Trina Solar TSM-265PD05102 is a 265.0 W STC (243.2 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.37% efficiency, 38.3 V Voc at 25 C, and 42.72 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 265.0 W
- PTC Wattage
- 243.2 W
- Voc @ 25C
- 38.3 V
- Efficiency
- 16.37%
How Does Trina Solar TSM-265PD05102 Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-265PD05102: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Measured at 265.0 W STC and 243.2 W PTC, Trina Solar TSM-265PD05102 sits -120.0 W vs all-CEC median (below all-CEC median; higher than 11.7% of peers) among 21,677 listed modules. Power density reaches 163.8 W/m2 (3.54 percentage points below 19.91% CEC median). Lower 38.3 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Centrosolar America CP60 265-C1 rates 265.0 W.
Where Does Trina Solar TSM-265PD05102 Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-265PD05102 (265.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define Trina Solar TSM-265PD05102?
Dataset percentiles tracking Trina Solar TSM-265PD05102 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for Trina Solar TSM-265PD05102?
Benchmark highlights for Trina Solar TSM-265PD05102 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
265.0 W STC · Higher Than 11.7%
265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.37% Aperture Efficiency
Power density 163.8 W/m2 (3.54 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.72 V at -10 C (598.1 V string) and 43.99 V at -20 C (13 max).
31 Panels = 8,215 W STC
Occupies 50.2 m2 (540 sq ft) producing 7,539 W PTC; NEC 690.8 OCPD floor is 14.2 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.3 * (1 + (-0.33/100) * (-10 - 25)) = 42.72 V | OCPD = 1.56 * 9.1 = 14.2 A
Inputs from CEC Modules.csv for Trina Solar TSM-265PD05102: Voc=38.3 V, beta_Voc=-0.33%/C, Isc=9.1 A, STC=265.0 W, Area=1.618 m2.
Result: 14 panels max on 600 V (598.1 V); 31 panels for 8 kW (540 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-265PD05102?
Official CEC datasheet figures for Trina Solar TSM-265PD05102 (Multi-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 243.2 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.8 V / 8.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.37% (1.618 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-265PD05102 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-265PD05102 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.09 kW | 401 sq ft | $1,524 | $2,577 |
| 8 kW Class | 31 | 8.21 kW | 540 sq ft | $2,055 | $3,475 |
| 10 kW Class | 38 | 10.07 kW | 662 sq ft | $2,520 | $4,262 |
How Many Trina Solar TSM-265PD05102 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-265PD05102 (42.72 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.99 V | 13 panels | 571.9 V | 22 panels |
| -10 C (14 F) | 42.72 V | 14 panels | 598.1 V | 23 panels |
| 0 C (32 F) | 41.46 V | 14 panels | 580.4 V | 24 panels |
| 25 C (77 F STC) | 38.3 V | 15 panels | 574.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-265PD05102?
Competing CEC solar panels closest to Trina Solar TSM-265PD05102 in nameplate wattage and Voc, starting with Centrosolar America CP60 265-C1.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America CP60 265-C1 Centrosolar America |
265.0 W | Tie (0 W) | 38.3 V | 16.29% | 90.4% |
| GermanSolar USA GSM6-60-265W GermanSolar USA |
265.0 W | Tie (0 W) | 38.3 V | 16.29% | 90.5% |
| Centrosolar America EM60 265BB Centrosolar America |
265.0 W | Tie (0 W) | 38.29 V | 16.45% | 91.0% |
| Centrosolar America EP60 265BW Centrosolar America |
265.0 W | Tie (0 W) | 38.29 V | 16.45% | 91.2% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-265PD05102?
Evaluate Trina Solar TSM-265PD05102 (265.0 W STC, 38.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-265PD05102 reaches 43.99 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 540 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (540 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-265PD05102 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-265PD05102 8 kW Residential Fit
Needs 31 modules (540 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America CP60 265-C1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 243.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-265PD05102 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Trina Solar TSM-265PD05102 panels fit on a 600 V winter solar string?
At -10 C (14 F), Trina Solar TSM-265PD05102 cold Voc rises from 38.3 V to 42.72 V (beta_Voc -0.33%/C), capping a 600 V string at 14 panels (598.1 V).
How much roof area does an 8 kW array of Trina Solar TSM-265PD05102 need?
An 8 kW DC system uses 31 Trina Solar TSM-265PD05102 modules (8,215 W STC / 7,539 W PTC), covering roughly 540 sq ft and saving ~$2,055/yr at 18.54 c/kWh.
How does Trina Solar TSM-265PD05102 compare against Centrosolar America CP60 265-C1?
Trina Solar TSM-265PD05102 outputs 265.0 W STC (38.3 V Voc, rank #18,880 of 21,677), while Centrosolar America CP60 265-C1 delivers 265.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)