Trina Solar TSM-295DD05H(II) is a 295.0 W STC (275.6 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 17.99% efficiency, 39.5 V Voc at 25 C, and 43.32 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 275.6 W
- Voc @ 25C
- 39.5 V
- Efficiency
- 17.99%
How Does Trina Solar TSM-295DD05H(II) Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-295DD05H(II) (Mono-c-Si) residential solar systems.
Trina Solar TSM-295DD05H(II) delivers 179.9 W/m2 (1.92 percentage points below 19.91% CEC median) and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (494 sq ft). At -4 F (-20 C), string voltage climbs to 44.41 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with GCL System Integration Technology Co Ltd GCL-M6/60295 (295.0 W).
Where Does Trina Solar TSM-295DD05H(II) Fall Across Listed CEC Models?
Comparison of Trina Solar TSM-295DD05H(II) (295.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Trina Solar TSM-295DD05H(II)?
Relative ranking of Trina Solar TSM-295DD05H(II) across nameplate watts, 93.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Trina Solar TSM-295DD05H(II)?
Summary of Trina Solar TSM-295DD05H(II) output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.99% Aperture Efficiency
Power density 179.9 W/m2 (1.92 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.32 V at -10 C (563.2 V string) and 44.41 V at -20 C (13 max).
28 Panels = 8,260 W STC
Occupies 45.9 m2 (494 sq ft) producing 7,717 W PTC; NEC 690.8 OCPD floor is 15.05 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.5 * (1 + (-0.276/100) * (-10 - 25)) = 43.32 V | OCPD = 1.56 * 9.65 = 15.05 A
Inputs from CEC Modules.csv for Trina Solar TSM-295DD05H(II): Voc=39.5 V, beta_Voc=-0.276%/C, Isc=9.65 A, STC=295.0 W, Area=1.64 m2.
Result: 13 panels max on 600 V (563.2 V); 28 panels for 8 kW (494 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-295DD05H(II)?
Complete CEC test sheet for Trina Solar TSM-295DD05H(II) including Isc (9.65 A), Voc (39.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 275.6 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.09 V / 9.19 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.276 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.99% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 40 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-295DD05H(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-295DD05H(II).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 371 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 494 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 600 sq ft | $2,510 | $4,245 |
How Many Trina Solar TSM-295DD05H(II) Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Trina Solar TSM-295DD05H(II) (39.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.41 V | 13 panels | 577.3 V | 22 panels |
| -10 C (14 F) | 43.32 V | 13 panels | 563.2 V | 23 panels |
| 0 C (32 F) | 42.23 V | 14 panels | 591.2 V | 23 panels |
| 25 C (77 F STC) | 39.5 V | 15 panels | 592.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-295DD05H(II)?
Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-M6/60295 (295.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60295 GCL System Integration Technology Co Ltd |
295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| CSI Solar Co Ltd CS3K-295MS CSI Solar Co Ltd |
295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| AXITEC AC-290M/60S AXITEC |
290.0 W | -5.0 W | 39.42 V | 17.79% | 91.1% |
| AXITEC AC-290M/60V AXITEC |
290.0 W | -5.0 W | 39.42 V | 17.79% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-295DD05H(II)?
Evaluate Trina Solar TSM-295DD05H(II) (295.0 W STC, 39.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-295DD05H(II) reaches 44.41 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 494 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (494 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-295DD05H(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-295DD05H(II) 8 kW Residential Fit
Needs 28 modules (494 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 275.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-295DD05H(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Trina Solar TSM-295DD05H(II) panels fit on a 600 V winter solar string?
At -10 C (14 F), Trina Solar TSM-295DD05H(II) cold Voc rises from 39.5 V to 43.32 V (beta_Voc -0.276%/C), capping a 600 V string at 13 panels (563.2 V).
How much roof area does an 8 kW array of Trina Solar TSM-295DD05H(II) need?
An 8 kW DC system uses 28 Trina Solar TSM-295DD05H(II) modules (8,260 W STC / 7,717 W PTC), covering roughly 494 sq ft and saving ~$2,067/yr at 18.54 c/kWh.
How does Trina Solar TSM-295DD05H(II) compare against GCL System Integration Technology Co Ltd GCL-M6/60295?
Trina Solar TSM-295DD05H(II) outputs 295.0 W STC (39.5 V Voc, rank #16,890 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/60295 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)