SunSpark Technology Inc SST-400M3-72 is a 400.0 W STC (373.1 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.3% efficiency, 49.86 V Voc at 25 C, and 53.91 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 373.1 W
- Voc @ 25C
- 49.86 V
- Efficiency
- 20.3%
How Does SunSpark Technology Inc SST-400M3-72 Compare Against Peer CEC Listings?
How SunSpark Technology Inc SunSpark Technology Inc SST-400M3-72 handles rooftop heat (373.1 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, SunSpark Technology Inc SST-400M3-72 exhibits 10.29 A short-circuit current, requiring a 16.05 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #9,407 of 21,677 (10.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.4 m2 for an 8 kW system (25 panels for 10 kW). Higher 49.86 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does SunSpark Technology Inc SST-400M3-72 Fall Across Listed CEC Models?
Where SunSpark Technology Inc SST-400M3-72 (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SunSpark Technology Inc SST-400M3-72?
Percentile placement of SunSpark Technology Inc SST-400M3-72 across power density (203.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for SunSpark Technology Inc SST-400M3-72?
Four critical engineering numbers homeowners and solar installers check first when reviewing SunSpark Technology Inc SST-400M3-72 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.3% Aperture Efficiency
Power density 203.0 W/m2 (0.39 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.91 V at -10 C (593.0 V string) and 55.07 V at -20 C (10 max).
20 Panels = 8,000 W STC
Occupies 39.4 m2 (424 sq ft) producing 7,462 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.86 * (1 + (-0.232/100) * (-10 - 25)) = 53.91 V | OCPD = 1.56 * 10.29 = 16.05 A
Inputs from CEC Modules.csv for SunSpark Technology Inc SST-400M3-72: Voc=49.86 V, beta_Voc=-0.232%/C, Isc=10.29 A, STC=400.0 W, Area=1.97 m2.
Result: 11 panels max on 600 V (593.0 V); 20 panels for 8 kW (424 sq ft).
What Are the Published CEC Specifications for SunSpark Technology Inc SST-400M3-72?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunSpark Technology Inc SST-400M3-72.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 373.1 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.86 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.29 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.18 V / 9.73 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.232 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.3% (1.97 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many SunSpark Technology Inc SST-400M3-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunSpark Technology Inc SST-400M3-72 (400.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 318 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 424 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 530 sq ft | $2,503 | $4,232 |
How Many SunSpark Technology Inc SST-400M3-72 Modules Fit in a Cold-Weather String?
Maximum series module counts for SunSpark Technology Inc SST-400M3-72 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.07 V | 10 panels | 550.7 V | 18 panels |
| -10 C (14 F) | 53.91 V | 11 panels | 593.0 V | 18 panels |
| 0 C (32 F) | 52.75 V | 11 panels | 580.2 V | 18 panels |
| 25 C (77 F STC) | 49.86 V | 12 panels | 598.3 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SST-400M3-72?
Alternative CEC solar modules from competing brands near SunSpark Technology Inc SST-400M3-72 (400.0 W), including Boviet Solar Technology Co Ltd BVM6612M-400-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H Boviet Solar Technology Co Ltd |
405.0 W | +5.0 W | 49.45 V | 20.35% | 93.3% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC Boviet Solar Technology Co Ltd |
405.0 W | +5.0 W | 49.45 V | 19.95% | 93.6% |
What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SST-400M3-72?
Evaluate SunSpark Technology Inc SST-400M3-72 (400.0 W STC, 49.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SST-400M3-72 reaches 55.07 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 424 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (424 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SST-400M3-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SunSpark Technology Inc SST-400M3-72 8 kW Residential Fit
Needs 20 modules (424 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 373.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SunSpark Technology Inc SST-400M3-72 by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is SunSpark Technology Inc SST-400M3-72 PTC wattage (373.1 W) lower than STC (400.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 373.1 W PTC (93.3% retention) across SunSpark Technology Inc SST-400M3-72's 1.97 m2 aperture.
Who should skip SunSpark Technology Inc SST-400M3-72 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 SunSpark Technology Inc SST-400M3-72 panels (424 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6612M-400-H.
What is the 1,000 V commercial string limit for SunSpark Technology Inc SST-400M3-72?
On 1,000 V commercial inverters at -10 C (53.91 V cold Voc), SunSpark Technology Inc SST-400M3-72 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SunSpark Technology Inc SST-400M3-72.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)