Skip to main content
WireAndSun
Calculators
CEC PV Module

Topsun Co Ltd TOP CLASS 540DE13 — CEC Solar Module Specifications

Manufacturer: Topsun Co Ltd Registry: CEC Verified Engineering Specification

Topsun Co Ltd TOP CLASS 540DE13 is a 540.0 W STC (506.9 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.09% efficiency, 49.51 V Voc at 25 C, and 54.07 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
506.9 W
Voc @ 25C
49.51 V
Efficiency
21.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Topsun Co Ltd TOP CLASS 540DE13 Compare Against Peer CEC Listings?

Solar engineering breakdown for Topsun Co Ltd TOP CLASS 540DE13: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Topsun Co Ltd and peers, Topsun Co Ltd TOP CLASS 540DE13 stands 130.0 W above the 410.0 W Mono-c-Si median and strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,622-$2,568/yr in baseline US bill offset. Higher 49.51 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Topsun Co Ltd TOP CLASS 540DE13 Fall Across Listed CEC Models?

Distribution marker showing Topsun Co Ltd TOP CLASS 540DE13 (540.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Topsun Co Ltd TOP CLASS 540DE13 (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTopsun Co Ltd TOP : 540.0 W

What Dataset Percentiles Define Topsun Co Ltd TOP CLASS 540DE13?

Dataset percentiles tracking Topsun Co Ltd TOP CLASS 540DE13 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Topsun Co Ltd TOP CLASS 540DE13 Engineering BenchmarksPercentile comparison of Topsun Co Ltd TOP CLASS 540DE13 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention93.9%Module Efficiency21.09%

What Do the Dataset Ranks Show for Topsun Co Ltd TOP CLASS 540DE13?

Benchmark highlights for Topsun Co Ltd TOP CLASS 540DE13 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,965

21.09% Aperture Efficiency

Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.07 V at -10 C (594.8 V string) and 55.37 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,604 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.51 * (1 + (-0.263/100) * (-10 - 25)) = 54.07 V | OCPD = 1.56 * 13.85 = 21.61 A

Inputs from CEC Modules.csv for Topsun Co Ltd TOP CLASS 540DE13: Voc=49.51 V, beta_Voc=-0.263%/C, Isc=13.85 A, STC=540.0 W, Area=2.56 m2.

Result: 11 panels max on 600 V (594.8 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for Topsun Co Ltd TOP CLASS 540DE13?

Official CEC datasheet figures for Topsun Co Ltd TOP CLASS 540DE13 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Topsun Co Ltd TOP CLASS 540DE13.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 506.9 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.51 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.32 V / 13.07 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.09% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Topsun Co Ltd TOP CLASS 540DE13 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Topsun Co Ltd TOP CLASS 540DE13 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 331 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 413 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 524 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Topsun Co Ltd Series?

Consolidated Topsun Co Ltd wattage variants sharing the Topsun Co Ltd TOP CLASS 540DE13 mechanical and cell layout.

Sibling CEC listings grouped into the Topsun Co Ltd TOP CLASS 540DE13 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Topsun Co Ltd TOP CLASS 530DE13 530.0 W 497.3 W 49.25 V 41.06 V 20.7%
Topsun Co Ltd TOP CLASS 535DE13 535.0 W 502.1 W 49.38 V 41.18 V 20.9%
Topsun Co Ltd TOP CLASS 540DE13 540.0 W 506.9 W 49.51 V 41.32 V 21.09%
Topsun Co Ltd TOP CLASS 545DE13 545.0 W 511.7 W 49.64 V 41.46 V 21.29%

How Many Topsun Co Ltd TOP CLASS 540DE13 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Topsun Co Ltd TOP CLASS 540DE13 (54.07 V at 14 F).

Computed from Voc=49.51V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.37 V 10 panels 553.7 V 18 panels
-10 C (14 F) 54.07 V 11 panels 594.8 V 18 panels
0 C (32 F) 52.77 V 11 panels 580.5 V 18 panels
25 C (77 F STC) 49.51 V 12 panels 594.1 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Topsun Co Ltd TOP CLASS 540DE13?

Competing CEC solar panels closest to Topsun Co Ltd TOP CLASS 540DE13 in nameplate wattage and Voc, starting with Dehui Solar Power (Vietnam) CoLtd DH-M172B 540W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Dehui Solar Power (Vietnam) CoLtd DH-M172B 540W
Dehui Solar Power (Vietnam) CoLtd
540.0 W Tie (0 W) 49.51 V 21.09% 93.4%
Dehui Solar Power (Vietnam) CoLtd DH-M172W 540W
Dehui Solar Power (Vietnam) CoLtd
540.0 W Tie (0 W) 49.51 V 21.09% 93.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
540.0 W Tie (0 W) 49.5 V 21.09% 93.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144E
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
540.0 W Tie (0 W) 49.5 V 21.09% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Topsun Co Ltd TOP CLASS 540DE13?

Evaluate Topsun Co Ltd TOP CLASS 540DE13 (540.0 W STC, 49.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Topsun Co Ltd TOP CLASS 540DE13 reaches 55.37 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Topsun Co Ltd TOP CLASS 540DE13 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Topsun Co Ltd TOP CLASS 540DE13 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M172B 540W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 506.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Topsun Co Ltd TOP CLASS 540DE13 by Topsun Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Topsun Co Ltd TOP CLASS 540DE13?

Multiplying Topsun Co Ltd TOP CLASS 540DE13's 13.85 A short-circuit current by 1.56 equals 21.61 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Topsun Co Ltd TOP CLASS 540DE13 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.07 V cold Voc at 14 F and handles 13.85 A Isc; string inverters cap Topsun Co Ltd TOP CLASS 540DE13 at 11 panels on 600 V.

Is Topsun Co Ltd TOP CLASS 540DE13 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Topsun Co Ltd TOP CLASS 540DE13 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.