Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 is a 450.0 W STC (426.0 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 23.08% efficiency, 39.6 V Voc at 25 C, and 42.9 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 426.0 W
- Voc @ 25C
- 39.6 V
- Efficiency
- 23.08%
How Does Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 (Mono-c-Si) residential solar systems.
Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 delivers 230.8 W/m2 (3.17 percentage points above 19.91% CEC median) and strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (378 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 43.84 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with ES Foundry Corp ES-DN8-H54B-450 (450.0 W).
Where Does Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 Fall Across Listed CEC Models?
Comparison of Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 (450.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450?
Relative ranking of Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 across nameplate watts, 94.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450?
Summary of Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.08% Aperture Efficiency
Power density 230.8 W/m2 (3.17 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.9 V at -10 C (557.7 V string) and 43.84 V at -20 C (13 max).
18 Panels = 8,100 W STC
Occupies 35.1 m2 (378 sq ft) producing 7,668 W PTC; NEC 690.8 OCPD floor is 21.64 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.6 * (1 + (-0.238/100) * (-10 - 25)) = 42.9 V | OCPD = 1.56 * 13.87 = 21.64 A
Inputs from CEC Modules.csv for Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450: Voc=39.6 V, beta_Voc=-0.238%/C, Isc=13.87 A, STC=450.0 W, Area=1.95 m2.
Result: 13 panels max on 600 V (557.7 V); 18 panels for 8 kW (378 sq ft).
What Are the Published CEC Specifications for Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450?
Complete CEC test sheet for Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 including Isc (13.87 A), Voc (39.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 426.0 W (94.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.87 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.2 V / 13.56 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.238 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.08% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 294 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 378 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 483 sq ft | $2,591 | $4,380 |
How Many Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 (39.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.84 V | 13 panels | 569.9 V | 22 panels |
| -10 C (14 F) | 42.9 V | 13 panels | 557.7 V | 23 panels |
| 0 C (32 F) | 41.96 V | 14 panels | 587.4 V | 23 panels |
| 25 C (77 F STC) | 39.6 V | 15 panels | 594.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450?
Four comparable CEC modules such as ES Foundry Corp ES-DN8-H54B-450 (450.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ES Foundry Corp ES-DN8-H54B-450 ES Foundry Corp |
450.0 W | Tie (0 W) | 39.54 V | 23.11% | 95.2% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT450-108TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
450.0 W | Tie (0 W) | 39.53 V | 23.08% | 96.1% |
| AMPS Solar AMPS-450N-108BB AMPS Solar |
450.0 W | Tie (0 W) | 40.16 V | 23.2% | 95.2% |
| Aptos Solar Technology LLC DNA-108-BFN10-455W-DG Aptos Solar Technology LLC |
455.0 W | +5.0 W | 39.7 V | 23.45% | 95.1% |
What Are the Design Limits and Best-Fit Uses for Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450?
Evaluate Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 (450.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 reaches 43.84 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 378 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (378 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 8 kW Residential Fit
Needs 18 modules (378 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare ES Foundry Corp ES-DN8-H54B-450.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 426.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 by Suzhou Talesun Solar Technologies Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 panels fit on a 600 V winter solar string?
At -10 C (14 F), Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 cold Voc rises from 39.6 V to 42.9 V (beta_Voc -0.238%/C), capping a 600 V string at 13 panels (557.7 V).
How much roof area does an 8 kW array of Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 need?
An 8 kW DC system uses 18 Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 modules (8,100 W STC / 7,668 W PTC), covering roughly 378 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 compare against ES Foundry Corp ES-DN8-H54B-450?
Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450 outputs 450.0 W STC (39.6 V Voc, rank #5,679 of 21,677), while ES Foundry Corp ES-DN8-H54B-450 delivers 450.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)