Trina Solar TSM-280DD061M18(II) is a 280.0 W STC (259.0 W PTC) Mono-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.28% efficiency, 33.3 V Voc at 25 C, and 36.39 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 280.0 W
- PTC Wattage
- 259.0 W
- Voc @ 25C
- 33.3 V
- Efficiency
- 17.28%
How Does Trina Solar TSM-280DD061M18(II) Compare Against Peer CEC Listings?
Engineering position of Trina Solar TSM-280DD061M18(II) (280.0 W STC) vs. CSI Solar Co Ltd CS6PH-280P across 5,889 CEC Mono-c-Si solar modules.
Ranking #17,941 across 21,677 CEC solar panels (below all-CEC median; higher than 15.8% of peers), Trina Solar TSM-280DD061M18(II) operates as a compact residential or specialty off-grid module sitting 130.0 W below the 410.0 W Mono-c-Si median. Lower 33.3 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters. With strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677), 29 panels occupy 506 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Trina Solar TSM-280DD061M18(II) Fall Across Listed CEC Models?
Plots Trina Solar TSM-280DD061M18(II) at 280.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Trina Solar TSM-280DD061M18(II)?
Benchmarks Trina Solar TSM-280DD061M18(II) on STC wattage, thermal PTC/STC retention, and 17.28 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Trina Solar TSM-280DD061M18(II)?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-280DD061M18(II) by Trina Solar.
280.0 W STC · Higher Than 15.8%
280.0 W STC (-105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.28% Aperture Efficiency
Power density 172.8 W/m2 (2.63 percentage points below 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 36.39 V at -10 C (582.2 V string) and 37.27 V at -20 C (16 max).
29 Panels = 8,120 W STC
Occupies 47.0 m2 (506 sq ft) producing 7,511 W PTC; NEC 690.8 OCPD floor is 16.54 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 33.3 * (1 + (-0.265/100) * (-10 - 25)) = 36.39 V | OCPD = 1.56 * 10.6 = 16.54 A
Inputs from CEC Modules.csv for Trina Solar TSM-280DD061M18(II): Voc=33.3 V, beta_Voc=-0.265%/C, Isc=10.6 A, STC=280.0 W, Area=1.62 m2.
Result: 16 panels max on 600 V (582.2 V); 29 panels for 8 kW (506 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-280DD061M18(II)?
Laboratory test ratings recorded for Trina Solar TSM-280DD061M18(II) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 259.0 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 33.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 27.8 V / 10.09 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.265 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.28% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-280DD061M18(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (506 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-280DD061M18(II).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.16 kW | 384 sq ft | $1,542 | $2,607 |
| 8 kW Class | 29 | 8.12 kW | 506 sq ft | $2,032 | $3,437 |
| 10 kW Class | 36 | 10.08 kW | 628 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Sibling wattage bins and frame colors grouped with Trina Solar TSM-280DD061M18(II) under Trina Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-275DD061M18(II) | 275.0 W | 254.3 W | 33.2 V | 27.6 V | 16.98% |
| Trina Solar TSM-280DD061M18(II) | 280.0 W | 259.0 W | 33.3 V | 27.8 V | 17.28% |
| Trina Solar TSM-285DD061M18(II) | 285.0 W | 263.8 W | 33.6 V | 28.0 V | 17.59% |
How Many Trina Solar TSM-280DD061M18(II) Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Trina Solar TSM-280DD061M18(II) (beta_Voc -0.265%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 37.27 V | 16 panels | 596.3 V | 26 panels |
| -10 C (14 F) | 36.39 V | 16 panels | 582.2 V | 27 panels |
| 0 C (32 F) | 35.51 V | 16 panels | 568.2 V | 28 panels |
| 25 C (77 F STC) | 33.3 V | 18 panels | 599.4 V | 30 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-280DD061M18(II)?
Closest cross-brand CEC competitors to Trina Solar TSM-280DD061M18(II) matched near 280.0 W STC and 33.3 V Voc, led by CSI Solar Co Ltd CS6PH-280P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6PH-280P CSI Solar Co Ltd |
280.0 W | Tie (0 W) | 35.4 V | 18.06% | 93.0% |
| CSI Solar Co Ltd CS6P-280M CSI Solar Co Ltd |
280.0 W | Tie (0 W) | 38.5 V | 18.08% | 90.8% |
| CSI Solar Co Ltd CS6P-280MX CSI Solar Co Ltd |
280.0 W | Tie (0 W) | 38.5 V | 18.08% | 90.8% |
| GermanSolar USA Inc GSP-280W GermanSolar USA Inc |
280.0 W | Tie (0 W) | 38.55 V | 16.87% | 92.1% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-280DD061M18(II)?
Evaluate Trina Solar TSM-280DD061M18(II) (280.0 W STC, 33.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-280DD061M18(II) reaches 37.27 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 506 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (506 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-280DD061M18(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-280DD061M18(II) 8 kW Residential Fit
Needs 29 modules (506 sq ft) with a 20 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare CSI Solar Co Ltd CS6PH-280P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 259.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-280DD061M18(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Trina Solar TSM-280DD061M18(II) panels fit on a 600 V winter solar string?
At -10 C (14 F), Trina Solar TSM-280DD061M18(II) cold Voc rises from 33.3 V to 36.39 V (beta_Voc -0.265%/C), capping a 600 V string at 16 panels (582.2 V).
How much roof area does an 8 kW array of Trina Solar TSM-280DD061M18(II) need?
An 8 kW DC system uses 29 Trina Solar TSM-280DD061M18(II) modules (8,120 W STC / 7,511 W PTC), covering roughly 506 sq ft and saving ~$2,032/yr at 18.54 c/kWh.
How does Trina Solar TSM-280DD061M18(II) compare against CSI Solar Co Ltd CS6PH-280P?
Trina Solar TSM-280DD061M18(II) outputs 280.0 W STC (33.3 V Voc, rank #17,941 of 21,677), while CSI Solar Co Ltd CS6PH-280P delivers 280.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)