Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-280DD061M08(II) is a 280.0 W STC (259.0 W PTC) Mono-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.28% efficiency, 33.3 V Voc at 25 C, and 36.39 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
280.0 W
PTC Wattage
259.0 W
Voc @ 25C
33.3 V
Efficiency
17.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-280DD061M08(II) Compare Against Peer CEC Listings?

Solar engineering breakdown for Trina Solar TSM-280DD061M08(II): PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Trina Solar and peers, Trina Solar TSM-280DD061M08(II) stands 130.0 W below the 410.0 W Mono-c-Si median and strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,542-$2,523/yr in baseline US bill offset. Lower 33.3 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.

Where Does Trina Solar TSM-280DD061M08(II) Fall Across Listed CEC Models?

Distribution marker showing Trina Solar TSM-280DD061M08(II) (280.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-280DD061M08(II) (280.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-28: 280.0 W

What Dataset Percentiles Define Trina Solar TSM-280DD061M08(II)?

Dataset percentiles tracking Trina Solar TSM-280DD061M08(II) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Trina Solar TSM-280DD061M08(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-280DD061M08(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage280.0 WPTC/STC Retention92.5%Module Efficiency17.28%

What Do the Dataset Ranks Show for Trina Solar TSM-280DD061M08(II)?

Benchmark highlights for Trina Solar TSM-280DD061M08(II) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #17,941 / 21,677

280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,057

17.28% Aperture Efficiency

Power density 172.8 W/m2 (2.63 percentage points below 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 36.39 V at -10 C (582.2 V string) and 37.27 V at -20 C (16 max).

8 kW Reference Array

29 Panels = 8,120 W STC

Occupies 47.0 m2 (506 sq ft) producing 7,511 W PTC; NEC 690.8 OCPD floor is 16.54 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.3 * (1 + (-0.265/100) * (-10 - 25)) = 36.39 V | OCPD = 1.56 * 10.6 = 16.54 A

Inputs from CEC Modules.csv for Trina Solar TSM-280DD061M08(II): Voc=33.3 V, beta_Voc=-0.265%/C, Isc=10.6 A, STC=280.0 W, Area=1.62 m2.

Result: 16 panels max on 600 V (582.2 V); 29 panels for 8 kW (506 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-280DD061M08(II)?

Official CEC datasheet figures for Trina Solar TSM-280DD061M08(II) (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-280DD061M08(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 280.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 259.0 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 27.8 V / 10.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.265 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.28% (1.62 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-280DD061M08(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Trina Solar TSM-280DD061M08(II) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.16 kW 384 sq ft $1,542 $2,607
8 kW Class 29 8.12 kW 506 sq ft $2,032 $3,437
10 kW Class 36 10.08 kW 628 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-280DD061M08(II) mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Trina Solar TSM-280DD061M08(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-275DD061M08(II) 275.0 W 254.3 W 33.2 V 27.6 V 16.98%
Trina Solar TSM-280DD061M08(II) 280.0 W 259.0 W 33.3 V 27.8 V 17.28%
Trina Solar TSM-285DD061M08(II) 285.0 W 263.8 W 33.6 V 28.0 V 17.59%

How Many Trina Solar TSM-280DD061M08(II) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-280DD061M08(II) (36.39 V at 14 F).

Computed from Voc=33.3V and beta_Voc=-0.265%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 37.27 V 16 panels 596.3 V 26 panels
-10 C (14 F) 36.39 V 16 panels 582.2 V 27 panels
0 C (32 F) 35.51 V 16 panels 568.2 V 28 panels
25 C (77 F STC) 33.3 V 18 panels 599.4 V 30 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-280DD061M08(II)?

Competing CEC solar panels closest to Trina Solar TSM-280DD061M08(II) in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6PH-280P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6PH-280P
CSI Solar Co Ltd
280.0 W Tie (0 W) 35.4 V 18.06% 93.0%
CSI Solar Co Ltd CS6P-280M
CSI Solar Co Ltd
280.0 W Tie (0 W) 38.5 V 18.08% 90.8%
CSI Solar Co Ltd CS6P-280MX
CSI Solar Co Ltd
280.0 W Tie (0 W) 38.5 V 18.08% 90.8%
GermanSolar USA Inc GSP-280W
GermanSolar USA Inc
280.0 W Tie (0 W) 38.55 V 16.87% 92.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-280DD061M08(II)?

Evaluate Trina Solar TSM-280DD061M08(II) (280.0 W STC, 33.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-280DD061M08(II) reaches 37.27 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 506 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (506 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-280DD061M08(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-280DD061M08(II) 8 kW Residential Fit

Needs 29 modules (506 sq ft) with a 20 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare CSI Solar Co Ltd CS6PH-280P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 259.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-280DD061M08(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-280DD061M08(II)?

Multiplying Trina Solar TSM-280DD061M08(II)'s 10.6 A short-circuit current by 1.56 equals 16.54 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Trina Solar TSM-280DD061M08(II) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 36.39 V cold Voc at 14 F and handles 10.6 A Isc; string inverters cap Trina Solar TSM-280DD061M08(II) at 16 panels on 600 V.

Is Trina Solar TSM-280DD061M08(II) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-280DD061M08(II) rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.