Manufacturer: SunSpark Technology Inc Registry: CEC Verified Engineering Specification

SunSpark Technology Inc SST-385M3-72 is a 385.0 W STC (358.8 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.54% efficiency, 48.97 V Voc at 25 C, and 52.95 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
358.8 W
Voc @ 25C
48.97 V
Efficiency
19.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunSpark Technology Inc SST-385M3-72 Compare Against Peer CEC Listings?

How SunSpark Technology Inc SunSpark Technology Inc SST-385M3-72 handles rooftop heat (358.8 W PTC), 8 kW sizing, and cold winter string voltage.

SunSpark Technology Inc builds the SunSpark Technology Inc SST-385M3-72 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 195.4 W/m2 (0.37 percentage points below 19.91% CEC median). Compared against EMMVEE Photovoltaic Power Private Limited E385M72 (385.0 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Higher 48.97 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 15.79 A overcurrent floor served by a 20 A breaker.

Where Does SunSpark Technology Inc SST-385M3-72 Fall Across Listed CEC Models?

Where SunSpark Technology Inc SST-385M3-72 (385.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunSpark Technology Inc SST-385M3-72 (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunSpark Technolog: 385.0 W

What Dataset Percentiles Define SunSpark Technology Inc SST-385M3-72?

Percentile placement of SunSpark Technology Inc SST-385M3-72 across power density (195.4 W/m2), thermal retention, and nameplate STC wattage.

SunSpark Technology Inc SST-385M3-72 Engineering BenchmarksPercentile comparison of SunSpark Technology Inc SST-385M3-72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention93.2%Module Efficiency19.54%

What Do the Dataset Ranks Show for SunSpark Technology Inc SST-385M3-72?

Four critical engineering numbers homeowners and solar installers check first when reviewing SunSpark Technology Inc SST-385M3-72 specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,046

19.54% Aperture Efficiency

Power density 195.4 W/m2 (0.37 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.95 V at -10 C (582.5 V string) and 54.08 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 41.4 m2 (445 sq ft) producing 7,535 W PTC; NEC 690.8 OCPD floor is 15.79 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.97 * (1 + (-0.232/100) * (-10 - 25)) = 52.95 V | OCPD = 1.56 * 10.12 = 15.79 A

Inputs from CEC Modules.csv for SunSpark Technology Inc SST-385M3-72: Voc=48.97 V, beta_Voc=-0.232%/C, Isc=10.12 A, STC=385.0 W, Area=1.97 m2.

Result: 11 panels max on 600 V (582.5 V); 21 panels for 8 kW (445 sq ft).

What Are the Published CEC Specifications for SunSpark Technology Inc SST-385M3-72?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunSpark Technology Inc SST-385M3-72.

Official California Energy Commission (NREL SAM) test parameters for SunSpark Technology Inc SST-385M3-72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 358.8 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.97 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.12 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.28 V / 9.57 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.232 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.54% (1.97 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many SunSpark Technology Inc SST-385M3-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunSpark Technology Inc SST-385M3-72 (385.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 339 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 445 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 551 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This SunSpark Technology Inc Series?

All closely matched SunSpark Technology Inc wattages and cosmetic trims sharing the SunSpark Technology Inc SST-385M3-72 architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the SunSpark Technology Inc SST-385M3-72 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunSpark Technology Inc SST-375M3-72 375.0 W 349.2 W 48.44 V 39.74 V 19.04%
SunSpark Technology Inc SST-380M3-72 380.0 W 354.0 W 48.7 V 40.02 V 19.29%
SunSpark Technology Inc SST-385M3-72 385.0 W 358.8 W 48.97 V 40.28 V 19.54%
SunSpark Technology Inc SST-390M3-72 390.0 W 363.6 W 49.27 V 40.6 V 19.8%
SunSpark Technology Inc SST-395M3-72 395.0 W 368.3 W 49.56 V 40.89 V 20.05%

How Many SunSpark Technology Inc SST-385M3-72 Modules Fit in a Cold-Weather String?

Maximum series module counts for SunSpark Technology Inc SST-385M3-72 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.97V and beta_Voc=-0.232%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.08 V 11 panels 594.9 V 18 panels
-10 C (14 F) 52.95 V 11 panels 582.5 V 18 panels
0 C (32 F) 51.81 V 11 panels 569.9 V 19 panels
25 C (77 F STC) 48.97 V 12 panels 587.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SST-385M3-72?

Alternative CEC solar modules from competing brands near SunSpark Technology Inc SST-385M3-72 (385.0 W), including EMMVEE Photovoltaic Power Private Limited E385M72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E385M72
EMMVEE Photovoltaic Power Private Limited
385.0 W Tie (0 W) 48.9 V 19.32% 92.0%
Boviet Solar Technology Co Ltd BVM6612M-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-W5-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-385L-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.35% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SST-385M3-72?

Evaluate SunSpark Technology Inc SST-385M3-72 (385.0 W STC, 48.97 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SST-385M3-72 reaches 54.08 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (445 sq ft).
  • 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SST-385M3-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunSpark Technology Inc SST-385M3-72 8 kW Residential Fit

Needs 21 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 358.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunSpark Technology Inc SST-385M3-72 by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SunSpark Technology Inc SST-385M3-72?

Multiplying SunSpark Technology Inc SST-385M3-72's 10.12 A short-circuit current by 1.56 equals 15.79 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can SunSpark Technology Inc SST-385M3-72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.95 V cold Voc at 14 F and handles 10.12 A Isc; string inverters cap SunSpark Technology Inc SST-385M3-72 at 11 panels on 600 V.

Is SunSpark Technology Inc SST-385M3-72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunSpark Technology Inc SST-385M3-72 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.