Skip to main content
WireAndSun
Calculators
CEC PV Module

SunSpark Technology Inc SST6L60M(H)-375 — CEC Solar Module Specifications

Manufacturer: SunSpark Technology Inc Registry: CEC Verified Engineering Specification

SunSpark Technology Inc SST6L60M(H)-375 is a 375.0 W STC (348.3 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.6% efficiency, 41.3 V Voc at 25 C, and 45.55 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
375.0 W
PTC Wattage
348.3 W
Voc @ 25C
41.3 V
Efficiency
20.6%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunSpark Technology Inc SST6L60M(H)-375 Compare Against Peer CEC Listings?

Engineering position of SunSpark Technology Inc SST6L60M(H)-375 (375.0 W STC) vs. CSI Solar Co Ltd CS3L-375P across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, SunSpark Technology Inc SST6L60M(H)-375 pairs strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677) with 41.3 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,663 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3L-375P offers a 375.0 W alternative.

Where Does SunSpark Technology Inc SST6L60M(H)-375 Fall Across Listed CEC Models?

Plots SunSpark Technology Inc SST6L60M(H)-375 at 375.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunSpark Technology Inc SST6L60M(H)-375 (375.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunSpark Technolog: 375.0 W

What Dataset Percentiles Define SunSpark Technology Inc SST6L60M(H)-375?

Benchmarks SunSpark Technology Inc SST6L60M(H)-375 on STC wattage, thermal PTC/STC retention, and 20.6 aperture conversion efficiency against CEC peers.

SunSpark Technology Inc SST6L60M(H)-375 Engineering BenchmarksPercentile comparison of SunSpark Technology Inc SST6L60M(H)-375 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage375.0 WPTC/STC Retention92.9%Module Efficiency20.6%

What Do the Dataset Ranks Show for SunSpark Technology Inc SST6L60M(H)-375?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SunSpark Technology Inc SST6L60M(H)-375 by SunSpark Technology Inc.

Rank #11,367 / 21,677

375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,112

20.6% Aperture Efficiency

Power density 206.0 W/m2 (0.69 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.55 V at -10 C (592.1 V string) and 46.76 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,250 W STC

Occupies 40.0 m2 (431 sq ft) producing 7,663 W PTC; NEC 690.8 OCPD floor is 17.64 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.3 * (1 + (-0.294/100) * (-10 - 25)) = 45.55 V | OCPD = 1.56 * 11.31 = 17.64 A

Inputs from CEC Modules.csv for SunSpark Technology Inc SST6L60M(H)-375: Voc=41.3 V, beta_Voc=-0.294%/C, Isc=11.31 A, STC=375.0 W, Area=1.82 m2.

Result: 13 panels max on 600 V (592.1 V); 22 panels for 8 kW (431 sq ft).

What Are the Published CEC Specifications for SunSpark Technology Inc SST6L60M(H)-375?

Laboratory test ratings recorded for SunSpark Technology Inc SST6L60M(H)-375 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SunSpark Technology Inc SST6L60M(H)-375.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 375.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 348.3 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.2 V / 10.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.294 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.6% (1.82 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many SunSpark Technology Inc SST6L60M(H)-375 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (431 sq ft at 8 kW), and estimated Year-1 electric bill offset for SunSpark Technology Inc SST6L60M(H)-375.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.0 kW 313 sq ft $1,502 $2,539
8 kW Class 22 8.25 kW 431 sq ft $2,065 $3,492
10 kW Class 27 10.12 kW 529 sq ft $2,533 $4,283

How Many SunSpark Technology Inc SST6L60M(H)-375 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SunSpark Technology Inc SST6L60M(H)-375 (beta_Voc -0.294%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=41.3V and beta_Voc=-0.294%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.76 V 12 panels 561.1 V 21 panels
-10 C (14 F) 45.55 V 13 panels 592.1 V 21 panels
0 C (32 F) 44.34 V 13 panels 576.4 V 22 panels
25 C (77 F STC) 41.3 V 14 panels 578.2 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SST6L60M(H)-375?

Closest cross-brand CEC competitors to SunSpark Technology Inc SST6L60M(H)-375 matched near 375.0 W STC and 41.3 V Voc, led by CSI Solar Co Ltd CS3L-375P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-375P
CSI Solar Co Ltd
375.0 W Tie (0 W) 41.2 V 20.95% 92.5%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 21.07% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 20.72% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 20.49% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SST6L60M(H)-375?

Evaluate SunSpark Technology Inc SST6L60M(H)-375 (375.0 W STC, 41.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SST6L60M(H)-375 reaches 46.76 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
  • 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SST6L60M(H)-375 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunSpark Technology Inc SST6L60M(H)-375 8 kW Residential Fit

Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3L-375P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 348.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunSpark Technology Inc SST6L60M(H)-375 by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SunSpark Technology Inc SST6L60M(H)-375?

Multiplying SunSpark Technology Inc SST6L60M(H)-375's 11.31 A short-circuit current by 1.56 equals 17.64 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can SunSpark Technology Inc SST6L60M(H)-375 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.55 V cold Voc at 14 F and handles 11.31 A Isc; string inverters cap SunSpark Technology Inc SST6L60M(H)-375 at 13 panels on 600 V.

Is SunSpark Technology Inc SST6L60M(H)-375 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunSpark Technology Inc SST6L60M(H)-375 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.