Trina Solar TSM-285PD1410 is a 285.0 W STC (258.1 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.84% efficiency, 44.5 V Voc at 25 C, and 50.11 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 258.1 W
- Voc @ 25C
- 44.5 V
- Efficiency
- 14.84%
How Does Trina Solar TSM-285PD1410 Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-285PD1410: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Measured at 285.0 W STC and 258.1 W PTC, Trina Solar TSM-285PD1410 sits -100.0 W vs all-CEC median (below all-CEC median; higher than 17.3% of peers) among 21,677 listed modules. Power density reaches 148.4 W/m2 (5.07 percentage points below 19.91% CEC median). Mid-range 44.5 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer AXITEC AC-285P/156-72S rates 285.0 W.
Where Does Trina Solar TSM-285PD1410 Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-285PD1410 (285.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define Trina Solar TSM-285PD1410?
Dataset percentiles tracking Trina Solar TSM-285PD1410 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for Trina Solar TSM-285PD1410?
Benchmark highlights for Trina Solar TSM-285PD1410 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.84% Aperture Efficiency
Power density 148.4 W/m2 (5.07 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.11 V at -10 C (551.2 V string) and 51.71 V at -20 C (11 max).
29 Panels = 8,265 W STC
Occupies 55.7 m2 (600 sq ft) producing 7,485 W PTC; NEC 690.8 OCPD floor is 13.24 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.5 * (1 + (-0.36/100) * (-10 - 25)) = 50.11 V | OCPD = 1.56 * 8.49 = 13.24 A
Inputs from CEC Modules.csv for Trina Solar TSM-285PD1410: Voc=44.5 V, beta_Voc=-0.36%/C, Isc=8.49 A, STC=285.0 W, Area=1.921 m2.
Result: 11 panels max on 600 V (551.2 V); 29 panels for 8 kW (600 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-285PD1410?
Official CEC datasheet figures for Trina Solar TSM-285PD1410 (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 258.1 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.49 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.25 V / 7.86 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.84% (1.921 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-285PD1410 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-285PD1410 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 455 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 600 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 744 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-285PD1410 mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-275PD1410 | 275.0 W | 248.9 W | 44.4 V | 35.85 V | 14.32% |
| Trina Solar TSM-280PD1410 | 280.0 W | 253.5 W | 44.44 V | 36.01 V | 14.58% |
| Trina Solar TSM-285PD1410 | 285.0 W | 258.1 W | 44.5 V | 36.25 V | 14.84% |
| Trina Solar TSM-290PD1410 | 290.0 W | 262.8 W | 44.9 V | 36.4 V | 15.1% |
| Trina Solar TSM-295PD1410 | 295.0 W | 266.9 W | 45.0 V | 36.5 V | 15.36% |
How Many Trina Solar TSM-285PD1410 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-285PD1410 (50.11 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.71 V | 11 panels | 568.8 V | 19 panels |
| -10 C (14 F) | 50.11 V | 11 panels | 551.2 V | 19 panels |
| 0 C (32 F) | 48.51 V | 12 panels | 582.1 V | 20 panels |
| 25 C (77 F STC) | 44.5 V | 13 panels | 578.5 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-285PD1410?
Competing CEC solar panels closest to Trina Solar TSM-285PD1410 in nameplate wattage and Voc, starting with AXITEC AC-285P/156-72S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-285P/156-72S AXITEC |
285.0 W | Tie (0 W) | 44.51 V | 14.72% | 90.0% |
| Gintung Energy ASEC-285G6M Gintung Energy |
285.0 W | Tie (0 W) | 44.53 V | 14.57% | 89.5% |
| Centrosolar America DP72 285 Centrosolar America |
285.0 W | Tie (0 W) | 44.32 V | 14.66% | 88.5% |
| Gintung Energy ASEC-285G6S Gintung Energy |
285.0 W | Tie (0 W) | 44.69 V | 14.57% | 89.7% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-285PD1410?
Evaluate Trina Solar TSM-285PD1410 (285.0 W STC, 44.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-285PD1410 reaches 51.71 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 600 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (600 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-285PD1410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-285PD1410 8 kW Residential Fit
Needs 29 modules (600 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-285P/156-72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 258.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-285PD1410 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Trina Solar TSM-285PD1410 panels fit on a 600 V winter solar string?
At -10 C (14 F), Trina Solar TSM-285PD1410 cold Voc rises from 44.5 V to 50.11 V (beta_Voc -0.36%/C), capping a 600 V string at 11 panels (551.2 V).
How much roof area does an 8 kW array of Trina Solar TSM-285PD1410 need?
An 8 kW DC system uses 29 Trina Solar TSM-285PD1410 modules (8,265 W STC / 7,485 W PTC), covering roughly 600 sq ft and saving ~$2,070/yr at 18.54 c/kWh.
How does Trina Solar TSM-285PD1410 compare against AXITEC AC-285P/156-72S?
Trina Solar TSM-285PD1410 outputs 285.0 W STC (44.5 V Voc, rank #17,598 of 21,677), while AXITEC AC-285P/156-72S delivers 285.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)