Trina Solar TSM-250PA0515 is a 250.0 W STC (227.4 W PTC) Multi-c-Si solar module ranking #19,686 of 21,677 CEC listings (below all-CEC median; higher than 8.0% of peers). It delivers 15.45% efficiency, 37.4 V Voc at 25 C, and 41.72 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 250.0 W
- PTC Wattage
- 227.4 W
- Voc @ 25C
- 37.4 V
- Efficiency
- 15.45%
How Does Trina Solar TSM-250PA0515 Compare Against Peer CEC Listings?
How Trina Solar Trina Solar TSM-250PA0515 handles rooftop heat (227.4 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Trina Solar TSM-250PA0515 exhibits 8.55 A short-circuit current, requiring a 13.34 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,686 of 21,677 (28.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 51.8 m2 for an 8 kW system (40 panels for 10 kW). Lower 37.4 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Trina Solar TSM-250PA0515 Fall Across Listed CEC Models?
Where Trina Solar TSM-250PA0515 (250.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Trina Solar TSM-250PA0515?
Percentile placement of Trina Solar TSM-250PA0515 across power density (154.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Trina Solar TSM-250PA0515?
Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-250PA0515 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
250.0 W STC · Higher Than 8.0%
250.0 W STC (-135.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.45% Aperture Efficiency
Power density 154.5 W/m2 (4.46 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.72 V at -10 C (584.1 V string) and 42.95 V at -20 C (13 max).
32 Panels = 8,000 W STC
Occupies 51.8 m2 (557 sq ft) producing 7,277 W PTC; NEC 690.8 OCPD floor is 13.34 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.4 * (1 + (-0.33/100) * (-10 - 25)) = 41.72 V | OCPD = 1.56 * 8.55 = 13.34 A
Inputs from CEC Modules.csv for Trina Solar TSM-250PA0515: Voc=37.4 V, beta_Voc=-0.33%/C, Isc=8.55 A, STC=250.0 W, Area=1.618 m2.
Result: 14 panels max on 600 V (584.1 V); 32 panels for 8 kW (557 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-250PA0515?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-250PA0515.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 250.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 227.4 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.0 V / 8.06 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.45% (1.618 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-250PA0515 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-250PA0515 (250.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.0 kW | 418 sq ft | $1,502 | $2,539 |
| 8 kW Class | 32 | 8.0 kW | 557 sq ft | $2,002 | $3,386 |
| 10 kW Class | 40 | 10.0 kW | 697 sq ft | $2,503 | $4,232 |
How Many Trina Solar TSM-250PA0515 Modules Fit in a Cold-Weather String?
Maximum series module counts for Trina Solar TSM-250PA0515 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.95 V | 13 panels | 558.4 V | 23 panels |
| -10 C (14 F) | 41.72 V | 14 panels | 584.1 V | 23 panels |
| 0 C (32 F) | 40.49 V | 14 panels | 566.9 V | 24 panels |
| 25 C (77 F STC) | 37.4 V | 16 panels | 598.4 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-250PA0515?
Alternative CEC solar modules from competing brands near Trina Solar TSM-250PA0515 (250.0 W), including Anji Technology AJP-M660-250. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anji Technology AJP-M660-250 Anji Technology |
250.0 W | Tie (0 W) | 37.32 V | 15.4% | 89.0% |
| Boviet Solar Technology Co Ltd BVM6610P-250 Boviet Solar Technology Co Ltd |
250.0 W | Tie (0 W) | 37.5 V | 15.37% | 90.2% |
| Eoplly New Energy Technology EP156MB/60-250S AC Eoplly New Energy Technology |
250.0 W | Tie (0 W) | 37.26 V | 15.45% | 89.6% |
| Changzhou Nesl Solartech DJ-250DA/C-ST15 Changzhou Nesl Solartech |
250.0 W | Tie (0 W) | 38.07 V | 15.3% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-250PA0515?
Evaluate Trina Solar TSM-250PA0515 (250.0 W STC, 37.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-250PA0515 reaches 42.95 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 557 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (557 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-250PA0515 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-250PA0515 8 kW Residential Fit
Needs 32 modules (557 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Anji Technology AJP-M660-250.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 227.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-250PA0515 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Trina Solar TSM-250PA0515 PTC wattage (227.4 W) lower than STC (250.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 227.4 W PTC (91.0% retention) across Trina Solar TSM-250PA0515's 1.618 m2 aperture.
Who should skip Trina Solar TSM-250PA0515 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 32 Trina Solar TSM-250PA0515 panels (557 sq ft) leave unusable roof gaps vs. Anji Technology AJP-M660-250.
What is the 1,000 V commercial string limit for Trina Solar TSM-250PA0515?
On 1,000 V commercial inverters at -10 C (41.72 V cold Voc), Trina Solar TSM-250PA0515 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-250PA0515.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)