Trina Solar TSM-270DD09M4C18 is a 270.0 W STC (250.7 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.67% efficiency, 38.7 V Voc at 25 C, and 42.15 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 250.7 W
- Voc @ 25C
- 38.7 V
- Efficiency
- 16.67%
How Does Trina Solar TSM-270DD09M4C18 Compare Against Peer CEC Listings?
How Trina Solar Trina Solar TSM-270DD09M4C18 handles rooftop heat (250.7 W PTC), 8 kW sizing, and cold winter string voltage.
Trina Solar builds the Trina Solar TSM-270DD09M4C18 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 166.7 W/m2 (3.24 percentage points below 19.91% CEC median). Compared against Centrosolar America EM60 270SW (270.0 W), this model holds strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Lower 38.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.92 A overcurrent floor served by a 15 A breaker.
Where Does Trina Solar TSM-270DD09M4C18 Fall Across Listed CEC Models?
Where Trina Solar TSM-270DD09M4C18 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Trina Solar TSM-270DD09M4C18?
Percentile placement of Trina Solar TSM-270DD09M4C18 across power density (166.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Trina Solar TSM-270DD09M4C18?
Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-270DD09M4C18 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.67% Aperture Efficiency
Power density 166.7 W/m2 (3.24 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.15 V at -10 C (590.1 V string) and 43.14 V at -20 C (13 max).
30 Panels = 8,100 W STC
Occupies 48.6 m2 (523 sq ft) producing 7,521 W PTC; NEC 690.8 OCPD floor is 13.92 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.7 * (1 + (-0.255/100) * (-10 - 25)) = 42.15 V | OCPD = 1.56 * 8.92 = 13.92 A
Inputs from CEC Modules.csv for Trina Solar TSM-270DD09M4C18: Voc=38.7 V, beta_Voc=-0.255%/C, Isc=8.92 A, STC=270.0 W, Area=1.62 m2.
Result: 14 panels max on 600 V (590.1 V); 30 panels for 8 kW (523 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-270DD09M4C18?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-270DD09M4C18.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 250.7 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.92 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.9 V / 8.46 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.255 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.67% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 56 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-270DD09M4C18 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-270DD09M4C18 (270.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 401 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 523 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 663 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-270DD09M4C18 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-265DD09M4C18 | 265.0 W | 245.9 W | 38.5 V | 31.7 V | 16.36% |
| Trina Solar TSM-270DD09M4C18 | 270.0 W | 250.7 W | 38.7 V | 31.9 V | 16.67% |
How Many Trina Solar TSM-270DD09M4C18 Modules Fit in a Cold-Weather String?
Maximum series module counts for Trina Solar TSM-270DD09M4C18 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.14 V | 13 panels | 560.8 V | 23 panels |
| -10 C (14 F) | 42.15 V | 14 panels | 590.1 V | 23 panels |
| 0 C (32 F) | 41.17 V | 14 panels | 576.4 V | 24 panels |
| 25 C (77 F STC) | 38.7 V | 15 panels | 580.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-270DD09M4C18?
Alternative CEC solar modules from competing brands near Trina Solar TSM-270DD09M4C18 (270.0 W), including Centrosolar America EM60 270SW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America EM60 270SW Centrosolar America |
270.0 W | Tie (0 W) | 38.68 V | 16.76% | 91.3% |
| Ablytek 6MN6A270 Ablytek |
270.0 W | Tie (0 W) | 38.63 V | 16.6% | 89.7% |
| DEHUI SOLAR POWER INC DH-60M-270W DEHUI SOLAR POWER INC |
270.0 W | Tie (0 W) | 38.57 V | 16.77% | 91.1% |
| Flextronics FXS-270BB-SAC1B Flextronics |
270.0 W | Tie (0 W) | 38.5 V | 16.45% | 91.3% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-270DD09M4C18?
Evaluate Trina Solar TSM-270DD09M4C18 (270.0 W STC, 38.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-270DD09M4C18 reaches 43.14 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (523 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-270DD09M4C18 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-270DD09M4C18 8 kW Residential Fit
Needs 30 modules (523 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America EM60 270SW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-270DD09M4C18 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-270DD09M4C18?
Multiplying Trina Solar TSM-270DD09M4C18's 8.92 A short-circuit current by 1.56 equals 13.92 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Trina Solar TSM-270DD09M4C18 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.15 V cold Voc at 14 F and handles 8.92 A Isc; string inverters cap Trina Solar TSM-270DD09M4C18 at 14 panels on 600 V.
Is Trina Solar TSM-270DD09M4C18 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-270DD09M4C18 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)