Skip to main content
WireAndSun
Calculators
CEC PV Module

SunSpark Technology Inc SG7G72M(H)-555 — CEC Solar Module Specifications

Manufacturer: SunSpark Technology Inc Registry: CEC Verified Engineering Specification

SunSpark Technology Inc SG7G72M(H)-555 is a 555.0 W STC (515.6 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.43% efficiency, 50.1 V Voc at 25 C, and 55.43 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
555.0 W
PTC Wattage
515.6 W
Voc @ 25C
50.1 V
Efficiency
21.43%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunSpark Technology Inc SG7G72M(H)-555 Compare Against Peer CEC Listings?

Solar engineering breakdown for SunSpark Technology Inc SG7G72M(H)-555: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 555.0 W STC and 515.6 W PTC, SunSpark Technology Inc SG7G72M(H)-555 sits +170.0 W vs all-CEC median (top 12.6%; higher than 87.4% of peers) among 21,677 listed modules. Power density reaches 214.3 W/m2 (1.52 percentage points above 19.91% CEC median). Higher 50.1 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer G-Star Pte Ltd GSP7G72M(H)555WT rates 555.0 W.

Where Does SunSpark Technology Inc SG7G72M(H)-555 Fall Across Listed CEC Models?

Distribution marker showing SunSpark Technology Inc SG7G72M(H)-555 (555.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunSpark Technology Inc SG7G72M(H)-555 (555.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunSpark Technolog: 555.0 W

What Dataset Percentiles Define SunSpark Technology Inc SG7G72M(H)-555?

Dataset percentiles tracking SunSpark Technology Inc SG7G72M(H)-555 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

SunSpark Technology Inc SG7G72M(H)-555 Engineering BenchmarksPercentile comparison of SunSpark Technology Inc SG7G72M(H)-555 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage555.0 WPTC/STC Retention92.9%Module Efficiency21.43%

What Do the Dataset Ranks Show for SunSpark Technology Inc SG7G72M(H)-555?

Benchmark highlights for SunSpark Technology Inc SG7G72M(H)-555 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #2,550 / 21,677

Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,675

21.43% Aperture Efficiency

Power density 214.3 W/m2 (1.52 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.43 V at -10 C (554.3 V string) and 56.95 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,325 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,734 W PTC; NEC 690.8 OCPD floor is 21.95 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.1 * (1 + (-0.304/100) * (-10 - 25)) = 55.43 V | OCPD = 1.56 * 14.07 = 21.95 A

Inputs from CEC Modules.csv for SunSpark Technology Inc SG7G72M(H)-555: Voc=50.1 V, beta_Voc=-0.304%/C, Isc=14.07 A, STC=555.0 W, Area=2.59 m2.

Result: 10 panels max on 600 V (554.3 V); 15 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for SunSpark Technology Inc SG7G72M(H)-555?

Official CEC datasheet figures for SunSpark Technology Inc SG7G72M(H)-555 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for SunSpark Technology Inc SG7G72M(H)-555.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 555.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 515.6 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.07 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.1 V / 13.18 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.304 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.43% (2.59 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many SunSpark Technology Inc SG7G72M(H)-555 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many SunSpark Technology Inc SG7G72M(H)-555 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.11 kW 307 sq ft $1,529 $2,586
8 kW Class 15 8.32 kW 418 sq ft $2,082 $3,521
10 kW Class 19 10.54 kW 530 sq ft $2,638 $4,461

Which Sibling Wattage & Trim Variants Belong to This SunSpark Technology Inc Series?

Consolidated SunSpark Technology Inc wattage variants sharing the SunSpark Technology Inc SG7G72M(H)-555 mechanical and cell layout.

Sibling CEC listings grouped into the SunSpark Technology Inc SG7G72M(H)-555 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunSpark Technology Inc SG7G72M(H)-550 550.0 W 510.8 W 49.9 V 42.0 V 21.24%
SunSpark Technology Inc SG7G72M(H)-555 555.0 W 515.6 W 50.1 V 42.1 V 21.43%

How Many SunSpark Technology Inc SG7G72M(H)-555 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on SunSpark Technology Inc SG7G72M(H)-555 (55.43 V at 14 F).

Computed from Voc=50.1V and beta_Voc=-0.304%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.95 V 10 panels 569.5 V 17 panels
-10 C (14 F) 55.43 V 10 panels 554.3 V 18 panels
0 C (32 F) 53.91 V 11 panels 593.0 V 18 panels
25 C (77 F STC) 50.1 V 11 panels 551.1 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SG7G72M(H)-555?

Competing CEC solar panels closest to SunSpark Technology Inc SG7G72M(H)-555 in nameplate wattage and Voc, starting with G-Star Pte Ltd GSP7G72M(H)555WT.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
G-Star Pte Ltd GSP7G72M(H)555WT
G-Star Pte Ltd
555.0 W Tie (0 W) 50.08 V 21.68% 94.1%
GCL System Integration Technology Co Ltd GCL-M10/72GDF555
GCL System Integration Technology Co Ltd
555.0 W Tie (0 W) 50.08 V 21.68% 93.5%
AXITEC AC-555MBT/144V
AXITEC
555.0 W Tie (0 W) 50.05 V 21.68% 93.6%
AXITEC AC-555MBT/144VB
AXITEC
555.0 W Tie (0 W) 50.05 V 21.68% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SG7G72M(H)-555?

Evaluate SunSpark Technology Inc SG7G72M(H)-555 (555.0 W STC, 50.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SG7G72M(H)-555 reaches 56.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 418 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SG7G72M(H)-555 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunSpark Technology Inc SG7G72M(H)-555 8 kW Residential Fit

Needs 15 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare G-Star Pte Ltd GSP7G72M(H)555WT.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 515.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunSpark Technology Inc SG7G72M(H)-555 by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many SunSpark Technology Inc SG7G72M(H)-555 panels fit on a 600 V winter solar string?

At -10 C (14 F), SunSpark Technology Inc SG7G72M(H)-555 cold Voc rises from 50.1 V to 55.43 V (beta_Voc -0.304%/C), capping a 600 V string at 10 panels (554.3 V).

How much roof area does an 8 kW array of SunSpark Technology Inc SG7G72M(H)-555 need?

An 8 kW DC system uses 15 SunSpark Technology Inc SG7G72M(H)-555 modules (8,325 W STC / 7,734 W PTC), covering roughly 418 sq ft and saving ~$2,082/yr at 18.54 c/kWh.

How does SunSpark Technology Inc SG7G72M(H)-555 compare against G-Star Pte Ltd GSP7G72M(H)555WT?

SunSpark Technology Inc SG7G72M(H)-555 outputs 555.0 W STC (50.1 V Voc, rank #2,550 of 21,677), while G-Star Pte Ltd GSP7G72M(H)555WT delivers 555.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.