Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-285PD1408 is a 285.0 W STC (258.1 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.84% efficiency, 44.8 V Voc at 25 C, and 50.44 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
258.1 W
Voc @ 25C
44.8 V
Efficiency
14.84%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-285PD1408 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-285PD1408 (Multi-c-Si) residential solar systems.

Homeowners evaluating Trina Solar TSM-285PD1408 need 22 panels for 6 kW or 29 panels (600 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (600 sq ft). Under NEC 690.7(A), beta_Voc (-0.36%/C) pushes open-circuit voltage to 50.44 V at 14 F and 52.06 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-285PD1408 Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-285PD1408 (285.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-285PD1408 (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-28: 285.0 W

What Dataset Percentiles Define Trina Solar TSM-285PD1408?

Relative ranking of Trina Solar TSM-285PD1408 across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Trina Solar TSM-285PD1408 Engineering BenchmarksPercentile comparison of Trina Solar TSM-285PD1408 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention90.6%Module Efficiency14.84%

What Do the Dataset Ranks Show for Trina Solar TSM-285PD1408?

Summary of Trina Solar TSM-285PD1408 output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,966

14.84% Aperture Efficiency

Power density 148.4 W/m2 (5.07 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.44 V at -10 C (554.8 V string) and 52.06 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 55.7 m2 (600 sq ft) producing 7,485 W PTC; NEC 690.8 OCPD floor is 13.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.36/100) * (-10 - 25)) = 50.44 V | OCPD = 1.56 * 8.36 = 13.04 A

Inputs from CEC Modules.csv for Trina Solar TSM-285PD1408: Voc=44.8 V, beta_Voc=-0.36%/C, Isc=8.36 A, STC=285.0 W, Area=1.921 m2.

Result: 11 panels max on 600 V (554.8 V); 29 panels for 8 kW (600 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-285PD1408?

Complete CEC test sheet for Trina Solar TSM-285PD1408 including Isc (8.36 A), Voc (44.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-285PD1408.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 258.1 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.36 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.3 V / 7.86 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.84% (1.921 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-285PD1408 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-285PD1408.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 455 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 600 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 744 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-285PD1408 series guide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Trina Solar TSM-285PD1408 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-275PD1408 275.0 W 248.9 W 44.3 V 35.6 V 14.32%
Trina Solar TSM-280PD1408 280.0 W 253.5 W 44.4 V 36.0 V 14.58%
Trina Solar TSM-285PD1408 285.0 W 258.1 W 44.8 V 36.3 V 14.84%
Trina Solar TSM-290PD1408 290.0 W 262.8 W 44.9 V 36.4 V 15.1%
Trina Solar TSM-295PD1408 295.0 W 266.9 W 45.0 V 36.5 V 15.36%

How Many Trina Solar TSM-285PD1408 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-285PD1408 (44.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.8V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.06 V 11 panels 572.7 V 19 panels
-10 C (14 F) 50.44 V 11 panels 554.8 V 19 panels
0 C (32 F) 48.83 V 12 panels 586.0 V 20 panels
25 C (77 F STC) 44.8 V 13 panels 582.4 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-285PD1408?

Four comparable CEC modules such as Gintung Energy ASEC-285G6S (285.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-285G6S
Gintung Energy
285.0 W Tie (0 W) 44.69 V 14.57% 89.7%
Gintung Energy ASEC-285G6M
Gintung Energy
285.0 W Tie (0 W) 44.53 V 14.57% 89.5%
AXITEC AC-285P/156-72S
AXITEC
285.0 W Tie (0 W) 44.51 V 14.72% 90.0%
Centrosolar America DP72 285
Centrosolar America
285.0 W Tie (0 W) 44.32 V 14.66% 88.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-285PD1408?

Evaluate Trina Solar TSM-285PD1408 (285.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-285PD1408 reaches 52.06 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 600 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (600 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-285PD1408 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-285PD1408 8 kW Residential Fit

Needs 29 modules (600 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-285G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 258.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-285PD1408 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-285PD1408 PTC wattage (258.1 W) lower than STC (285.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 258.1 W PTC (90.6% retention) across Trina Solar TSM-285PD1408's 1.921 m2 aperture.

Who should skip Trina Solar TSM-285PD1408 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Trina Solar TSM-285PD1408 panels (600 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-285G6S.

What is the 1,000 V commercial string limit for Trina Solar TSM-285PD1408?

On 1,000 V commercial inverters at -10 C (50.44 V cold Voc), Trina Solar TSM-285PD1408 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-285PD1408.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.