Topsun Co Ltd TSH-S460SB2BK(X)5 is a 460.0 W STC (404.3 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 17.62% efficiency, 63.41 V Voc at 25 C, and 67.54 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 460.0 W
- PTC Wattage
- 404.3 W
- Voc @ 25C
- 63.41 V
- Efficiency
- 17.62%
How Does Topsun Co Ltd TSH-S460SB2BK(X)5 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Topsun Co Ltd TSH-S460SB2BK(X)5 (Mono-c-Si) residential solar systems.
Homeowners evaluating Topsun Co Ltd TSH-S460SB2BK(X)5 need 14 panels for 6 kW or 18 panels (506 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (506 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.186%/C) pushes open-circuit voltage to 67.54 V at 14 F and 68.72 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Topsun Co Ltd TSH-S460SB2BK(X)5 Fall Across Listed CEC Models?
Comparison of Topsun Co Ltd TSH-S460SB2BK(X)5 (460.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Topsun Co Ltd TSH-S460SB2BK(X)5?
Relative ranking of Topsun Co Ltd TSH-S460SB2BK(X)5 across nameplate watts, 87.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Topsun Co Ltd TSH-S460SB2BK(X)5?
Summary of Topsun Co Ltd TSH-S460SB2BK(X)5 output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 25.0% STC Output
460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.62% Aperture Efficiency
Power density 176.2 W/m2 (2.29 percentage points below 19.91% CEC median). PTC/STC ratio: 87.9% (rank #21,435).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 67.54 V at -10 C (540.3 V string) and 68.72 V at -20 C (8 max).
18 Panels = 8,280 W STC
Occupies 47.0 m2 (506 sq ft) producing 7,277 W PTC; NEC 690.8 OCPD floor is 14.31 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 63.41 * (1 + (-0.186/100) * (-10 - 25)) = 67.54 V | OCPD = 1.56 * 9.17 = 14.31 A
Inputs from CEC Modules.csv for Topsun Co Ltd TSH-S460SB2BK(X)5: Voc=63.41 V, beta_Voc=-0.186%/C, Isc=9.17 A, STC=460.0 W, Area=2.61 m2.
Result: 8 panels max on 600 V (540.3 V); 18 panels for 8 kW (506 sq ft).
What Are the Published CEC Specifications for Topsun Co Ltd TSH-S460SB2BK(X)5?
Complete CEC test sheet for Topsun Co Ltd TSH-S460SB2BK(X)5 including Isc (9.17 A), Voc (63.41 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 404.3 W (87.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 63.41 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.17 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 52.75 V / 8.72 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.186 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.62% (2.61 m2) | Array roof footprint density |
| Cell Count & Technology | 50 cells (Mono-c-Si) | Monofacial backsheet |
How Many Topsun Co Ltd TSH-S460SB2BK(X)5 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Topsun Co Ltd TSH-S460SB2BK(X)5.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.44 kW | 393 sq ft | $1,612 | $2,726 |
| 8 kW Class | 18 | 8.28 kW | 506 sq ft | $2,072 | $3,504 |
| 10 kW Class | 22 | 10.12 kW | 618 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Topsun Co Ltd Series?
Related Topsun Co Ltd power steps and black/silver trims consolidated into this Topsun Co Ltd TSH-S460SB2BK(X)5 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Topsun Co Ltd TSH-S450SB2BK(X)5 | 450.0 W | 395.2 W | 63.16 V | 52.54 V | 17.24% |
| Topsun Co Ltd TSH-S455SB2BK(X)5 | 455.0 W | 399.7 W | 63.29 V | 52.65 V | 17.43% |
| Topsun Co Ltd TSH-S460SB2BK(X)5 | 460.0 W | 404.3 W | 63.41 V | 52.75 V | 17.62% |
| Topsun Co Ltd TSH-S465SB2BK(X)5 | 465.0 W | 408.9 W | 63.52 V | 52.84 V | 17.82% |
| Topsun Co Ltd TSH-S470SB2BK(X)5 | 470.0 W | 413.5 W | 63.65 V | 52.95 V | 18.01% |
How Many Topsun Co Ltd TSH-S460SB2BK(X)5 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Topsun Co Ltd TSH-S460SB2BK(X)5 (63.41 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 68.72 V | 8 panels | 549.8 V | 14 panels |
| -10 C (14 F) | 67.54 V | 8 panels | 540.3 V | 14 panels |
| 0 C (32 F) | 66.36 V | 9 panels | 597.2 V | 15 panels |
| 25 C (77 F STC) | 63.41 V | 9 panels | 570.7 V | 15 panels |
Which Cross-Brand Solar Modules Compare Closest to Topsun Co Ltd TSH-S460SB2BK(X)5?
Four comparable CEC modules such as Heliene 96M460 (460.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 96M460 Heliene |
460.0 W | Tie (0 W) | 61.79 V | 18.25% | 90.4% |
| Heliene 96M475 Heliene |
475.0 W | +15.0 W | 62.39 V | 18.85% | 90.5% |
| CSI Solar Co Ltd CS3Y-460P CSI Solar Co Ltd |
460.0 W | Tie (0 W) | 52.0 V | 20.09% | 93.1% |
| Heliene 144HC-460 Heliene |
460.0 W | Tie (0 W) | 51.26 V | 20.81% | 92.4% |
What Are the Design Limits and Best-Fit Uses for Topsun Co Ltd TSH-S460SB2BK(X)5?
Evaluate Topsun Co Ltd TSH-S460SB2BK(X)5 (460.0 W STC, 63.41 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Topsun Co Ltd TSH-S460SB2BK(X)5 reaches 68.72 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 506 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (506 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Topsun Co Ltd TSH-S460SB2BK(X)5 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Topsun Co Ltd TSH-S460SB2BK(X)5 8 kW Residential Fit
Needs 18 modules (506 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Heliene 96M460.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 404.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Topsun Co Ltd TSH-S460SB2BK(X)5 by Topsun Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Topsun Co Ltd TSH-S460SB2BK(X)5 PTC wattage (404.3 W) lower than STC (460.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 404.3 W PTC (87.9% retention) across Topsun Co Ltd TSH-S460SB2BK(X)5's 2.61 m2 aperture.
Who should skip Topsun Co Ltd TSH-S460SB2BK(X)5 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Topsun Co Ltd TSH-S460SB2BK(X)5 panels (506 sq ft) leave unusable roof gaps vs. Heliene 96M460.
What is the 1,000 V commercial string limit for Topsun Co Ltd TSH-S460SB2BK(X)5?
On 1,000 V commercial inverters at -10 C (67.54 V cold Voc), Topsun Co Ltd TSH-S460SB2BK(X)5 fits up to 14 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)