Topsun Co Ltd TOP CLASS 395DE13 is a 395.0 W STC (365.6 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.47% efficiency, 36.94 V Voc at 25 C, and 40.37 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 365.6 W
- Voc @ 25C
- 36.94 V
- Efficiency
- 20.47%
How Does Topsun Co Ltd TOP CLASS 395DE13 Compare Against Peer CEC Listings?
Solar engineering breakdown for Topsun Co Ltd TOP CLASS 395DE13: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Topsun Co Ltd and peers, Topsun Co Ltd TOP CLASS 395DE13 stands 15.0 W below the 410.0 W Mono-c-Si median and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,582-$2,570/yr in baseline US bill offset. Lower 36.94 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Topsun Co Ltd TOP CLASS 395DE13 Fall Across Listed CEC Models?
Distribution marker showing Topsun Co Ltd TOP CLASS 395DE13 (395.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Topsun Co Ltd TOP CLASS 395DE13?
Dataset percentiles tracking Topsun Co Ltd TOP CLASS 395DE13 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Topsun Co Ltd TOP CLASS 395DE13?
Benchmark highlights for Topsun Co Ltd TOP CLASS 395DE13 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.47% Aperture Efficiency
Power density 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.37 V at -10 C (565.2 V string) and 41.35 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.5 m2 (436 sq ft) producing 7,678 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.94 * (1 + (-0.265/100) * (-10 - 25)) = 40.37 V | OCPD = 1.56 * 13.71 = 21.39 A
Inputs from CEC Modules.csv for Topsun Co Ltd TOP CLASS 395DE13: Voc=36.94 V, beta_Voc=-0.265%/C, Isc=13.71 A, STC=395.0 W, Area=1.93 m2.
Result: 14 panels max on 600 V (565.2 V); 21 panels for 8 kW (436 sq ft).
What Are the Published CEC Specifications for Topsun Co Ltd TOP CLASS 395DE13?
Official CEC datasheet figures for Topsun Co Ltd TOP CLASS 395DE13 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 365.6 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.94 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.57 V / 12.92 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.265 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.47% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Topsun Co Ltd TOP CLASS 395DE13 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Topsun Co Ltd TOP CLASS 395DE13 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 332 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 436 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 540 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This Topsun Co Ltd Series?
Consolidated Topsun Co Ltd wattage variants sharing the Topsun Co Ltd TOP CLASS 395DE13 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Topsun Co Ltd TOP CLASS 390DE13 | 390.0 W | 360.9 W | 36.81 V | 30.4 V | 20.21% |
| Topsun Co Ltd TOP CLASS 395DE13 | 395.0 W | 365.6 W | 36.94 V | 30.57 V | 20.47% |
How Many Topsun Co Ltd TOP CLASS 395DE13 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Topsun Co Ltd TOP CLASS 395DE13 (40.37 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.35 V | 14 panels | 578.9 V | 24 panels |
| -10 C (14 F) | 40.37 V | 14 panels | 565.2 V | 24 panels |
| 0 C (32 F) | 39.39 V | 15 panels | 590.9 V | 25 panels |
| 25 C (77 F STC) | 36.94 V | 16 panels | 591.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Topsun Co Ltd TOP CLASS 395DE13?
Competing CEC solar panels closest to Topsun Co Ltd TOP CLASS 395DE13 in nameplate wattage and Voc, starting with ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
395.0 W | Tie (0 W) | 36.94 V | 20.47% | 92.6% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154W 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 36.94 V | 20.47% | 92.6% |
| Aptos Solar Technology LLC DNA-108-MF10-395W Aptos Solar Technology LLC |
395.0 W | Tie (0 W) | 36.98 V | 20.26% | 93.7% |
| BYD Company Limited BYD395MLK-27 BYD Company Limited |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.6% |
What Are the Design Limits and Best-Fit Uses for Topsun Co Ltd TOP CLASS 395DE13?
Evaluate Topsun Co Ltd TOP CLASS 395DE13 (395.0 W STC, 36.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Topsun Co Ltd TOP CLASS 395DE13 reaches 41.35 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 436 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (436 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Topsun Co Ltd TOP CLASS 395DE13 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Topsun Co Ltd TOP CLASS 395DE13 8 kW Residential Fit
Needs 21 modules (436 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Topsun Co Ltd TOP CLASS 395DE13 by Topsun Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Topsun Co Ltd TOP CLASS 395DE13?
Multiplying Topsun Co Ltd TOP CLASS 395DE13's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Topsun Co Ltd TOP CLASS 395DE13 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.37 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap Topsun Co Ltd TOP CLASS 395DE13 at 14 panels on 600 V.
Is Topsun Co Ltd TOP CLASS 395DE13 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Topsun Co Ltd TOP CLASS 395DE13 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)