~$2,060/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Enphase Energy Inc XACM-IQ7-LR6-60PB-305M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-305DD05A18(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-305DD05A18(II) panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-305DD05A18(II) cold Voc rises from 40.2 V to 44.36 V (beta_Voc -0.296%/C), capping a 600 V string at 13 panels (576.7 V).

How much roof area does an 8 kW array of Trina Solar TSM-305DD05A18(II) need?

An 8 kW DC system uses 27 Trina Solar TSM-305DD05A18(II) modules (8,235 W STC / 7,541 W PTC), covering roughly 477 sq ft and saving ~$2,060/yr at 18.54 c/kWh.

How does Trina Solar TSM-305DD05A18(II) compare against Enphase Energy Inc XACM-IQ7-LR6-60PB-305M?

Trina Solar TSM-305DD05A18(II) outputs 305.0 W STC (40.2 V Voc, rank #16,131 of 21,677), while Enphase Energy Inc XACM-IQ7-LR6-60PB-305M delivers 305.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.