Skip to main content
WireAndSun
Calculators
CEC PV Module

SunSpark Technology Inc SST-400M3-72 — CEC Solar Module Specifications

Manufacturer: SunSpark Technology Inc Registry: CEC Verified Engineering Specification

SunSpark Technology Inc SST-400M3-72 is a 400.0 W STC (373.1 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.3% efficiency, 49.86 V Voc at 25 C, and 53.91 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
373.1 W
Voc @ 25C
49.86 V
Efficiency
20.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunSpark Technology Inc SST-400M3-72 Compare Against Peer CEC Listings?

How SunSpark Technology Inc SunSpark Technology Inc SST-400M3-72 handles rooftop heat (373.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SunSpark Technology Inc SST-400M3-72 exhibits 10.29 A short-circuit current, requiring a 16.05 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #9,407 of 21,677 (10.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.4 m2 for an 8 kW system (25 panels for 10 kW). Higher 49.86 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does SunSpark Technology Inc SST-400M3-72 Fall Across Listed CEC Models?

Where SunSpark Technology Inc SST-400M3-72 (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunSpark Technology Inc SST-400M3-72 (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunSpark Technolog: 400.0 W

What Dataset Percentiles Define SunSpark Technology Inc SST-400M3-72?

Percentile placement of SunSpark Technology Inc SST-400M3-72 across power density (203.0 W/m2), thermal retention, and nameplate STC wattage.

SunSpark Technology Inc SST-400M3-72 Engineering BenchmarksPercentile comparison of SunSpark Technology Inc SST-400M3-72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention93.3%Module Efficiency20.3%

What Do the Dataset Ranks Show for SunSpark Technology Inc SST-400M3-72?

Four critical engineering numbers homeowners and solar installers check first when reviewing SunSpark Technology Inc SST-400M3-72 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,359

20.3% Aperture Efficiency

Power density 203.0 W/m2 (0.39 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.91 V at -10 C (593.0 V string) and 55.07 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 39.4 m2 (424 sq ft) producing 7,462 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.86 * (1 + (-0.232/100) * (-10 - 25)) = 53.91 V | OCPD = 1.56 * 10.29 = 16.05 A

Inputs from CEC Modules.csv for SunSpark Technology Inc SST-400M3-72: Voc=49.86 V, beta_Voc=-0.232%/C, Isc=10.29 A, STC=400.0 W, Area=1.97 m2.

Result: 11 panels max on 600 V (593.0 V); 20 panels for 8 kW (424 sq ft).

What Are the Published CEC Specifications for SunSpark Technology Inc SST-400M3-72?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunSpark Technology Inc SST-400M3-72.

Official California Energy Commission (NREL SAM) test parameters for SunSpark Technology Inc SST-400M3-72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 373.1 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.86 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.29 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.18 V / 9.73 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.232 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.3% (1.97 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many SunSpark Technology Inc SST-400M3-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunSpark Technology Inc SST-400M3-72 (400.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 318 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 424 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 530 sq ft $2,503 $4,232

How Many SunSpark Technology Inc SST-400M3-72 Modules Fit in a Cold-Weather String?

Maximum series module counts for SunSpark Technology Inc SST-400M3-72 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.86V and beta_Voc=-0.232%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.07 V 10 panels 550.7 V 18 panels
-10 C (14 F) 53.91 V 11 panels 593.0 V 18 panels
0 C (32 F) 52.75 V 11 panels 580.2 V 18 panels
25 C (77 F STC) 49.86 V 12 panels 598.3 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SST-400M3-72?

Alternative CEC solar modules from competing brands near SunSpark Technology Inc SST-400M3-72 (400.0 W), including Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-W5-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 19.95% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SST-400M3-72?

Evaluate SunSpark Technology Inc SST-400M3-72 (400.0 W STC, 49.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SST-400M3-72 reaches 55.07 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 424 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (424 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SST-400M3-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunSpark Technology Inc SST-400M3-72 8 kW Residential Fit

Needs 20 modules (424 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 373.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunSpark Technology Inc SST-400M3-72 by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is SunSpark Technology Inc SST-400M3-72 PTC wattage (373.1 W) lower than STC (400.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 373.1 W PTC (93.3% retention) across SunSpark Technology Inc SST-400M3-72's 1.97 m2 aperture.

Who should skip SunSpark Technology Inc SST-400M3-72 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 SunSpark Technology Inc SST-400M3-72 panels (424 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6612M-400-H.

What is the 1,000 V commercial string limit for SunSpark Technology Inc SST-400M3-72?

On 1,000 V commercial inverters at -10 C (53.91 V cold Voc), SunSpark Technology Inc SST-400M3-72 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SunSpark Technology Inc SST-400M3-72.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.