Skip to main content
WireAndSun
Calculators
CEC PV Module

SunSpark Technology Inc SST-365M — CEC Solar Module Specifications

Manufacturer: SunSpark Technology Inc Registry: CEC Verified Engineering Specification

SunSpark Technology Inc SST-365M is a 365.0 W STC (341.9 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 18.8% efficiency, 48.2 V Voc at 25 C, and 52.06 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
341.9 W
Voc @ 25C
48.2 V
Efficiency
18.8%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunSpark Technology Inc SST-365M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SunSpark Technology Inc SST-365M (Mono-c-Si) residential solar systems.

SunSpark Technology Inc SST-365M delivers 188.0 W/m2 (1.11 percentage points below 19.91% CEC median) and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (460 sq ft). At -4 F (-20 C), string voltage climbs to 53.17 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Caterpillar Inc PVC365MP03 (365.0 W).

Where Does SunSpark Technology Inc SST-365M Fall Across Listed CEC Models?

Comparison of SunSpark Technology Inc SST-365M (365.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunSpark Technology Inc SST-365M (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunSpark Technolog: 365.0 W

What Dataset Percentiles Define SunSpark Technology Inc SST-365M?

Relative ranking of SunSpark Technology Inc SST-365M across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency.

SunSpark Technology Inc SST-365M Engineering BenchmarksPercentile comparison of SunSpark Technology Inc SST-365M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention93.7%Module Efficiency18.8%

What Do the Dataset Ranks Show for SunSpark Technology Inc SST-365M?

Summary of SunSpark Technology Inc SST-365M output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,842

18.8% Aperture Efficiency

Power density 188.0 W/m2 (1.11 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.06 V at -10 C (572.7 V string) and 53.17 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 42.7 m2 (460 sq ft) producing 7,522 W PTC; NEC 690.8 OCPD floor is 14.93 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.2 * (1 + (-0.229/100) * (-10 - 25)) = 52.06 V | OCPD = 1.56 * 9.57 = 14.93 A

Inputs from CEC Modules.csv for SunSpark Technology Inc SST-365M: Voc=48.2 V, beta_Voc=-0.229%/C, Isc=9.57 A, STC=365.0 W, Area=1.942 m2.

Result: 11 panels max on 600 V (572.7 V); 22 panels for 8 kW (460 sq ft).

What Are the Published CEC Specifications for SunSpark Technology Inc SST-365M?

Complete CEC test sheet for SunSpark Technology Inc SST-365M including Isc (9.57 A), Voc (48.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SunSpark Technology Inc SST-365M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 341.9 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.57 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.7 V / 9.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.229 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.8% (1.942 m2) Array roof footprint density
Cell Count & Technology 24 cells (Mono-c-Si) Monofacial backsheet

How Many SunSpark Technology Inc SST-365M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SunSpark Technology Inc SST-365M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 355 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 460 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 585 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This SunSpark Technology Inc Series?

Related SunSpark Technology Inc power steps and black/silver trims consolidated into this SunSpark Technology Inc SST-365M series guide.

Sibling CEC listings grouped into the SunSpark Technology Inc SST-365M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunSpark Technology Inc SST-360M 360.0 W 337.1 W 48.0 V 39.5 V 18.54%
SunSpark Technology Inc SST-365M 365.0 W 341.9 W 48.2 V 39.7 V 18.8%
SunSpark Technology Inc SST-370M 370.0 W 346.7 W 48.5 V 39.9 V 19.05%

How Many SunSpark Technology Inc SST-365M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SunSpark Technology Inc SST-365M (48.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.2V and beta_Voc=-0.229%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.17 V 11 panels 584.9 V 18 panels
-10 C (14 F) 52.06 V 11 panels 572.7 V 19 panels
0 C (32 F) 50.96 V 11 panels 560.6 V 19 panels
25 C (77 F STC) 48.2 V 12 panels 578.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SST-365M?

Four comparable CEC modules such as Caterpillar Inc PVC365MP03 (365.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC365MP03
Caterpillar Inc
365.0 W Tie (0 W) 48.13 V 19.41% 93.4%
CertainTeed CT365M10-03
CertainTeed
365.0 W Tie (0 W) 47.8 V 18.98% 91.6%
CertainTeed CT365M10-02
CertainTeed
365.0 W Tie (0 W) 47.66 V 19.39% 91.9%
CertainTeed CT365M11-02
CertainTeed
365.0 W Tie (0 W) 47.66 V 19.39% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SST-365M?

Evaluate SunSpark Technology Inc SST-365M (365.0 W STC, 48.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SST-365M reaches 53.17 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 460 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (460 sq ft).
  • 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SST-365M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunSpark Technology Inc SST-365M 8 kW Residential Fit

Needs 22 modules (460 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Caterpillar Inc PVC365MP03.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 341.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunSpark Technology Inc SST-365M by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many SunSpark Technology Inc SST-365M panels fit on a 600 V winter solar string?

At -10 C (14 F), SunSpark Technology Inc SST-365M cold Voc rises from 48.2 V to 52.06 V (beta_Voc -0.229%/C), capping a 600 V string at 11 panels (572.7 V).

How much roof area does an 8 kW array of SunSpark Technology Inc SST-365M need?

An 8 kW DC system uses 22 SunSpark Technology Inc SST-365M modules (8,030 W STC / 7,522 W PTC), covering roughly 460 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

How does SunSpark Technology Inc SST-365M compare against Caterpillar Inc PVC365MP03?

SunSpark Technology Inc SST-365M outputs 365.0 W STC (48.2 V Voc, rank #12,044 of 21,677), while Caterpillar Inc PVC365MP03 delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.