Skip to main content
WireAndSun
Calculators
CEC PV Module

TOPCO SOLAR INC TP120H-440MB — CEC Solar Module Specifications

Manufacturer: TOPCO SOLAR INC Registry: CEC Verified Engineering Specification

TOPCO SOLAR INC TP120H-440MB is a 440.0 W STC (412.3 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.37% efficiency, 41.02 V Voc at 25 C, and 44.93 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
412.3 W
Voc @ 25C
41.02 V
Efficiency
20.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does TOPCO SOLAR INC TP120H-440MB Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for TOPCO SOLAR INC TP120H-440MB (Mono-c-Si) residential solar systems.

Homeowners evaluating TOPCO SOLAR INC TP120H-440MB need 14 panels for 6 kW or 19 panels (442 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.272%/C) pushes open-circuit voltage to 44.93 V at 14 F and 46.04 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does TOPCO SOLAR INC TP120H-440MB Fall Across Listed CEC Models?

Comparison of TOPCO SOLAR INC TP120H-440MB (440.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where TOPCO SOLAR INC TP120H-440MB (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTOPCO SOLAR INC TP: 440.0 W

What Dataset Percentiles Define TOPCO SOLAR INC TP120H-440MB?

Relative ranking of TOPCO SOLAR INC TP120H-440MB across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency.

TOPCO SOLAR INC TP120H-440MB Engineering BenchmarksPercentile comparison of TOPCO SOLAR INC TP120H-440MB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention93.7%Module Efficiency20.37%

What Do the Dataset Ranks Show for TOPCO SOLAR INC TP120H-440MB?

Summary of TOPCO SOLAR INC TP120H-440MB output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,017

20.37% Aperture Efficiency

Power density 203.7 W/m2 (0.46 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.93 V at -10 C (584.1 V string) and 46.04 V at -20 C (13 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 41.0 m2 (442 sq ft) producing 7,834 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.02 * (1 + (-0.272/100) * (-10 - 25)) = 44.93 V | OCPD = 1.56 * 13.73 = 21.42 A

Inputs from CEC Modules.csv for TOPCO SOLAR INC TP120H-440MB: Voc=41.02 V, beta_Voc=-0.272%/C, Isc=13.73 A, STC=440.0 W, Area=2.16 m2.

Result: 13 panels max on 600 V (584.1 V); 19 panels for 8 kW (442 sq ft).

What Are the Published CEC Specifications for TOPCO SOLAR INC TP120H-440MB?

Complete CEC test sheet for TOPCO SOLAR INC TP120H-440MB including Isc (13.73 A), Voc (41.02 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for TOPCO SOLAR INC TP120H-440MB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 412.3 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.02 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.72 V / 13.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.37% (2.16 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many TOPCO SOLAR INC TP120H-440MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using TOPCO SOLAR INC TP120H-440MB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 326 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 442 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 535 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This TOPCO SOLAR INC Series?

Related TOPCO SOLAR INC power steps and black/silver trims consolidated into this TOPCO SOLAR INC TP120H-440MB series guide.

Sibling CEC listings grouped into the TOPCO SOLAR INC TP120H-440MB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
TOPCO SOLAR INC TP120H-435MB 435.0 W 407.5 W 40.95 V 33.63 V 20.14%
TOPCO SOLAR INC TP120H-440MB 440.0 W 412.3 W 41.02 V 33.72 V 20.37%
TOPCO SOLAR INC TP120H-445MB 445.0 W 417.2 W 41.1 V 33.82 V 20.6%

How Many TOPCO SOLAR INC TP120H-440MB Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for TOPCO SOLAR INC TP120H-440MB (41.02 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.02V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.04 V 13 panels 598.5 V 21 panels
-10 C (14 F) 44.93 V 13 panels 584.1 V 22 panels
0 C (32 F) 43.81 V 13 panels 569.5 V 22 panels
25 C (77 F STC) 41.02 V 14 panels 574.3 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to TOPCO SOLAR INC TP120H-440MB?

Four comparable CEC modules such as CertainTeed CTM10440HC11-06 (440.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10440HC11-06
CertainTeed
440.0 W Tie (0 W) 41.02 V 20.37% 93.7%
Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
440.0 W Tie (0 W) 41.0 V 20.37% 93.7%
Elin Energy (Sirius PV) ELNSM60M-HC-440
Elin Energy (Sirius PV)
440.0 W Tie (0 W) 41.12 V 20.47% 94.2%
CertainTeed CTM10440HC11-09
CertainTeed
440.0 W Tie (0 W) 40.9 V 20.56% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for TOPCO SOLAR INC TP120H-440MB?

Evaluate TOPCO SOLAR INC TP120H-440MB (440.0 W STC, 41.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), TOPCO SOLAR INC TP120H-440MB reaches 46.04 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of TOPCO SOLAR INC TP120H-440MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

TOPCO SOLAR INC TP120H-440MB 8 kW Residential Fit

Needs 19 modules (442 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CTM10440HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for TOPCO SOLAR INC TP120H-440MB by TOPCO SOLAR INC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is TOPCO SOLAR INC TP120H-440MB PTC wattage (412.3 W) lower than STC (440.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.3 W PTC (93.7% retention) across TOPCO SOLAR INC TP120H-440MB's 2.16 m2 aperture.

Who should skip TOPCO SOLAR INC TP120H-440MB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 TOPCO SOLAR INC TP120H-440MB panels (442 sq ft) leave unusable roof gaps vs. CertainTeed CTM10440HC11-06.

What is the 1,000 V commercial string limit for TOPCO SOLAR INC TP120H-440MB?

On 1,000 V commercial inverters at -10 C (44.93 V cold Voc), TOPCO SOLAR INC TP120H-440MB fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting TOPCO SOLAR INC TP120H-440MB.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.