Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar CoLtd TSM-570NE19RC — CEC Solar Module Specifications

Manufacturer: Trina Solar CoLtd Registry: CEC Verified Engineering Specification

Trina Solar CoLtd TSM-570NE19RC is a 570.0 W STC (539.5 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 21.27% efficiency, 46.6 V Voc at 25 C, and 50.47 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
570.0 W
PTC Wattage
539.5 W
Voc @ 25C
46.6 V
Efficiency
21.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar CoLtd TSM-570NE19RC Compare Against Peer CEC Listings?

Solar engineering breakdown for Trina Solar CoLtd TSM-570NE19RC: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 570.0 W STC and 539.5 W PTC, Trina Solar CoLtd TSM-570NE19RC sits +185.0 W vs all-CEC median (top 10.5%; higher than 89.5% of peers) among 21,677 listed modules. Power density reaches 212.7 W/m2 (1.36 percentage points above 19.91% CEC median). Mid-range 46.6 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Gautam Solar Pvt Ltd G2G1710-HAD rates 570.0 W.

Where Does Trina Solar CoLtd TSM-570NE19RC Fall Across Listed CEC Models?

Distribution marker showing Trina Solar CoLtd TSM-570NE19RC (570.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar CoLtd TSM-570NE19RC (570.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar CoLtd : 570.0 W

What Dataset Percentiles Define Trina Solar CoLtd TSM-570NE19RC?

Dataset percentiles tracking Trina Solar CoLtd TSM-570NE19RC power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Trina Solar CoLtd TSM-570NE19RC Engineering BenchmarksPercentile comparison of Trina Solar CoLtd TSM-570NE19RC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage570.0 WPTC/STC Retention94.6%Module Efficiency21.27%

What Do the Dataset Ranks Show for Trina Solar CoLtd TSM-570NE19RC?

Benchmark highlights for Trina Solar CoLtd TSM-570NE19RC covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #2,154 / 21,677

Top 10.5% STC Output

570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,344

21.27% Aperture Efficiency

Power density 212.7 W/m2 (1.36 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.47 V at -10 C (555.2 V string) and 51.57 V at -20 C (11 max).

8 kW Reference Array

15 Panels = 8,550 W STC

Occupies 40.2 m2 (433 sq ft) producing 8,092 W PTC; NEC 690.8 OCPD floor is 24.35 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.6 * (1 + (-0.237/100) * (-10 - 25)) = 50.47 V | OCPD = 1.56 * 15.61 = 24.35 A

Inputs from CEC Modules.csv for Trina Solar CoLtd TSM-570NE19RC: Voc=46.6 V, beta_Voc=-0.237%/C, Isc=15.61 A, STC=570.0 W, Area=2.68 m2.

Result: 11 panels max on 600 V (555.2 V); 15 panels for 8 kW (433 sq ft).

What Are the Published CEC Specifications for Trina Solar CoLtd TSM-570NE19RC?

Official CEC datasheet figures for Trina Solar CoLtd TSM-570NE19RC (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar CoLtd TSM-570NE19RC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 570.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 539.5 W (94.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 15.61 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.6 V / 14.75 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.237 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.27% (2.68 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many Trina Solar CoLtd TSM-570NE19RC Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Trina Solar CoLtd TSM-570NE19RC modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.27 kW 317 sq ft $1,569 $2,654
8 kW Class 15 8.55 kW 433 sq ft $2,140 $3,619
10 kW Class 18 10.26 kW 519 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Trina Solar CoLtd Series?

Consolidated Trina Solar CoLtd wattage variants sharing the Trina Solar CoLtd TSM-570NE19RC mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Trina Solar CoLtd TSM-570NE19RC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar CoLtd TSM-565NE19RC 565.0 W 534.7 W 46.3 V 38.4 V 21.08%
Trina Solar CoLtd TSM-570NE19RC 570.0 W 539.5 W 46.6 V 38.6 V 21.27%

How Many Trina Solar CoLtd TSM-570NE19RC Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar CoLtd TSM-570NE19RC (50.47 V at 14 F).

Computed from Voc=46.6V and beta_Voc=-0.237%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.57 V 11 panels 567.3 V 19 panels
-10 C (14 F) 50.47 V 11 panels 555.2 V 19 panels
0 C (32 F) 49.36 V 12 panels 592.3 V 20 panels
25 C (77 F STC) 46.6 V 12 panels 559.2 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar CoLtd TSM-570NE19RC?

Competing CEC solar panels closest to Trina Solar CoLtd TSM-570NE19RC in nameplate wattage and Voc, starting with Gautam Solar Pvt Ltd G2G1710-HAD.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gautam Solar Pvt Ltd G2G1710-HAD
Gautam Solar Pvt Ltd
570.0 W Tie (0 W) 50.74 V 22.2% 95.1%
Gautam Solar Pvt Ltd G2X1710N-UHAD
Gautam Solar Pvt Ltd
570.0 W Tie (0 W) 50.74 V 22.18% 94.9%
BLUESUN GROUP LIMITED BSM565M10-72HBD
BLUESUN GROUP LIMITED
565.0 W -5.0 W 49.84 V 21.9% 94.5%
CSI Solar Co Ltd CS6W-570TB-AG
CSI Solar Co Ltd
570.0 W Tie (0 W) 51.8 V 22.71% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar CoLtd TSM-570NE19RC?

Evaluate Trina Solar CoLtd TSM-570NE19RC (570.0 W STC, 46.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar CoLtd TSM-570NE19RC reaches 51.57 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 433 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Trina Solar CoLtd TSM-570NE19RC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar CoLtd TSM-570NE19RC 8 kW Residential Fit

Needs 15 modules (433 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Gautam Solar Pvt Ltd G2G1710-HAD.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 539.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar CoLtd TSM-570NE19RC by Trina Solar CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar CoLtd TSM-570NE19RC panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar CoLtd TSM-570NE19RC cold Voc rises from 46.6 V to 50.47 V (beta_Voc -0.237%/C), capping a 600 V string at 11 panels (555.2 V).

How much roof area does an 8 kW array of Trina Solar CoLtd TSM-570NE19RC need?

An 8 kW DC system uses 15 Trina Solar CoLtd TSM-570NE19RC modules (8,550 W STC / 8,092 W PTC), covering roughly 433 sq ft and saving ~$2,140/yr at 18.54 c/kWh.

How does Trina Solar CoLtd TSM-570NE19RC compare against Gautam Solar Pvt Ltd G2G1710-HAD?

Trina Solar CoLtd TSM-570NE19RC outputs 570.0 W STC (46.6 V Voc, rank #2,154 of 21,677), while Gautam Solar Pvt Ltd G2G1710-HAD delivers 570.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.