Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-270DD05A — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-270DD05A is a 270.0 W STC (246.4 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.57% efficiency, 38.6 V Voc at 25 C, and 42.6 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
246.4 W
Voc @ 25C
38.6 V
Efficiency
16.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-270DD05A Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-270DD05A handles rooftop heat (246.4 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-270DD05A (Mono-c-Si) as a compact residential or specialty off-grid module delivering 165.6 W/m2 (3.34 percentage points below 19.91% CEC median). Compared against Ablytek 6MN6A270 (270.0 W), this model holds typical 91.3% PTC-to-STC thermal output (246.4 W real-world rating). Lower 38.6 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.4 A overcurrent floor served by a 15 A breaker.

Where Does Trina Solar TSM-270DD05A Fall Across Listed CEC Models?

Where Trina Solar TSM-270DD05A (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-270DD05A (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-27: 270.0 W

What Dataset Percentiles Define Trina Solar TSM-270DD05A?

Percentile placement of Trina Solar TSM-270DD05A across power density (165.6 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-270DD05A Engineering BenchmarksPercentile comparison of Trina Solar TSM-270DD05A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention91.3%Module Efficiency16.57%

What Do the Dataset Ranks Show for Trina Solar TSM-270DD05A?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-270DD05A specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,184

16.57% Aperture Efficiency

Power density 165.6 W/m2 (3.34 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.6 V at -10 C (596.4 V string) and 43.74 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 48.9 m2 (526 sq ft) producing 7,392 W PTC; NEC 690.8 OCPD floor is 14.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.6 * (1 + (-0.296/100) * (-10 - 25)) = 42.6 V | OCPD = 1.56 * 9.23 = 14.4 A

Inputs from CEC Modules.csv for Trina Solar TSM-270DD05A: Voc=38.6 V, beta_Voc=-0.296%/C, Isc=9.23 A, STC=270.0 W, Area=1.63 m2.

Result: 14 panels max on 600 V (596.4 V); 30 panels for 8 kW (526 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-270DD05A?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-270DD05A.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-270DD05A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 246.4 W (91.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.8 V / 8.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.296 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.57% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-270DD05A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-270DD05A (270.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 404 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 526 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 667 sq ft $2,568 $4,342

How Many Trina Solar TSM-270DD05A Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-270DD05A from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.6V and beta_Voc=-0.296%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.74 V 13 panels 568.6 V 22 panels
-10 C (14 F) 42.6 V 14 panels 596.4 V 23 panels
0 C (32 F) 41.46 V 14 panels 580.4 V 24 panels
25 C (77 F STC) 38.6 V 15 panels 579.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-270DD05A?

Alternative CEC solar modules from competing brands near Trina Solar TSM-270DD05A (270.0 W), including Ablytek 6MN6A270. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Ablytek 6MN6A270
Ablytek
270.0 W Tie (0 W) 38.63 V 16.6% 89.7%
DEHUI SOLAR POWER INC DH-60M-270W
DEHUI SOLAR POWER INC
270.0 W Tie (0 W) 38.57 V 16.77% 91.1%
Centrosolar America EM60 270SW
Centrosolar America
270.0 W Tie (0 W) 38.68 V 16.76% 91.3%
Flextronics FXS-270BB-SAC1B
Flextronics
270.0 W Tie (0 W) 38.5 V 16.45% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-270DD05A?

Evaluate Trina Solar TSM-270DD05A (270.0 W STC, 38.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-270DD05A reaches 43.74 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 526 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (526 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-270DD05A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-270DD05A 8 kW Residential Fit

Needs 30 modules (526 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Ablytek 6MN6A270.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 246.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-270DD05A by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-270DD05A?

Multiplying Trina Solar TSM-270DD05A's 9.23 A short-circuit current by 1.56 equals 14.4 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Trina Solar TSM-270DD05A pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.6 V cold Voc at 14 F and handles 9.23 A Isc; string inverters cap Trina Solar TSM-270DD05A at 14 panels on 600 V.

Is Trina Solar TSM-270DD05A eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-270DD05A rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.